Literature DB >> 33638579

The combined use of 2D scout and 3D axial CT images to accurately determine the catheter tips for high-dose-rate brachytherapy plans.

Kun Qing1,2, Ning J Yue1, Lara Hathout1, Chi Ma1, Meral Reyhan1, Jiahua Zhu1, Ke Nie1, Gilbert Monte1, Irina Vergalasova1.   

Abstract

PURPOSE: To develop a method combining CT scout images with axial images to improve the localization accuracy of catheter tips in high-dose-rate (HDR) brachytherapy treatments.
MATERIALS AND METHODS: CT scout images were utilized along with conventionally reconstructed axial images to aid the localization of catheter tips used during HDR treatment planning. A method was developed to take advantage of the finer image resolution of the scout images to more precisely identify the tip coordinates. The accuracies of this method were compared with the conventional method based on the axial CT images alone, for various slice thicknesses, in a computed tomography dose index (CTDI) head phantom. A clinical case which involved multiple interstitial catheters was also selected for the evaluation of this method. Locations of the catheter tips were reconstructed with the conventional CT-based method and this newly developed method, respectively. Location coordinates obtained via both methods were quantitatively compared.
RESULTS: Combination of the scout and axial CT images improved the accuracy of identification and reconstruction of catheter tips along the longitudinal direction (i.e., head-to-foot direction, more or less parallel to the catheter tracks), compared to relying on the axial CT images alone. The degree of improvement was dependent on CT slice thickness. For the clinical patient case, the coordinate differences of the reconstructed catheter tips were 2.6 mm ± 0.9 mm in the head-to-foot direction, 0.4 mm ± 0.2 mm in the left-to-right direction, and 0.6 mm ± 0.2 mm in the anterior-to-posterior direction, respectively.
CONCLUSION: Combining CT scout and axial images demonstrates the ability to provide a more accurate identification and reconstruction of the interstitial catheter tips for HDR brachytherapy treatment, especially in the longitudinal direction. The method developed in this work has the potential to be implemented clinically together with automatic segmentation in modern brachytherapy treatment planning systems, in order to improve the reconstruction accuracy of HDR catheters.
© 2021 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

Entities:  

Keywords:  CT; HDR; brachytherapy; catheter localization; scout

Mesh:

Year:  2021        PMID: 33638579      PMCID: PMC7984491          DOI: 10.1002/acm2.13184

Source DB:  PubMed          Journal:  J Appl Clin Med Phys        ISSN: 1526-9914            Impact factor:   2.102


  9 in total

1.  Combined use of transverse and scout computed tomography scans to localize radioactive seeds in an interstitial brachytherapy implant.

Authors:  N Yue; Z Chen; J E Bond; Y H Son; R Nath
Journal:  Med Phys       Date:  1999-04       Impact factor: 4.071

Review 2.  Principles of CT: radiation dose and image quality.

Authors:  Lee W Goldman
Journal:  J Nucl Med Technol       Date:  2007-11-15

Review 3.  Place of modern imaging in brachytherapy planning.

Authors:  T P Hellebust
Journal:  Cancer Radiother       Date:  2018-05-30       Impact factor: 1.018

4.  Practical considerations for prostate HDR brachytherapy.

Authors:  Eric D Slessinger
Journal:  Brachytherapy       Date:  2009-10-22       Impact factor: 2.362

5.  CT image artifacts from brachytherapy seed implants: a postprocessing 3D adaptive median filter.

Authors:  Parminder S Basran; Andrew Robertson; Derek Wells
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

6.  American Brachytherapy Society consensus guidelines for high-dose-rate prostate brachytherapy.

Authors:  Yoshiya Yamada; Leland Rogers; D Jeffrey Demanes; Gerard Morton; Bradley R Prestidge; Jean Pouliot; Gil'ad N Cohen; Marco Zaider; Mihai Ghilezan; I-Chow Hsu
Journal:  Brachytherapy       Date:  2012 Jan-Feb       Impact factor: 2.362

7.  American Brachytherapy Society consensus guidelines for locally advanced carcinoma of the cervix. Part II: high-dose-rate brachytherapy.

Authors:  Akila N Viswanathan; Sushil Beriwal; Jennifer F De Los Santos; D Jeffrey Demanes; David Gaffney; Jorgen Hansen; Ellen Jones; Christian Kirisits; Bruce Thomadsen; Beth Erickson
Journal:  Brachytherapy       Date:  2012 Jan-Feb       Impact factor: 2.362

8.  Effects of CT section thickness and reconstruction kernel on emphysema quantification relationship to the magnitude of the CT emphysema index.

Authors:  David S Gierada; Andrew J Bierhals; Cliff K Choong; Seth T Bartel; Jon H Ritter; Nitin A Das; Cheng Hong; Thomas K Pilgram; Kyongtae T Bae; Bruce R Whiting; Jason C Woods; James C Hogg; Barbara A Lutey; Richard J Battafarano; Joel D Cooper; Bryan F Meyers; G Alexander Patterson
Journal:  Acad Radiol       Date:  2010-02       Impact factor: 3.173

9.  CT Slice Thickness and Convolution Kernel Affect Performance of a Radiomic Model for Predicting EGFR Status in Non-Small Cell Lung Cancer: A Preliminary Study.

Authors:  Yajun Li; Lin Lu; Manjun Xiao; Laurent Dercle; Yue Huang; Zishu Zhang; Lawrence H Schwartz; Daiqiang Li; Binsheng Zhao
Journal:  Sci Rep       Date:  2018-12-17       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.