Literature DB >> 35950053

Optical Coherence Tomography Feedback System for Infrared Laser Sealing of Blood Vessels.

Nicholas C Giglio1, Haleigh M Grose2, Nathaniel M Fried1.   

Abstract

Infrared (IR) lasers have recently been tested as an alternative to electrosurgical and ultrasonic laparoscopic devices for optical sealing of blood vessels. IR laser technology previously demonstrated faster sealing times, reduced thermal spread, and lower device temperatures during experimental studies. However, current commercial laparoscopic devices incorporate electrical impedance and/or temperature sensors as real-time, closed-loop, feedback to indicate successful blood vessel seals. This preliminary study explores an infrared laser system for sealing and optical coherence tomography (OCT) as a potential feedback system for successful vessel seal verification. A 1470-nm diode laser delivered an incident power of 30 W for an irradiation time of 5 s using an 8 × 2 mm linear beam, for creating strong seals in porcine renal blood vessels under compression. After sealing the blood vessels, OCT was performed on unsealed and sealed vessel regions for comparison. Standard vessel burst pressure (BP) measurements confirmed successful seals after OCT. Integrated reflectance intensity in OCT A-scans decreased by an average of 20 ± 6% in sealed versus native vessels of 2.4 ± 0.4 mm diameter. Vessel BP measured 532 ± 239 mmHg, with all vessels (n = 25) recording a successful BP > 180 mmHg (hypertensive blood pressure). Unsealed vessels demonstrated significantly deeper imaging marked by a continuous decay in reflected intensity, while sealed vessels showed subsurface reflectance intensity peaks, immediately followed by a rapid decay in reflectance intensity. These markers are consistent with increased light scattering and decreased optical penetration depth upon thermal coagulation of tissues. A-line OCT data consistently differentiated between sealed and unsealed blood vessel regions. Future work will involve OCT integration into the laparoscopic device for real-time optical feedback during IR laser sealing.

Entities:  

Keywords:  blood vessel; burst pressures; coagulation; compression; laser; optical coherence tomography

Year:  2022        PMID: 35950053      PMCID: PMC9361300          DOI: 10.1117/12.2612035

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  13 in total

1.  Light dosimetry: effects of dehydration and thermal damage on the optical properties of the human aorta.

Authors:  I F Cilesiz; A J Welch
Journal:  Appl Opt       Date:  1993-02-01       Impact factor: 1.980

2.  Infrared laser sealing of porcine vascular tissues using a 1,470 nm diode laser: Preliminary in vivo studies.

Authors:  Christopher M Cilip; Duane Kerr; Cassandra A Latimer; Sarah B Rosenbury; Nicholas C Giglio; Thomas C Hutchens; William H Nau; Nathaniel M Fried
Journal:  Lasers Surg Med       Date:  2016-10-27       Impact factor: 4.025

3.  Rapid sealing of porcine renal blood vessels, ex vivo, using a high power, 1470-nm laser, and laparoscopic prototype.

Authors:  Luke A Hardy; Thomas C Hutchens; Eric R Larson; David A Gonzalez; Chun-Hung Chang; William H Nau; Nathaniel M Fried
Journal:  J Biomed Opt       Date:  2017-05-01       Impact factor: 3.170

4.  Infrared laser thermal fusion of blood vessels: preliminary ex vivo tissue studies.

Authors:  Christopher M Cilip; Sarah B Rosenbury; Nicholas Giglio; Thomas C Hutchens; Gino R Schweinsberger; Duane Kerr; Cassandra Latimer; William H Nau; Nathaniel M Fried
Journal:  J Biomed Opt       Date:  2013-05       Impact factor: 3.170

5.  High-burst-strength, feedback-controlled bipolar vessel sealing.

Authors:  J S Kennedy; P L Stranahan; K D Taylor; J G Chandler
Journal:  Surg Endosc       Date:  1998-06       Impact factor: 4.584

6.  Optical coherence tomography for use in infrared laser sealing of blood vessels.

Authors:  Nicholas C Giglio; Thomas C Hutchens; Christopher M Cilip; Nathaniel M Fried
Journal:  IEEE Photonics Conf       Date:  2020-11-16

7.  A new tissue-sealing technique using the Ligasure system for nonanatomical pulmonary resection: preliminary results of sutureless and stapleless thoracoscopic surgery.

Authors:  Norihisa Shigemura; Akinori Akashi; Tomoyuki Nakagiri; Mitsunori Ohta; Hikaru Matsuda
Journal:  Ann Thorac Surg       Date:  2004-04       Impact factor: 4.330

8.  Use of 2D images of depth and integrated reflectivity to represent the severity of demineralization in cross-polarization optical coherence tomography.

Authors:  Kenneth H Chan; Andrew C Chan; William A Fried; Jacob C Simon; Cynthia L Darling; Daniel Fried
Journal:  J Biophotonics       Date:  2013-12-05       Impact factor: 3.207

9.  Computational Simulations for Infrared Laser Sealing and Cutting of Blood Vessels.

Authors:  Nicholas C Giglio; Nathaniel M Fried
Journal:  IEEE J Sel Top Quantum Electron       Date:  2020-12-18       Impact factor: 4.653

10.  Doppler optical coherence tomography for energy seal evaluation and comparison to visual evaluation.

Authors:  Andrew Marques; Robnier Reyes; Christopher R Pasarikovski; Chaoliang Chen; Joel Ramjist; Xijia Gu; Victor Yang
Journal:  J Biomed Opt       Date:  2020-03       Impact factor: 3.170

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.