Hans-Joachim Nickenig1, Stephan Eitner. 1. Department of Prosthodontics, University Hospital Erlangen, Erlangen, Germany. Dr.A.Nickenig@t-online.de
Abstract
OBJECTIVES: The present study describes a new method of evaluating the precision of surgically placed dental implants compared after virtual planning of implant positions using cone-beam computed tomography (CT) data and surgical guide templates. This method reduces radiation exposure for patients participating in scientific studies. MATERIALS AND METHODS: Twenty-three implants in 10 patients with a unilateral free-end gap in the mandible (Kennedy Class II) were evaluated. After three-dimensional planning of implant position, the implant bed was prepared with a surgical guide template and transmucosal drilling. Preoperative cone-beam CT images were matched with postoperative images of the master cast with implant replicas. Deviations between planned and achieved positions were measured in position and axis. RESULTS: On average, the match between planned and placed implant axis was within 4.2 degrees (range, 0.0-10.0). The mean difference in distance at the implant shoulder was 0.9 mm (range, 0.0-4.5). The mean difference in distance at the implant apex was 0.6mm (range, 0.0-2.7) in the lateral/medial direction and 0.9 mm (range, 0.0-3.4) in the anterior/posterior direction. CONCLUSIONS: This alternative matching method provides reliable postoperative evaluation of differences in position and axis of planned and placed implants while reducing patient radiation exposure. Copyright 2009 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
OBJECTIVES: The present study describes a new method of evaluating the precision of surgically placed dental implants compared after virtual planning of implant positions using cone-beam computed tomography (CT) data and surgical guide templates. This method reduces radiation exposure for patients participating in scientific studies. MATERIALS AND METHODS: Twenty-three implants in 10 patients with a unilateral free-end gap in the mandible (Kennedy Class II) were evaluated. After three-dimensional planning of implant position, the implant bed was prepared with a surgical guide template and transmucosal drilling. Preoperative cone-beam CT images were matched with postoperative images of the master cast with implant replicas. Deviations between planned and achieved positions were measured in position and axis. RESULTS: On average, the match between planned and placed implant axis was within 4.2 degrees (range, 0.0-10.0). The mean difference in distance at the implant shoulder was 0.9 mm (range, 0.0-4.5). The mean difference in distance at the implant apex was 0.6mm (range, 0.0-2.7) in the lateral/medial direction and 0.9 mm (range, 0.0-3.4) in the anterior/posterior direction. CONCLUSIONS: This alternative matching method provides reliable postoperative evaluation of differences in position and axis of planned and placed implants while reducing patient radiation exposure. Copyright 2009 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Authors: Pedro Cunha; Miguel A Guevara; Ana Messias; Salomão Rocha; Rita Reis; Pedro M G Nicolau Journal: Int J Comput Assist Radiol Surg Date: 2012-12-02 Impact factor: 2.924
Authors: Alessio Franchina; Luigi V Stefanelli; Fabio Maltese; George A Mandelaris; Alessandro Vantaggiato; Michele Pagliarulo; Nicola Pranno; Edoardo Brauner; Francesca De Angelis; Stefano Di Carlo Journal: Int J Environ Res Public Health Date: 2020-12-14 Impact factor: 3.390