Prediction of the severity of aortic stenosis by Doppler aortic valve area determination: prospective Doppler-catheterization correlation in 100 patients.

J K Oh1, C P Taliercio, D R Holmes, G S Reeder, K R Bailey, J B Seward, A J Tajik.   

Abstract

Two-dimensional and Doppler echocardiography was performed prospectively in 100 patients with aortic stenosis who were undergoing clinically indicated cardiac catheterization. The purpose of this study procedure was to determine various Doppler variables predictive of the severity of aortic stenosis and to compare Doppler- and catheterization-derived aortic valve areas. Doppler-derived mean gradient correlated well with corresponding gradient by catheterization (r = 0.86). Peak Doppler aortic flow velocity greater than or equal to 4.5 m/s and Doppler-derived mean aortic gradient greater than or equal to 50 mm Hg were specific (93 and 94%, respectively) for severe aortic stenosis (defined as catheterization-derived aortic valve area less than or equal to 0.75 cm2) but were not sensitive (44 and 48%, respectively). Doppler-derived aortic valve area calculated by the continuity equation correlated well with catheterization-derived aortic valve area calculated by the Gorlin equation when either the time-velocity integral ratio (r = 0.83) or the peak flow velocity ratio (r = 0.80) between the left ventricular outflow tract and the aortic valve was used in the continuity equation. A velocity ratio of less than or equal to 0.25 alone was sensitive (92%) in detecting severe aortic stenosis. Therefore, use of various Doppler-derived values allows reliable noninvasive estimation of the severity of aortic stenosis.

Entities:  

Mesh:

Year:  1988        PMID: 3366997     DOI: 10.1016/0735-1097(88)90286-0

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  50 in total

Review 1.  [Echocardiographic evaluation in unoperated congenital heart disease in adults].

Authors:  A Geibel
Journal:  Herz       Date:  1999-06       Impact factor: 1.443

Review 2.  Calcific aortic stenosis: from bench to the bedside--emerging clinical and cellular concepts.

Authors:  Nalini M Rajamannan; Bernard Gersh; Robert O Bonow
Journal:  Heart       Date:  2003-07       Impact factor: 5.994

3.  Continuity equation and Gorlin formula compared with directly observed orifice area in native and prosthetic aortic valves.

Authors:  J B Chambers; D C Sprigings; T Cochrane; J Allen; R Morris; M M Black; G Jackson
Journal:  Br Heart J       Date:  1992-02

4.  Aortic stenosis: the spectrum of practice.

Authors:  O Khalid; D M Luxenberg; C Sable; O Benavidez; T Geva; B Hanna; R Abdulla
Journal:  Pediatr Cardiol       Date:  2006-11-16       Impact factor: 1.655

5.  Discrepancy between Doppler and catheter measurements of pressure gradients across small-size prosthetic valve.

Authors:  Takuya Yamashita; Yukinori Moriyama; Naoyuki Sata; Naokazu Hamada; Takashi Horinouchi; Shigeru Amitani; Kenkichi Miyahara; Kentaro Setoyama; Kazuhiro Misumi; Hiroshi Sakamoto
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2005-02

6.  Is it time for medical therapy for aortic valve disease?

Authors:  Nalini M Rajamannan
Journal:  Expert Rev Cardiovasc Ther       Date:  2004-11

Review 7.  Pathophysiology of Aortic Valve Stenosis: Is It Both Fibrocalcific and Sex Specific?

Authors:  Yoginee Sritharen; Maurice Enriquez-Sarano; Hartzell V Schaff; Grace Casaclang-Verzosa; Jordan D Miller
Journal:  Physiology (Bethesda)       Date:  2017-05

Review 8.  Challenges in Aortic Valve Stenosis: Low-Flow States Diagnosis, Management, and a Review of the Current Literature.

Authors:  Matthew W Sherwood; Todd L Kiefer
Journal:  Curr Cardiol Rep       Date:  2017-10-30       Impact factor: 2.931

Review 9.  Workup and Management of Patients With Paradoxical Low-Flow, Low-Gradient Aortic Stenosis.

Authors:  Mohamed-Salah Annabi; Marine Clisson; Marie-Annick Clavel; Philippe Pibarot
Journal:  Curr Treat Options Cardiovasc Med       Date:  2018-05-02

10.  Flow-gradient patterns in severe aortic stenosis with preserved ejection fraction: clinical characteristics and predictors of survival.

Authors:  Mackram F Eleid; Paul Sorajja; Hector I Michelena; Joseph F Malouf; Christopher G Scott; Patricia A Pellikka
Journal:  Circulation       Date:  2013-09-18       Impact factor: 29.690

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.