Literature DB >> 33746498

Computational Simulations for Infrared Laser Sealing and Cutting of Blood Vessels.

Nicholas C Giglio1, Nathaniel M Fried1.   

Abstract

Blood vessel burst pressures were simulated and predicted for sealing and cutting of vessels in a two-step process, using low (<25 W), medium (~100 W), and high (200 W) power lasers at a wavelength of 1470 nm. Monte Carlo optical transport, heat transfer, Arrhenius integral tissue damage simulations, and vessel pressure equations were utilized. The purpose of these studies was to first validate the numerical model by comparison with experimental results (for low and medium power) and then to use the model to simulate parameters that could not be experimentally tested (for high power). The goal was to reduce the large range of parameters (power, irradiation time, and linear beam dimensions) to be tested in future experiments, for achieving short vessel sealing/cutting times, minimal bifurcated seal zones (BSZ), and high vessel burst pressures. Blood vessels were compressed to 400 μm thickness. A wide range of linear beam profiles (1-5 mm widths and 8-9.5 mm lengths), incident powers (20-200 W) and clinically relevant irradiation times (0.5-5.0 s) were simulated and peak seal and cut temperatures as well as thermal seal zones, ablation zones, and BSZ computed. A simplistic mathematical expression was used to estimate vessel burst pressures based on seal width. Optimal low-power parameters were: 24W/5s/8×2mm (sealing) and 24W/5s/8×1mm (cutting), yielding a BSZ of 0.4 mm, corresponding to experimental burst pressures of ~450 mmHg. Optimal medium-power parameters were: 90W/1s/9.5×3mm (sealing) and 90W/1s/9.5×1mm (cutting), yielding a BSZ of 0.9 mm for burst pressures of ~1300 mmHg. Simulated only optimal high-power parameters were: 200W/0.5s/9×3 mm (sealing) and 200W/0.5s/9×1mm (cutting), yielding a BSZ of 0.9 mm and extrapolated to predict a seal strength of ~1300 mmHg. All lasers produced seal zones between 0.4-1.5 mm, corresponding to high vessel burst pressures of 300-1300 mmHg (well above normal systolic blood pressure of 120 mmHg). Higher laser powers enable shorter sealing/cutting times and higher vessel strengths.

Entities:  

Keywords:  ablation; blood vessel sealing; coagulation; laser

Year:  2020        PMID: 33746498      PMCID: PMC7978229          DOI: 10.1109/jstqe.2020.3045912

Source DB:  PubMed          Journal:  IEEE J Sel Top Quantum Electron        ISSN: 1077-260X            Impact factor:   4.653


  32 in total

1.  Optical properties of native and coagulated porcine liver tissue between 400 and 2400 nm.

Authors:  J P Ritz; A Roggan; C Isbert; G Müller; H J Buhr; C T Germer
Journal:  Lasers Surg Med       Date:  2001       Impact factor: 4.025

2.  Light dosimetry: effects of dehydration and thermal damage on the optical properties of the human aorta.

Authors:  I F Cilesiz; A J Welch
Journal:  Appl Opt       Date:  1993-02-01       Impact factor: 1.980

3.  Rapid sealing and cutting of porcine blood vessels, ex vivo, using a high-power, 1470-nm diode laser.

Authors:  Nicholas C Giglio; Thomas C Hutchens; William C Perkins; Cassandra Latimer; Arlen Ward; William H Nau; Nathaniel M Fried
Journal:  J Biomed Opt       Date:  2014-03       Impact factor: 3.170

4.  Temperature safety profile of laparoscopic devices: Harmonic ACE (ACE), Ligasure V (LV), and plasma trisector (PT).

Authors:  F J Kim; M F Chammas; E Gewehr; M Morihisa; F Caldas; E Hayacibara; M Baptistussi; F Meyer; A C Martins
Journal:  Surg Endosc       Date:  2007-11-20       Impact factor: 4.584

5.  A dynamic photo-thermal model of carbon dioxide laser tissue ablation.

Authors:  J Z Zhang; Y G Shen; X X Zhang
Journal:  Lasers Med Sci       Date:  2008-06-07       Impact factor: 3.161

6.  Studies of thermal injury; the predictability and the significance of thermally induced rate processes leading to irreversible epidermal injury.

Authors:  F C HENRIQUES
Journal:  Arch Pathol (Chic)       Date:  1947-05

7.  Perpendicular blood vessel seals are stronger than those made at an angle.

Authors:  Aaron C Voegele; Donna L Korvick; Mario Gutierrez; Jeffrey W Clymer; Joseph F Amaral
Journal:  J Laparoendosc Adv Surg Tech A       Date:  2013-06-11       Impact factor: 1.878

8.  Studies of Thermal Injury: III. The Pathology and Pathogenesis of Cutaneous Burns. An Experimental Study.

Authors:  A R Moritz
Journal:  Am J Pathol       Date:  1947-11       Impact factor: 4.307

9.  A three-zone model of soft-tissue damage by a CO2 laser.

Authors:  A L McKenzie
Journal:  Phys Med Biol       Date:  1986-09       Impact factor: 3.609

10.  Laparoscopic splenectomy: ligasure versus EndoGIA: a comparative study.

Authors:  Fabrizio Romano; Roberta Gelmini; Roberto Caprotti; Alessia Andreotti; Marcello Guaglio; Chiara Franzoni; Franco Uggeri; Massimo Saviano
Journal:  J Laparoendosc Adv Surg Tech A       Date:  2007-12       Impact factor: 1.878

View more
  4 in total

1.  Reciprocating Side-Firing Fiber for Laser Sealing of Blood Vessels.

Authors:  Nicholas C Giglio; Haleigh M Grose; Nathaniel M Fried
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2022-03-03

2.  Optical Coherence Tomography Feedback System for Infrared Laser Sealing of Blood Vessels.

Authors:  Nicholas C Giglio; Haleigh M Grose; Nathaniel M Fried
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2022-03-07

3.  Laser coagulation and hemostasis of large diameter blood vessels: effect of shear stress and flow velocity.

Authors:  Nitesh Katta; Daniel Santos; Austin B McElroy; Arnold D Estrada; Glori Das; Mohammad Mohsin; Moses Donovan; Thomas E Milner
Journal:  Sci Rep       Date:  2022-05-19       Impact factor: 4.996

4.  Nondestructive optical feedback systems for use during infrared laser sealing of blood vessels.

Authors:  Nicholas C Giglio; Nathaniel M Fried
Journal:  Lasers Surg Med       Date:  2022-04-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.