Literature DB >> 30078574

Canal Transportation and Centering Ability of WaveOne Gold in Combination with and without Different Glide Path Techniques.

Martin Vorster1, Peet J van der Vyver1, Farzana Paleker2.   

Abstract

INTRODUCTION: The aim of this study was to compare centering ability and transportation values of the Primary WaveOne Gold (PWOG; Dentsply Sirona, Ballaigues, Switzerland) instrument with or without different glide path techniques. Centering ability and transportation were also compared between the 3 different glide path preparation groups.
METHODS: The mesiobuccal canals of 60 extracted human mandibular molars (curvature angles between 25° and 35° and radii ≤10 mm) were selected and randomly divided into 4 groups with 15 canals each. Canals were negotiated to patency with a #8 K-file. Canal preparations were performed by a single operator using precurved #10, 15, and 20 stainless steel manual K-files (group KF); a #10 stainless steel manual K-file followed by PathFiles #1-3 (Dentsply Sirona) (group PF); a #10 stainless steel manual K-file followed by the WaveOne Gold Glider (Dentsply Sirona) (group WOGG); and no further glide path preparation (group NG). Micro-computed tomographic imaging was used to scan teeth before and after glide path preparation. The final canal preparation was performed with PWOG; after which, all 60 specimens were scanned again using micro-computed tomographic imaging. Canal transportation and centering ratio values were determined over levels 3 mm, 5 mm, and 7 mm from the root apex after glide path preparation and again after final preparation with PWOG. One-way analysis of variance was used to statistically compare groups. The significance level was set at P < .05.
RESULTS: No statistically significant difference in the mean centering ratios was found after glide path preparation when the KF, PF, and WOGG groups were compared (P > .05). The mean combined transportation values after glide path preparation were statistically significantly higher in the KF group compared with the PF and WOGG groups (P > .05). There was no statistically significant difference in the mean combined centering ratios or transportation values of the NG and 3 glide path groups in combination with PWOG over the 3 levels (P > .05).
CONCLUSION: KF group showed the highest mean transportation values during glide path preparation. However, the PWOG instrument's performance regarding centering ability and transportation was not influenced by the different glide path/no glide path preparation groups.
Copyright © 2018 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Canal transportation; PathFiles; WaveOne Gold; WaveOne Gold Glider; centering ability; micro–computed tomography; stainless steel K-files

Mesh:

Substances:

Year:  2018        PMID: 30078574     DOI: 10.1016/j.joen.2018.06.003

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  6 in total

1.  Canal transportation and centering ratio after preparation in severely curved canals: analysis by micro-computed tomography and double-digital radiography.

Authors:  Ane Poly; Fouad AlMalki; Fernando Marques; Bekir Karabucak
Journal:  Clin Oral Investig       Date:  2019-03-05       Impact factor: 3.573

2.  Root canal curvature as a prognostic factor influencing the diagnostic accuracy of radiographic working length determination and postoperative canal axis modification: an in vitro comparative study.

Authors:  Bestoon Mohammed Faraj
Journal:  BMC Oral Health       Date:  2021-03-02       Impact factor: 2.757

3.  Canal transportation and centering ability of root canals prepared using rotary and reciprocating systems with and without PathFiles in cone-beam computed tomography-based three-dimensional molar prototypes.

Authors:  M Sruthi Sunildath; Josey Mathew; Liza George; R V Vineet; Priya Thomas; Dhanya John
Journal:  J Conserv Dent       Date:  2021-12-08

4.  In Vitro Transportation of Curved Canals Following Glide Path Preparation by Path File and Scout RaCe Rotary Systems versus Manual Instrumentation Using Cone-Beam Computed Tomography.

Authors:  Sareh Aflaki; Elham Boyerahmadi; Amir Talaei; Mohammad Raouf Safari; Mahdis Mohammadpour; Navid Mohammadi; Mamak Adel
Journal:  Front Dent       Date:  2020-11-15

Review 5.  The Effect of Glide Path Preparation on Root Canal Shaping Procedures and Outcomes.

Authors:  Mahdi Ajina; Georgios Billis; Bun San Chong
Journal:  Eur Endod J       Date:  2022-06

6.  Shaping Ability of XP Endo Shaper File in Curved Root Canal Models.

Authors:  Abdulmohsen Alfadley; Abdalrhman Alrajhi; Hamad Alissa; Faisal Alzeghaibi; Lubna Hamadah; Khalid Alfouzan; Ahmed Jamleh
Journal:  Int J Dent       Date:  2020-02-17
  6 in total