Literature DB >> 19939692

An alternative method to match planned and achieved positions of implants, after virtual planning using cone-beam CT data and surgical guide templates--a method reducing patient radiation exposure (part I).

Hans-Joachim Nickenig1, Stephan Eitner.   

Abstract

OBJECTIVES: The present study describes a new method of evaluating the precision of surgically placed dental implants compared after virtual planning of implant positions using cone-beam computed tomography (CT) data and surgical guide templates. This method reduces radiation exposure for patients participating in scientific studies.
MATERIALS AND METHODS: Twenty-three implants in 10 patients with a unilateral free-end gap in the mandible (Kennedy Class II) were evaluated. After three-dimensional planning of implant position, the implant bed was prepared with a surgical guide template and transmucosal drilling. Preoperative cone-beam CT images were matched with postoperative images of the master cast with implant replicas. Deviations between planned and achieved positions were measured in position and axis.
RESULTS: On average, the match between planned and placed implant axis was within 4.2 degrees (range, 0.0-10.0). The mean difference in distance at the implant shoulder was 0.9 mm (range, 0.0-4.5). The mean difference in distance at the implant apex was 0.6mm (range, 0.0-2.7) in the lateral/medial direction and 0.9 mm (range, 0.0-3.4) in the anterior/posterior direction.
CONCLUSIONS: This alternative matching method provides reliable postoperative evaluation of differences in position and axis of planned and placed implants while reducing patient radiation exposure. Copyright 2009 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 19939692     DOI: 10.1016/j.jcms.2009.10.025

Source DB:  PubMed          Journal:  J Craniomaxillofac Surg        ISSN: 1010-5182            Impact factor:   2.078


  4 in total

1.  A method for segmentation of dental implants and crestal bone.

Authors:  Pedro Cunha; Miguel A Guevara; Ana Messias; Salomão Rocha; Rita Reis; Pedro M G Nicolau
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-12-02       Impact factor: 2.924

2.  Validation of an Intra-Oral Scan Method Versus Cone Beam Computed Tomography Superimposition to Assess the Accuracy between Planned and Achieved Dental Implants: A Randomized In Vitro Study.

Authors:  Alessio Franchina; Luigi V Stefanelli; Fabio Maltese; George A Mandelaris; Alessandro Vantaggiato; Michele Pagliarulo; Nicola Pranno; Edoardo Brauner; Francesca De Angelis; Stefano Di Carlo
Journal:  Int J Environ Res Public Health       Date:  2020-12-14       Impact factor: 3.390

3.  Accuracy of implant surgery with surgical guide by inexperienced clinicians: an in vitro study.

Authors:  Takeshi Toyoshima; Hideaki Tanaka; Masanori Sasaki; Eiji Ichimaru; Yasushi Naito; Yasuyuki Matsushita; Kiyoshi Koyano; Seiji Nakamura
Journal:  Clin Exp Dent Res       Date:  2015-07-14

4.  Dental implant location via surface scanner: a pilot study.

Authors:  Miao Zhou; Hui Zhou; Shu-Yi Li; Yuan-Ming Geng
Journal:  BMC Oral Health       Date:  2020-11-04       Impact factor: 2.757

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.