Literature DB >> 31896834

Tunable plasmonic glucose sensing based on the dissociation of Con A-aggregated dextran-coated gold colloids.

Kadir Aslan1, Joseph R Lakowicz2, Chris D Geddes1,2.   

Abstract

We describe a new approach for glucose determination with tunable glucose dynamic sensing ranges, dependent on the properties of new nanosensors, which are comprised of Con A-aggregated dextran-coated gold colloids. Dextran-coated 10 or 20 nm gold colloids can be aggregated with Con A in a controlled fashion, the change in absorbance at an arbitrary wavelength used to monitor the extent of aggregation, which can be optimized for sensing. The presence of any glucose competitively binds with Con A, dissociating the dextran-coated colloids, affording for the reverse gold plasmon change and hence the determination of glucose concentrations. For one of our sensor systems, a 500K dextran-20 nm gold sensor, crosslinked with 8.70 µM Con A, a change in absorbance at 650 nm of 0.03 was observed, in response to as little as 3 mM glucose. In contrast, a 500K dextran-10 nm gold 18.7 µM Con A aggregate sensor, produced a 0.05 and 0.1 change in absorbance, respectively, by the addition of 50 and 100 mM glucose. We have found that the glucose sensing ranges can be somewhat tuned by altering the properties, and therefore the extent of aggregation of the gold aggregate sensors. Reducing the gold colloid size and dextran molecular weight typically reduces the glucose sensing range (lower [glucose]) but also reduces the long-term stability of the gold aggregate sensor. Similarly the concentration of Con A used to aggregate the system also has an effect on long term sensor stability and glucose response. In this paper, we present our findings, which offer unique opportunities and perspectives for building tunable plasmonic type glucose sensors.

Entities:  

Keywords:  Gold colloids; Plasmonic nanosensors; Tunable glucose sensor(s)

Year:  2004        PMID: 31896834      PMCID: PMC6939462          DOI: 10.1016/j.aca.2004.04.060

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  15 in total

1.  Metallic colloid wavelength-ratiometric scattering sensors.

Authors:  David Roll; Joanna Malicka; Ignacy Gryczynski; Zygmunt Gryczynski; Joseph R Lakowicz
Journal:  Anal Chem       Date:  2003-07-15       Impact factor: 6.986

2.  Noninvasive continuous monitoring of physiological glucose using a monosaccharide-sensing contact lens.

Authors:  Ramachandram Badugu; Joseph R Lakowicz; Chris D Geddes
Journal:  Anal Chem       Date:  2004-02-01       Impact factor: 6.986

3.  Noninvasive glucose monitoring in diabetic patients: a preliminary evaluation.

Authors:  M R Robinson; R P Eaton; D M Haaland; G W Koepp; E V Thomas; B R Stallard; P L Robinson
Journal:  Clin Chem       Date:  1992-09       Impact factor: 8.327

4.  A DNA-based method for rationally assembling nanoparticles into macroscopic materials.

Authors:  C A Mirkin; R L Letsinger; R C Mucic; J J Storhoff
Journal:  Nature       Date:  1996-08-15       Impact factor: 49.962

5.  An evaluation and comparison of Reflolux II and Glucometer II, two new portable reflectance meters for capillary blood glucose determination.

Authors:  G M Schier; R G Moses; I E Gan; S C Blair
Journal:  Diabetes Res Clin Pract       Date:  1988-02-19       Impact factor: 5.602

6.  Ocular glucose sensor.

Authors:  W F March; B Rabinovitch; R Adams; J R Wise; M Melton
Journal:  Trans Am Soc Artif Intern Organs       Date:  1982

7.  Recognition of potassium ion in water by 15-crown-5 functionalized gold nanoparticles.

Authors:  Sui-Yi Lin; Shi-Wei Liu; Chia-Mei Lin; Chun-hsien Chen
Journal:  Anal Chem       Date:  2002-01-15       Impact factor: 6.986

8.  A Glucose Sensing Contact Lens: A Non-Invasive Technique for Continuous Physiological Glucose Monitoring.

Authors:  Ramachandram Badugu; Joseph R Lakowicz; Chris D Geddes
Journal:  J Fluoresc       Date:  2003-09       Impact factor: 2.217

9.  Affinity sensor: a new technique for developing implantable sensors for glucose and other metabolites.

Authors:  J S Schultz; S Mansouri; I J Goldstein
Journal:  Diabetes Care       Date:  1982 May-Jun       Impact factor: 19.112

10.  Fiber-optic biosensors based on fluorescence energy transfer.

Authors:  D Meadows; J S Schultz
Journal:  Talanta       Date:  1988-02       Impact factor: 6.057

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.