Literature DB >> 26155551

Comparative Analysis of Canal Centering Ability of Different Single File Systems Using Cone Beam Computed Tomography- An In-Vitro Study.

Rolly S Agarwal1, Jatin Agarwal2, Pradeep Jain3, Anil Chandra4.   

Abstract

BACKGROUND: The ability of an endodontic instrument to remain centered in the root canal system is one of the most important characteristic influencing the clinical performance of a particular file system. Thus, it is important to assess the canal centering ability of newly introduced single file systems before they can be considered a viable replacement of full-sequence rotary file systems. AIM: The aim of the study was to compare the canal transportation, centering ability, and time taken for preparation of curved root canals after instrumentation with single file systems One Shape and Wave One, using cone-beam computed tomography (CBCT).
MATERIALS AND METHODS: Sixty mesiobuccal canals of mandibular molars with an angle of curvature ranging from 20(o) to 35(o) were divided into three groups of 20 samples each: ProTaper PT (group I) - full-sequence rotary control group, OneShape OS (group II)- single file continuous rotation, WaveOne WO - single file reciprocal motion (group III). Pre instrumentation and post instrumentation three-dimensional CBCT images were obtained from root cross-sections at 3mm, 6mm and 9mm from the apex. Scanned images were then accessed to determine canal transportation and centering ability. The data collected were evaluated using one-way analysis of variance (ANOVA) with Tukey's honestly significant difference test.
RESULTS: It was observed that there were no differences in the magnitude of transportation between the rotary instruments (p >0.05) at both 3mm as well as 6mm from the apex. At 9 mm from the apex, Group I PT showed significantly higher mean canal transportation and lower centering ability (0.19±0.08 and 0.39±0.16), as compared to Group II OS (0.12±0.07 and 0.54±0.24) and Group III WO (0.13±0.06 and 0.55±0.18) while the differences between OS and WO were not statistically significant.
CONCLUSION: It was concluded that there was minor difference between the tested groups. Single file systems demonstrated average canal transportation and centering ability comparable to full sequence Protaper system in curved root canals.

Entities:  

Keywords:  CBCT; Canal transportation; Centering ability; Single file system

Year:  2015        PMID: 26155551      PMCID: PMC4484143          DOI: 10.7860/JCDR/2015/12097.5863

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  31 in total

1.  Efficiency of rotary nickel-titanium K3 instruments compared with stainless steel hand K-Flexofile. Part 1. Shaping ability in simulated curved canals.

Authors:  E Schäfer; H Florek
Journal:  Int Endod J       Date:  2003-03       Impact factor: 5.264

2.  Lifespan of one nickel-titanium rotary file with reciprocating motion in curved root canals.

Authors:  Sung-Yeop You; Kwang-Shik Bae; Seung-Ho Baek; Kee-Yeon Kum; Won-Jun Shon; Woocheol Lee
Journal:  J Endod       Date:  2010-12       Impact factor: 4.171

3.  A micro-computed tomography-based comparison of the canal transportation and centering ability of ProTaper Universal rotary and WaveOne reciprocating files.

Authors:  Blake McRay; Timothy C Cox; Nestor Cohenca; James D Johnson; Avina Paranjpe
Journal:  Quintessence Int       Date:  2014-02       Impact factor: 1.677

4.  Curved canals: ancestral files revisited.

Authors:  Nidhi Jain; Suneja Tushar
Journal:  Indian J Dent Res       Date:  2008 Jul-Sep

5.  In vitro canal and isthmus debris removal of the self-adjusting file, K3, and WaveOne files in the mesial root of human mandibular molars.

Authors:  Matthew A Dietrich; Timothy C Kirkpatrick; John M Yaccino
Journal:  J Endod       Date:  2012-08       Impact factor: 4.171

6.  Use of cone beam computed tomography in endodontics.

Authors:  William C Scarfe; Martin D Levin; David Gane; Allan G Farman
Journal:  Int J Dent       Date:  2010-03-31

7.  Canal-centering ability: An endodontic challenge.

Authors:  Deivanayagam Kandaswamy; Nagendrababu Venkateshbabu; Ilango Porkodi; Gali Pradeep
Journal:  J Conserv Dent       Date:  2009-01

8.  The ability of different nickel-titanium rotary instruments to induce dentinal damage during canal preparation.

Authors:  Carlos Alexandre Souza Bier; Hagay Shemesh; Mário Tanomaru-Filho; Paul R Wesselink; Min-Kai Wu
Journal:  J Endod       Date:  2008-12-12       Impact factor: 4.171

9.  A comparative assessment of fracture resistance of endodontically treated and re-treated teeth: An in vitro study.

Authors:  Arathi Ganesh; Nagendrababu Venkateshbabu; Aby John; Gogulnath Deenadhayalan; Deivanayagam Kandaswamy
Journal:  J Conserv Dent       Date:  2014-01

10.  Evaluation of the root and canal morphology of mandibular permanent molars in a south-eastern Turkish population using cone-beam computed tomography.

Authors:  Bilge Gulsum Nur; Evren Ok; Mustafa Altunsoy; Osman Sami Aglarci; Mehmet Colak; Enes Gungor
Journal:  Eur J Dent       Date:  2014-04
View more
  7 in total

1.  Comparative Assessment of Canal Transportation and Centering Ability of Reciproc and One Shape File Systems Using CBCT-An In Vitro Study.

Authors:  Anika Mittal; Shifali Dadu; Neetu Sharma Singh; Sarita Singh; Bhupesh Gupta; Anju Abraham; Bidya Yendrembam; Shilpa Kumari
Journal:  J Clin Diagn Res       Date:  2017-04-01

2.  Cone-Beam Computed Tomography Assessment of Canal-Centering Ability for Traditionally Used Nickel Titanium and Nickel Titanium Files with Reciprocating Hand Piece and Wave-One Files.

Authors:  Rubeena Tabasum Shaik; Satyanarayana V V Uppalapati; Lavanya Neelima Uppu; Sriramarao Sudhamsetty; D Praneeth Kumar; Maheswari Kumpatla
Journal:  J Pharm Bioallied Sci       Date:  2021-06-05

3.  CBCT Assessment of Root Dentine Removal by Gates-Glidden Drills and Two Engine-Driven Root Preparation Systems.

Authors:  Azade Harandi; Fatemeh Mohammadpour Maleki; Ehsan Moudi; Maryam Ehsani; Soraya Khafri
Journal:  Iran Endod J       Date:  2017

4.  Comparison of Shaping Ability of Different Single-File Systems Using Microcomputed Tomography.

Authors:  Mohamed Mohamed Elashiry; Shehab Eldin Saber; Salma Hasan Elashry
Journal:  Eur J Dent       Date:  2020-01-31

5.  Estimation Accuracy of Root Canal Curvatures from Different Dental Diagnostic Imaging Techniques: An In Vitro Experimental Study.

Authors:  Bestoon Mohammed Faraj
Journal:  Biomed Res Int       Date:  2021-01-13       Impact factor: 3.411

6.  Root canal curvature as a prognostic factor influencing the diagnostic accuracy of radiographic working length determination and postoperative canal axis modification: an in vitro comparative study.

Authors:  Bestoon Mohammed Faraj
Journal:  BMC Oral Health       Date:  2021-03-02       Impact factor: 2.757

7.  Preoperative Estimation of Endodontic Working Length with Cone-Beam Computed Tomography and Standardized Paralleling Technique in comparison to Its Real Length.

Authors:  Bestoon Mohammed Faraj
Journal:  Biomed Res Int       Date:  2020-10-10       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.