Pre- and postoperative refraction after cataract extraction with implantation of standard power IOL.

T Olsen1.   

Abstract

The pre- and postoperative refraction results are reported in 99 patients receiving an anterior chamber lens of standard 19.0 D power after intracapsular cataract extraction. The mean refraction after the operation was -0.76 D, SD 2.13. Apart from eight patients with suspected lenticular myopia, 5% of the patients ended up with a refraction that differed more than +/- 5D from the preoperative value. This variation was due to variation in the power of the biological lens removed at surgery, the mean value of which was 22.8 D, SD 3.3. As a measure of the aniseikonia induced at surgery, the ocular magnification was calculated to increase 2.7%, SD 4.2%, as compared with the preoperative value. The variation should be considered in the discussion of whether a preoperative biometry and calculation of appropriate IOL power are recommended or not.

Entities:  

Mesh:

Year:  1988        PMID: 3355811      PMCID: PMC1041415          DOI: 10.1136/bjo.72.3.231

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  17 in total

Review 1.  ARTIPHAKIA AND ANISEIKONIA.

Authors:  R C TROUTMAN
Journal:  Am J Ophthalmol       Date:  1963-10       Impact factor: 5.258

2.  Pitfalls in the determination of intraocular lens power without ultrasound.

Authors:  R D Binkhorst
Journal:  Ophthalmic Surg       Date:  1976

Review 3.  Standardized echography: basic principles, clinical applications, and results.

Authors:  K C Ossoinig
Journal:  Int Ophthalmol Clin       Date:  1979

4.  Clinical aspects of unilateral aphakia.

Authors:  J Nolan; A Hawkswell
Journal:  Trans Ophthalmol Soc U K       Date:  1974-07

5.  Calculation of the power of an iris clip lens for distant vision.

Authors:  M C Colenbrander
Journal:  Br J Ophthalmol       Date:  1973-10       Impact factor: 4.638

6.  Theoretical approach to intraocular lens calculation using Gaussian optics.

Authors:  T Olsen
Journal:  J Cataract Refract Surg       Date:  1987-03       Impact factor: 3.351

7.  Determination of intraocular lens power: a comparison with and without ultrasound.

Authors:  M C Kraff; D R Sanders; H L Lieberman
Journal:  Ophthalmic Surg       Date:  1978-02

8.  A new intraocular lens calculation formula.

Authors:  J Retzlaff
Journal:  J Am Intraocul Implant Soc       Date:  1980-04

9.  Clinical prediction versus ultrasound measurement of IOL power.

Authors:  C E Clevenger
Journal:  J Am Intraocul Implant Soc       Date:  1978-10

10.  Results in 208 iris-clip pseudophakos implantations.

Authors:  C D Binkhorst; P A Leonard
Journal:  Am J Ophthalmol       Date:  1967-11       Impact factor: 5.258

View more
  2 in total

Review 1.  Optimising biometry for best outcomes in cataract surgery.

Authors:  R Sheard
Journal:  Eye (Lond)       Date:  2013-12-06       Impact factor: 3.775

Review 2.  Reviewing the visual benefits of femtosecond laser-assisted cataract surgery: Can we improve our outcomes?

Authors:  Michael Lawless; Lewis Levitz; Chris Hodge
Journal:  Indian J Ophthalmol       Date:  2017-12       Impact factor: 1.848

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.