An evaluation and comparison of Reflolux II and Glucometer II, two new portable reflectance meters for capillary blood glucose determination.

G M Schier1, R G Moses, I E Gan, S C Blair.   

Abstract

The Reflolux II and the Glucometer II, two new battery-operated portable reflectance meters (PRMs) for blood glucose measurement have been evaluated for accuracy, precision and ease of operation. Both PRMs are pocket-size and simple to use. The calibration of the two instruments is fundamentally different, but in both cases the calibration data are provided with the reagent test strips and require minimal operator participation. The analysis time is 50 s for the Glucometer II and 120 s for the Reflolux II. The Reflolux II has a measuring range of 0.5-27.7 mmol/l, which is superior to the 2-22 mmol/l range of Glucometer II. Both PRMs had excellent correlation (r greater than 0.97) and minimal bias when compared by regression analysis to a laboratory method on capillary and whole blood samples. The precision of the Reflolux II was marginally better than the Glucometer II with coefficients of variation less than 6.57% for the Glucometer II and less than 5.21% for the Reflolux II. Neither the Reflolux II nor the Glucometer II offer significant advantages one over the other, both are adequate for their designed use, and both are distinct improvements over their predecessors.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3359917     DOI: 10.1016/s0168-8227(88)80015-9

Source DB:  PubMed          Journal:  Diabetes Res Clin Pract        ISSN: 0168-8227            Impact factor:   5.602


  13 in total

1.  Evaluation of two synthetic glucose probes for fluorescence-lifetime-based sensing.

Authors:  N DiCesare; J R Lakowicz
Journal:  Anal Biochem       Date:  2001-07-15       Impact factor: 3.365

2.  Nanogold-plasmon-resonance-based glucose sensing.

Authors:  Kadir Aslan; Joseph R Lakowicz; Chris D Geddes
Journal:  Anal Biochem       Date:  2004-07-01       Impact factor: 3.365

3.  Ophthalmic glucose sensing: a novel monosaccharide sensing disposable and colorless contact lens.

Authors:  Ramachandram Badugu; Joseph R Lakowicz; Chris D Geddes
Journal:  Analyst       Date:  2004-05-10       Impact factor: 4.616

Review 4.  Ophthalmic glucose monitoring using disposable contact lenses--a review.

Authors:  Ramachandram Badugu; Joseph R Lakowicz; Chris D Geddes
Journal:  J Fluoresc       Date:  2004-09       Impact factor: 2.217

Review 5.  A glucose-sensing contact lens: from bench top to patient.

Authors:  Ramachandram Badugu; Joseph R Lakowicz; Chris D Geddes
Journal:  Curr Opin Biotechnol       Date:  2005-02       Impact factor: 9.740

Review 6.  Saccharide sensing using gold and silver nanoparticles--a review.

Authors:  Kadir Aslan; Jian Zhang; Joseph R Lakowicz; Chris D Geddes
Journal:  J Fluoresc       Date:  2004-07       Impact factor: 2.217

7.  OPHTHALMIC GLUCOSE MONITORING USING DISPOSABLE CONTACT LENSES.

Authors:  Ramachandram Badugu; Joseph R Lakowicz; Chris D Geddes
Journal:  Rev Fluoresc       Date:  2005

8.  Tunable plasmonic glucose sensing based on the dissociation of Con A-aggregated dextran-coated gold colloids.

Authors:  Kadir Aslan; Joseph R Lakowicz; Chris D Geddes
Journal:  Anal Chim Acta       Date:  2004-06-15       Impact factor: 6.558

9.  Microneedle-based automated therapy for diabetes mellitus.

Authors:  Puneet Khanna; Joel A Strom; John I Malone; Shekhar Bhansali
Journal:  J Diabetes Sci Technol       Date:  2008-11

10.  A Glucose Sensing Contact Lens: A Non-Invasive Technique for Continuous Physiological Glucose Monitoring.

Authors:  Ramachandram Badugu; Joseph R Lakowicz; Chris D Geddes
Journal:  J Fluoresc       Date:  2003-09       Impact factor: 2.217

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.