Literature DB >> 33547354

Photoneutron spectrometry by novel multi-directional spherical neutron spectrometry system.

Mehdi Sohrabi1, Amir Hakimi2.   

Abstract

Neutron spectrometry in science and technology applications in general and accurate exotic photoneutron (PN) dosimetry of cancer patients undergoing high-dose high-energy X-rays therapy in medical accelerators in particular is of vital need. In this study, a novel passive multi-directional multi-detector neutron spectrometry system was developed and home-made using 6 polycarbonate/10B detectors on 6 sides of polyethylene (PE) cubes used bare and also embedded at center of PE spheres of 8 different diameters. The system provided well-resolved unfolded directional PN spectra showing thermal and fast PN peaks of 6 sides and mean spectrum in 5 field sizes at isocenter and other locations in 18 MV Siemens ONCOR medical linear accelerator bunker. The neutron spectrometry system developed has unique characteristics such as being simple, efficient, low cost, practical, and insensitive to low-LET radiation with well-resolved directional and mean spectra easily applicable in medicine, health, environment, science and technology in developing and developed laboratories.

Entities:  

Year:  2021        PMID: 33547354      PMCID: PMC7864933          DOI: 10.1038/s41598-021-81529-5

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.379


  28 in total

1.  Neutron spectra unfolding in Bonner spheres spectrometry using neural networks.

Authors:  M R Kardan; S Setayeshi; R Koohi-Fayegh; M Ghiassi-Nejad
Journal:  Radiat Prot Dosimetry       Date:  2003       Impact factor: 0.972

2.  Measuring neutron spectra in radiotherapy using the nested neutron spectrometer.

Authors:  Robert Maglieri; Angel Licea; Michael Evans; Jan Seuntjens; John Kildea
Journal:  Med Phys       Date:  2015-11       Impact factor: 4.071

3.  A SINGLE-EXPOSURE, MULTIDETECTOR NEUTRON SPECTROMETER FOR WORKPLACE MONITORING.

Authors:  R Bedogni; D Bortot; B Buonomo; A Esposito; J M Gómez-Ros; M V Introini; G Mazzitelli; M Moraleda; A Pola; A M Romero
Journal:  Radiat Prot Dosimetry       Date:  2015-08-13       Impact factor: 0.972

4.  Calculation of effective dose from measurements of secondary neutron spectra and scattered photon dose from dynamic MLC IMRT for 6 MV, 15 MV, and 18 MV beam energies.

Authors:  Rebecca M Howell; Nolan E Hertel; Zhonglu Wang; Jesson Hutchinson; Gary D Fullerton
Journal:  Med Phys       Date:  2006-02       Impact factor: 4.071

5.  Photoneutron depth dose equivalent distributions in high-energy X-ray medical accelerators by a novel position-sensitive dosimeter.

Authors:  Amir Hakimi; Mehdi Sohrabi
Journal:  Phys Med       Date:  2017-03-23       Impact factor: 2.685

6.  Novel 6MV X-ray photoneutron detection and dosimetry of medical accelerators.

Authors:  Mehdi Sohrabi; Amir Hakimi
Journal:  Phys Med       Date:  2017-03-30       Impact factor: 2.685

7.  Estimation of photoneutron yield in linear accelerator with different collimation systems by Geant4 and MCNPX simulation codes.

Authors:  Yoon Sang Kim; Zeinab Khazaei; Junho Ko; Hossein Afarideh; Mitra Ghergherehchi
Journal:  Phys Med Biol       Date:  2016-03-15       Impact factor: 3.609

8.  A novel position-sensitive mega-size dosimeter for photoneutrons in high-energy X-ray medical accelerators.

Authors:  Mehdi Sohrabi; Amir Hakimi; Seyed Rabi Mahdavi
Journal:  Phys Med       Date:  2016-05-09       Impact factor: 2.685

9.  BACKGROUND TRACK DENSITY REDUCTION OF 50-HZ-HV ECE-PROCESSED THICK POLYCARBONATE DETECTORS TO IMPROVE LOWER DETECTION LIMIT.

Authors:  M Sohrabi; A Hakimi; Z Soltani
Journal:  Radiat Prot Dosimetry       Date:  2015-11-12       Impact factor: 0.972

10.  NOVEL 'PHOTONEUTRON VOLUME DOSE EQUIVALENT' HYPOTHESIS AND METHODOLOGY FOR SECOND PRIMARY CANCER RISK ESTIMATION IN HIGH-ENERGY X-RAY MEDICAL ACCELERATORS.

Authors:  Mehdi Sohrabi; Amir Hakimi
Journal:  Radiat Prot Dosimetry       Date:  2020-07-02       Impact factor: 0.972

View more
  2 in total

1.  Breakthrough whole body energy-specific and tissue-specific photoneutron dosimetry by novel miniature neutron dosimeter/spectrometer.

Authors:  Mehdi Sohrabi; Morteza Ebrahimzadeh Torkamani
Journal:  Sci Rep       Date:  2021-10-15       Impact factor: 4.379

2.  Semi-experimental assessment of neutron equivalent dose and secondary cancer risk for off-field organs in glioma patients undergoing 18-MV radiotherapy.

Authors:  Soheil Elmtalab; Iraj Abedi; Zahra Alirezaei; Mohammad Hossein Choopan Dastjerdi; Ghazale Geraily; Amir Hossein Karimi
Journal:  PLoS One       Date:  2022-07-29       Impact factor: 3.752

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.