Literature DB >> 33653318

Root canal curvature as a prognostic factor influencing the diagnostic accuracy of radiographic working length determination and postoperative canal axis modification: an in vitro comparative study.

Bestoon Mohammed Faraj1.   

Abstract

BACKGROUND: Radiographic analysis of tooth morphology is mandatory for accurate calibration of the degree of canal curvature angle and radiographic working length to its real dimensions in case difficulty assessment protocols. This study aimed to determine the impact of the degree of root canal curvature angle on maintaining the real working length and the original canal axis of prepared root canals using a reciprocating rotary instrumentation technique.
METHODS: Radiographic image analysis was performed on 60 extracted single-rooted human premolar teeth with a moderate canal curvature (10°-25°) and severe canal curvature (26°-70°). Working length and longitudinal canal axis were determined using cone-beam computed tomography (CBCT) and digital periapical radiography. The real canal length was determined by subtracting 0.5 mm from the actual canal length. Root canals were prepared using the WaveOne Gold reciprocating file (Dentsply Maillefer, Ballaigues, Switzerland).
RESULTS: There was no significant relation of the degree of canal curvature angle to the accuracy of radiographic working length estimated on CBCT and digital periapical radiographic techniques (P > 0.05). Postinstrumentation changes in the original canal axis between moderate and severe canal curvature angles, assessed on CBCT and periapical digital radiographic images were statistically non-significant (P > 0.05).
CONCLUSIONS: A standardized digital periapical radiographic method performed similarly to the CBCT technique near to its true working length. No significant interaction exists between the diagnostic working length estimation, postoperative root canal axis modification, and the degree of canal curvature angle, using reciprocating rotary instrumentation technique.

Entities:  

Keywords:  Canal axis; Canal curvature; Cone‐beam computed tomography; Digital periapical image; Real canal length

Year:  2021        PMID: 33653318      PMCID: PMC7923826          DOI: 10.1186/s12903-021-01446-x

Source DB:  PubMed          Journal:  BMC Oral Health        ISSN: 1472-6831            Impact factor:   2.757


  42 in total

Review 1.  Current Assessment of Reciprocation in Endodontic Preparation: A Comprehensive Review-Part I: Historic Perspectives and Current Applications.

Authors:  Nicola Maria Grande; Hany Mohamed Aly Ahmed; Stephen Cohen; Frédéric Bukiet; Gianluca Plotino
Journal:  J Endod       Date:  2015-11       Impact factor: 4.171

2.  Comparative Analysis of Canal Centering Ability of Different Single File Systems Using Cone Beam Computed Tomography- An In-Vitro Study.

Authors:  Rolly S Agarwal; Jatin Agarwal; Pradeep Jain; Anil Chandra
Journal:  J Clin Diagn Res       Date:  2015-05-01

3.  Accuracy of endodontic working length determination using cone beam computed tomography.

Authors:  T Connert; M Hülber-J; A Godt; C Löst; A ElAyouti
Journal:  Int Endod J       Date:  2013-11-15       Impact factor: 5.264

4.  A micro-computed tomographic evaluation of apical root canal preparation using three instrumentation techniques.

Authors:  J Moore; P Fitz-Walter; P Parashos
Journal:  Int Endod J       Date:  2009-12       Impact factor: 5.264

5.  Canal Transportation and Centering Ability of WaveOne Gold in Combination with and without Different Glide Path Techniques.

Authors:  Martin Vorster; Peet J van der Vyver; Farzana Paleker
Journal:  J Endod       Date:  2018-08-02       Impact factor: 4.171

6.  Canal transportation and centering ratio after preparation in severely curved canals: analysis by micro-computed tomography and double-digital radiography.

Authors:  Ane Poly; Fouad AlMalki; Fernando Marques; Bekir Karabucak
Journal:  Clin Oral Investig       Date:  2019-03-05       Impact factor: 3.573

7.  Comparative evaluation of the shaping ability of WaveOne, Reciproc and OneShape single-file systems in severely curved root canals of extracted teeth.

Authors:  S E D M Saber; M M Nagy; E Schäfer
Journal:  Int Endod J       Date:  2014-04-18       Impact factor: 5.264

8.  Comparative evaluation of the canal curvature modifications after instrumentation with One Shape rotary and Wave One reciprocating files.

Authors:  Anil Dhingra; Rohit Kochar; Satyabrat Banerjee; Punit Srivastava
Journal:  J Conserv Dent       Date:  2014-03

9.  Root form and canal morphology of maxillary first premolars of a Yemeni population.

Authors:  Elham M Senan; Hatem A Alhadainy; Thuraia M Genaid; Ahmed A Madfa
Journal:  BMC Oral Health       Date:  2018-05-31       Impact factor: 2.757

10.  Comparative analysis of canal-centering ratio, apical transportation, and remaining dentin thickness between single-file systems, i.e., OneShape and WaveOne reciprocation: An in vitro study.

Authors:  Aditi Jain; Asmita Singh Gupta; Rupika Agrawal
Journal:  J Conserv Dent       Date:  2018 Nov-Dec
View more