Literature DB >> 3355721

Feasibility and variability of six methods for the echocardiographic and Doppler determination of cardiac output.

G L Nicolosi1, E Pungercic, E Cervesato, D Pavan, L Modena, E Moro, V Dall'Aglio, D Zanuttini.   

Abstract

The feasibility and the intrinsic variability of six different methods of echocardiographic and Doppler flow determination of cardiac output were analysed in 34 healthy volunteers. Four were excluded because of poor quality echocardiograms. The mean (range) age of the remaining 30 (12 women, 18 men) was 21 years (13-36 years). Cardiac output was calculated by six methods as a product of echocardiographically determined cross sectional area of the aorta (apical and suprasternal views), pulmonary trunk, tricuspid annulus, and mitral annulus (circular and corrected for diastolic variations), and the flow velocity integral measured by Doppler. Cardiac output ranged from 2.79 to 6.56 1/min (4.45 (1.29) 1/min) (mean (SD)). The feasibility of the methods ranged from 87% (26 patients) for the aorta from the suprasternal notch to 100% (30 patients) for the mitral orifice corrected for diastolic variations and for the tricuspid valve. The corresponding results for all 34 individuals were 76% and 88% respectively. Three way analysis of variance was performed in the 23 healthy volunteers in whom all six methods were feasible. Interobserver and intraobserver interpretative variabilities were 6.8% and 5.9% respectively. The intrinsic variability of each single measurement of cardiac output, independently of the observer and the method used, was 25%. Provided the image was suitable for analysis echocardiographic and Doppler flow determination of cardiac output was feasible in most healthy volunteers. But there was significant intrinsic variability for each of different methods. A single value of cardiac output in an individual should be interpreted with caution.

Entities:  

Mesh:

Year:  1988        PMID: 3355721      PMCID: PMC1216463          DOI: 10.1136/hrt.59.3.299

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  23 in total

1.  Determination of cardiac output by Doppler echocardiography.

Authors:  H Ihlen; J P Amlie; J Dale; K Forfang; S Nitter-Hauge; J E Otterstad; S Simonsen; E Myhre
Journal:  Br Heart J       Date:  1984-01

2.  A two-dimensional Doppler echocardiographic method for calculation of pulmonary and systemic blood flow in a canine model with a variable-sized left-to-right extracardiac shunt.

Authors:  E J Meijboom; L M Valdes-Cruz; S Horowitz; D J Sahn; D F Larson; K A Young; C Oliveira Lima; S J Goldberg; H D Allen
Journal:  Circulation       Date:  1983-08       Impact factor: 29.690

3.  Sources of variability in echocardiographic measurements.

Authors:  J M Felner; B A Blumenstein; R C Schlant; A D Carter; B N Alimurung; M J Johnson; S W Sherman; M W Klicpera; M H Kutner; L W Drucker
Journal:  Am J Cardiol       Date:  1980-05       Impact factor: 2.778

4.  Monitoring of changes in cardiac output by transcutaneous aortovelography, a non-invasive Doppler technique: comparison with thermodilution.

Authors:  A Distante; E Moscarelli; D Rovai; A L'Abbate
Journal:  J Nucl Med Allied Sci       Date:  1980 Jul-Dec

5.  Noninvasive Doppler determination of cardiac output in man. Clinical validation.

Authors:  L L Huntsman; D K Stewart; S R Barnes; S B Franklin; J S Colocousis; E A Hessel
Journal:  Circulation       Date:  1983-03       Impact factor: 29.690

6.  The mitral valve orifice method for noninvasive two-dimensional echo Doppler determinations of cardiac output.

Authors:  D C Fisher; D J Sahn; M J Friedman; D Larson; L M Valdes-Cruz; S Horowitz; S J Goldberg; H D Allen
Journal:  Circulation       Date:  1983-04       Impact factor: 29.690

7.  Clinical utility of two-dimensional doppler echocardiographic techniques for estimating pulmonary to systemic blood flow ratios in children with left to right shunting atrial septal defect, ventricular septal defect or patent ductus arteriosus.

Authors:  J Vargas Barron; D J Sahn; L M Valdes-Cruz; C O Lima; S J Goldberg; E Grenadier; H D Allen
Journal:  J Am Coll Cardiol       Date:  1984-01       Impact factor: 24.094

8.  Noninvasive evaluation of the ratio of pulmonary to systemic flow in atrial septal defect by duplex Doppler echocardiography.

Authors:  A Kitabatake; M Inoue; M Asao; H Ito; T Masuyama; J Tanouchi; T Morita; M Hori; H Yoshima; K Ohnishi
Journal:  Circulation       Date:  1984-01       Impact factor: 29.690

9.  The effect of variations of pulsed Doppler sampling site on calculation of cardiac output: an experimental study in open-chest dogs.

Authors:  D C Fisher; D J Sahn; M J Friedman; D Larson; L M Valdes-Cruz; S Horowitz; S J Goldberg; H D Allen
Journal:  Circulation       Date:  1983-02       Impact factor: 29.690

10.  A pulsed Doppler echocardiographic method for calculating pulmonary and systemic blood flow in atrial level shunts: validation studies in animals and initial human experience.

Authors:  L M Valdes-Cruz; S Horowitz; E Mesel; D J Sahn; D C Fisher; D Larson
Journal:  Circulation       Date:  1984-01       Impact factor: 29.690

View more
  8 in total

Review 1.  Doppler echocardiography for the estimation of cardiac output with exercise.

Authors:  Thomas Rowland; Philippe Obert
Journal:  Sports Med       Date:  2002       Impact factor: 11.136

2.  Determination of prestenotic flow volume using an automated method based on colour Doppler imaging for evaluating orifice area by the continuity equation: validation in a pulsatile flow model.

Authors:  K Dennig; H J Nesser; D Hall; H U Haase; A Schömig
Journal:  Heart       Date:  1998-04       Impact factor: 5.994

3.  Cross sectional early mitral flow velocity profiles from colour Doppler.

Authors:  S O Samstad; H G Torp; D T Linker; O Rossvoll; T Skjaerpe; E Johansen; K Kristoffersen; B A Angelsen; L Hatle
Journal:  Br Heart J       Date:  1989-09

4.  Non-invasive determination of cardiac output by Doppler echocardiography and electrical bioimpedance.

Authors:  D B Northridge; I N Findlay; J Wilson; E Henderson; H J Dargie
Journal:  Br Heart J       Date:  1990-02

Review 5.  Reliability and validity of measures of cardiac output during incremental to maximal aerobic exercise. Part II: Novel techniques and new advances.

Authors:  D E Warburton; M J Haykowsky; H A Quinney; D P Humen; K K Teo
Journal:  Sports Med       Date:  1999-04       Impact factor: 11.136

6.  Reference values of aortic flow velocity integral in 1193 healthy infants, children, and adolescents to quickly estimate cardiac stroke volume.

Authors:  Christiane Pees; Eva Glagau; Jakob Hauser; Ina Michel-Behnke
Journal:  Pediatr Cardiol       Date:  2013-01-24       Impact factor: 1.655

7.  Hemodynamic effects of sodium bicarbonate in critically ill neonates.

Authors:  S Fanconi; R Burger; D Ghelfi; J Uehlinger; U Arbenz
Journal:  Intensive Care Med       Date:  1993       Impact factor: 17.440

8.  Correlation of carotid blood flow and corrected carotid flow time with invasive cardiac output measurements.

Authors:  Irene W Y Ma; Joshua D Caplin; Aftab Azad; Christina Wilson; Michael A Fifer; Aranya Bagchi; Andrew S Liteplo; Vicki E Noble
Journal:  Crit Ultrasound J       Date:  2017-04-20
  8 in total