Literature DB >> 33733281

Comparison of refractive outcomes using Scheimpflug Holladay equivalent keratometry or IOLMaster 700 keratometry for IOL power calculation.

Mustafa Aksoy1, Leyla Asena2, Sirel Gür Güngör2, Ali Küçüködük2, Ahmet Akman2.   

Abstract

PURPOSE: This study aims to compare postoperative refractive error results using Pentacam (Oculus Optikgeräte GmbH) Holladay equivalent keratometry readings (EKR) or IOLMaster 700 (Carl Zeiss Meditec AG) keratometry (K) values in IOL power calculation.
MATERIAL AND METHODS: This retrospective study included 54 eyes of 31 patients who underwent cataract surgery. Preoperative biometric measurements of all patients were obtained using IOLMaster 700 followed by Pentacam measurements. IOLMaster 700 K measurements on horizontal (K1) and vertical (K2) axes and EKR measurements on 2 mm (EKR2mm), 3 mm (EKR3mm) and 4.5 mm (EKR4.5 mm) corneal zones were recorded. EKR4.5 mm value and IOLMaster 700 K values were used in Holladay-II, SRK/T, Haigis, and Hoffer-Q formulas to calculate predictive refractive error (PRE). Absolute refractive error (ARE) was calculated as the absolute difference between actual postoperative refractive error (APRE) and PRE values.
RESULTS: Mean age was 72.2 ± 8.3 (51-87) years and mean IOL power was 21.5 ± 2.9 D (18-23 D). There was no significant difference between PRE values when IOLMaster 700 K measurements and EKR4.5 mm K measurements were used in Holladay-II, SRK/T, Haigis, and Hoffer-Q formulas (p = 0.571, p = 0.833, p = 0.165, p = 0.347, respectively). There was no significant difference between APRE and ARE values (p = 0.124). According to mean ARE results, the closest estimate was achieved when the IOLMaster 700 K values were used in the Holladay-II formula (p = 0.271).
CONCLUSION: IOLMaster 700 K measurement and Pentacam EKR4.5 mm measurements can be used interchangeably. IOLMaster 700 K values yielded the most predictive measurement of the refractive result using the Holladay-II formula.

Entities:  

Keywords:  Cataract surgery; Equivalent keratometry readings; IOLMaster 700; Optical Biometry; Pentacam

Mesh:

Year:  2021        PMID: 33733281     DOI: 10.1007/s10792-021-01781-6

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  2 in total

1.  Optical biometry intraocular lens power calculation using different formulas in patients with different axial lengths.

Authors:  Jia-Kang Wang; Shu-Wen Chang
Journal:  Int J Ophthalmol       Date:  2013-04-18       Impact factor: 1.779

2.  Reliability of a New Swept-Source Optical Coherence Tomography Biometer in Healthy Children, Adults, and Cataract Patients.

Authors:  Jinhai Huang; Yuyu Zhao; Giacomo Savini; Guanshun Yu; Jinjin Yu; Zhongxing Chen; Ruixue Tu; Yune Zhao
Journal:  J Ophthalmol       Date:  2020-05-15       Impact factor: 1.909

  2 in total
  3 in total

1.  Comparison of Total Corneal Astigmatism between IOLMaster and Pentacam.

Authors:  Xiaochun Li; Xiaoguang Cao; Yongzhen Bao
Journal:  Biomed Res Int       Date:  2022-07-08       Impact factor: 3.246

2.  Application of total keratometry in ten intraocular lens power calculation formulas in highly myopic eyes.

Authors:  Ling Wei; Kaiwen Cheng; Wenwen He; Xiangjia Zhu; Yi Lu
Journal:  Eye Vis (Lond)       Date:  2022-06-09

3.  Group-Based Trajectory Modeling to Identify Factors Influencing the Development of Myopia in Patients Receiving Orthokeratology.

Authors:  Chunyu Duan; Fan Feng; Lijuan Liu; Fang Qu; Zhiye Yang; Hui Zhang; Chunguang Jiang
Journal:  Int J Gen Med       Date:  2022-04-18
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.