Purpose: Coronary artery calcium (CAC) scoring with computed tomography (CT) has been proposed as a screening tool for coronary artery disease, but concerns remain regarding the radiation dose of CT CAC scoring. Photon counting detectors and iterative reconstruction (IR) are promising approaches for patient dose reduction, yet the preservation of CAC scores with IR has been questioned. The purpose of this study was to investigate the applicability of IR for quantification of CAC using a photon counting flat-detector. Approach: We imaged a cardiac rod phantom with calcium hydroxyapatite (CaHA) inserts with different noise levels using an experimental photon counting flat-detector CT setup to simulate the clinical CAC scoring protocol. We applied filtered back projection (FBP) and two IR algorithms with different regularization strengths. We compared the air kerma values, image quality parameters [noise magnitude, noise power spectrum, modulation transfer function (MTF), and contrast-to-noise ratio], and CaHA quantification accuracy between FBP and IR.
Results: IR regularization strength influenced CAC scores significantly ( p < 0.05 ). The CAC volumes and scores between FBP and IRs were the most similar when the IR regularization strength was chosen to match the MTF of the FBP reconstruction.
Conclusion: When the regularization strength is selected to produce comparable spatial resolution with FBP, IR can yield comparable CAC scores and volumes with FBP. Nonetheless, at the lowest radiation dose setting, FBP produced more accurate CAC volumes and scores compared to IR, and no improved CAC scoring accuracy at low dose was demonstrated with the utilized IR methods.
© 2021 The Authors.

Entities:  

Keywords:  computed tomography; coronary artery calcium; image quality; iterative reconstruction; phantom study; photon counting flat-detector

Year:  2021        PMID: 33718518      PMCID: PMC7946398          DOI: 10.1117/1.JMI.8.5.052102

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  50 in total

Review 1.  Vision 20/20: Single photon counting x-ray detectors in medical imaging.

Authors:  Katsuyuki Taguchi; Jan S Iwanczyk
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

2.  Iterative reconstruction techniques for computed tomography part 2: initial results in dose reduction and image quality.

Authors:  Martin J Willemink; Tim Leiner; Pim A de Jong; Linda M de Heer; Rutger A J Nievelstein; Arnold M R Schilham; Ricardo P J Budde
Journal:  Eur Radiol       Date:  2013-01-16       Impact factor: 5.315

3.  Advanced modelled iterative reconstruction for abdominal CT: qualitative and quantitative evaluation.

Authors:  S Gordic; L Desbiolles; P Stolzmann; L Gantner; S Leschka; D B Husarik; H Alkadhi
Journal:  Clin Radiol       Date:  2014-09-18       Impact factor: 2.350

4.  Assessment of a photon-counting detector for a dual-energy C-arm angiographic system.

Authors:  Moiz Ahmad; Rebecca Fahrig; Leland Pung; Martin Spahn; Niko S Köster; Silke Reitz; Teri Moore; Jang-Hwan Choi; Waldo Hinshaw; Yan Xia; Kerstin Müller
Journal:  Med Phys       Date:  2017-09-22       Impact factor: 4.071

5.  Dose Efficiency of Quarter-Millimeter Photon-Counting Computed Tomography: First-in-Human Results.

Authors:  Amir Pourmorteza; Rolf Symons; André Henning; Stefan Ulzheimer; David A Bluemke
Journal:  Invest Radiol       Date:  2018-06       Impact factor: 6.016

6.  Reproducibility of the measurement of coronary calcium with ultrafast computed tomography.

Authors:  S Devries; C Wolfkiel; V Shah; E Chomka; S Rich
Journal:  Am J Cardiol       Date:  1995-05-01       Impact factor: 2.778

7.  Photon-Counting Computed Tomography for Vascular Imaging of the Head and Neck: First In Vivo Human Results.

Authors:  Rolf Symons; Daniel S Reich; Mohammadhadi Bagheri; Tyler E Cork; Bernhard Krauss; Stefan Ulzheimer; Steffen Kappler; David A Bluemke; Amir Pourmorteza
Journal:  Invest Radiol       Date:  2018-03       Impact factor: 6.016

8.  Iterative image reconstruction techniques for CT coronary artery calcium quantification: comparison with traditional filtered back projection in vitro and in vivo.

Authors:  Andreas Schindler; Rozemarijn Vliegenthart; U Joseph Schoepf; Philipp Blanke; Ullrich Ebersberger; Young Jun Cho; Thomas Allmendinger; Sebastian Vogt; Rainer Raupach; Christian Fink; Tobias Saam; Fabian Bamberg; Konstantin Nikolaou; Paul Apfaltrer
Journal:  Radiology       Date:  2013-11-06       Impact factor: 11.105

Review 9.  Low Radiation Dose Calcium Scoring: Evidence and Techniques.

Authors:  Kaitlin B Baron; Andrew D Choi; Marcus Y Chen
Journal:  Curr Cardiovasc Imaging Rep       Date:  2016-03-02

10.  Spectral Photon-Counting Computed Tomography (SPCCT): in-vivo single-acquisition multi-phase liver imaging with a dual contrast agent protocol.

Authors:  Salim Si-Mohamed; Valérie Tatard-Leitman; Alexis Laugerette; Monica Sigovan; Daniela Pfeiffer; Ernst J Rummeny; Philippe Coulon; Yoad Yagil; Philippe Douek; Loic Boussel; Peter B Noël
Journal:  Sci Rep       Date:  2019-06-11       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.