Literature DB >> 33642910

A New Method of Microcatheter Heat-Forming for Cerebral Aneurysmal Coiling Using Stereolithography Three-Dimensional Printed Hollow Vessel Models.

Sadao Nakajima1, Makoto Sakamoto1, Hiroki Yoshioka2, Tetsuji Uno1, Masamichi Kurosaki1.   

Abstract

BACKGROUND: To perform successful coil embolization of cerebral aneurysms, it is crucial to make an appropriately shaped microcatheter tip for an aneurysm and its parent artery. So far, we manually shaped a mandrel by referencing two-dimensional (2D) images of a rotation digital subtraction angiography (DSA) on a computer screen. However, this technique requires a lot of experience, and often involves trial and error. Recently, there have been increasing reports of manual mandrel shaping using a full-scale three-dimensional (3D) model of an aneurysm and its parent artery output by various types of 3D printer. We have further developed this method by producing a hollow model of an aneurysm and its parent artery with a stereolithography 3D printer and inserting a mandrel inside the model to fit and stabilize a microcatheter tip.
METHODS: Based on digital imaging and communications in medicine (DICOM) data obtained by rotational DSA, 3D images of an aneurysm and its parent artery were created and converted into standard triangulated language (STL) data. A hollow model was produced by extruding the STL data outward in the normal direction, and then a hole was made at the tip of the aneurysm using these STL data. We output these STL data to a stereolithography 3D printer. After cleaning and sterilizing the model, the mandrel was inserted in the direction of the parent artery through the hole made in the tip of the aneurysm and pushed in, creating the ideal mandrel shape. Twelve cases (14 aneurysms) were included in this study. A microcatheter tip was shaped by this method for patients who were scheduled to undergo coil embolization for an unruptured aneurysm.
RESULTS: In 13 of the 14 aneurysms, the microcatheter was easily guided into the aneurysms in one or two trials, the position of the microcatheter tip in the aneurysm was appropriate, and the stability during coil embolization was high.
CONCLUSION: Our method differs from the conventional one in that a hollow model made of resin is produced with a stereolithography 3D printer and that the mandrel is shaped by inserting it retrogradely into the hollow model. Using our new method, it will be possible to shape the tip of a microcatheter suitable for safe and stable coil embolization without relying on an operator's experience. ©2021 Tottori University Medical Press.

Entities:  

Keywords:  cerebral aneurysm; coil embolization; endovascular surgery; microcatheter shape; stereolithography 3D printer

Year:  2021        PMID: 33642910      PMCID: PMC7902171          DOI: 10.33160/yam.2021.02.001

Source DB:  PubMed          Journal:  Yonago Acta Med        ISSN: 0513-5710            Impact factor:   1.641


  6 in total

1.  Shapability, memory, and luminal changes in microcatheters after steam shaping: a comparison of 11 different microcatheters.

Authors:  Hiro Kiyosue; Yuzo Hori; Shunro Matsumoto; Mika Okahara; Syuichi Tanoue; Yoshiko Sagara; Hiromu Mori
Journal:  AJNR Am J Neuroradiol       Date:  2005 Nov-Dec       Impact factor: 3.825

Review 2.  Complications of endovascular treatment for intracranial aneurysms: Management and prevention.

Authors:  Yon Kwon Ihn; Shang Hun Shin; Seung Kug Baik; In Sup Choi
Journal:  Interv Neuroradiol       Date:  2018-02-21       Impact factor: 1.610

3.  Microcatheter Shaping for Intracranial Aneurysm Coiling Using the 3-Dimensional Printing Rapid Prototyping Technology: Preliminary Result in the First 10 Consecutive Cases.

Authors:  Katsunari Namba; Ayuho Higaki; Naoki Kaneko; Toshihiro Mashiko; Shigeru Nemoto; Eiju Watanabe
Journal:  World Neurosurg       Date:  2015-03-14       Impact factor: 2.104

4.  Tailor-made shaping of microcatheters using three-dimensional printed vessel models for endovascular coil embolization.

Authors:  Toshihiro Ishibashi; Hiroyuki Takao; Takashi Suzuki; Ichiro Yuki; Shogo Kaku; Issei Kan; Kengo Nishimura; Tomoaki Suzuki; Mitsuyosi Watanabe; Kostadin Karagiozov; Yuichi Murayama
Journal:  Comput Biol Med       Date:  2016-08-02       Impact factor: 4.589

5.  Technique for shaping microcatheter tips in coil embolization of paraclinoid aneurysms using full-scale volume rendering images of 3D rotational angiography.

Authors:  S Toyota; Y Fujimoto; F Iwamoto; A Wakayama; T Yoshimine
Journal:  Minim Invasive Neurosurg       Date:  2009-10-16

6.  Distal-tip shape-consistency testing of steam-shaped microcatheters suitable for cerebral aneurysm coil placement.

Authors:  Toshi Abe; Masaru Hirohata; Norimitsu Tanaka; Yusuke Uchiyama; Kiminori Fujimoto; Naoko Fujimura; Alexander M Norbash; Naofumi Hayabuchi
Journal:  AJNR Am J Neuroradiol       Date:  2004 Jun-Jul       Impact factor: 3.825

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.