Comparative analysis of stress distribution in one-piece and two-piece implants with narrow and extra-narrow diameters: A finite element study.

Fabricia Teixeira Barbosa1, Luiz Carlos Silveira Zanatta1, Edélcio de Souza Rendohl2, Sergio Alexandre Gehrke3,4.   

Abstract

OBJECTIVES: The aim of this in vitro study was to evaluate the stress distribution on three implant models with narrow and extra-narrow diameters using the finite element method (FEA).
MATERIALS AND METHODS: Dental implants of extra-narrow diameter of 2.5 mm for a one-piece implant (group G1), a narrow diameter of 3.0 mm for a one-piece implant (group G2) and a narrow diameter of 3.5 mm for a two-piece implant with a Morse taper connection (group G3). A three-dimensional model was designed with cortical and cancellous bone, a crown and an implant/abutment set of each group. Axial and angled (30°) loads of 150 N was applied. The equivalent von Mises stress was used for the implants and peri-implant bone plus the Mohr-Coulomb analysis to confirm the data of the peri-implant bone.
RESULTS: In the axial load, the maximum stress value of the cortical bone for the group G1 was 22.35% higher than that the group G2 and 321.23% than the group G3. Whereas in angled load, the groups G1 and G2 showing a similar value (# 3.5%) and a highest difference for the group G3 (391.8%). In the implant structure, the group G1 showed a value of 2188MPa, 93.6% higher than the limit.
CONCLUSIONS: The results of this study show that the extra-narrow one-piece implant should be used with great caution, especially in areas of non-axial loads, whereas the one- and two-piece narrow-diameter implants show adequate behavior in both directions of the applied load.

Entities:  

Mesh:

Year:  2021        PMID: 33539392      PMCID: PMC7861395          DOI: 10.1371/journal.pone.0245800

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.240


  42 in total

1.  Optimal design of thread height and width on an immediately loaded cylinder implant: a finite element analysis.

Authors:  Jianhua Ao; Tao Li; Yanpu Liu; Yin Ding; Guofeng Wu; Kaijin Hu; Liang Kong
Journal:  Comput Biol Med       Date:  2010-08       Impact factor: 4.589

2.  Comparison of strain generated in bone by "platform-switched" and "non-platform-switched" implants with straight and angulated abutments under vertical and angulated load: a finite element analysis study.

Authors:  Susan Paul; T V Padmanabhan; Shailee Swarup
Journal:  Indian J Dent Res       Date:  2013 Jan-Feb

3.  Finite element analysis of stress extent at peri-implant bone surrounding external hexagon or Morse taper implants.

Authors:  J P Macedo; J Pereira; J Faria; C A Pereira; J L Alves; B Henriques; J C M Souza; J López-López
Journal:  J Mech Behav Biomed Mater       Date:  2017-03-21

4.  Fatigue Failure of Narrow Implants with Different Implant-Abutment Connection Designs.

Authors:  Dimorvan Bordin; Lukasz Witek; Vinícius P Fardin; Estevam A Bonfante; Paulo G Coelho
Journal:  J Prosthodont       Date:  2016-11-18       Impact factor: 2.752

5.  Narrow-diameter implants: A systematic review and meta-analysis.

Authors:  Eik Schiegnitz; Bilal Al-Nawas
Journal:  Clin Oral Implants Res       Date:  2018-10       Impact factor: 5.977

6.  Three-Dimensional Finite Element Analysis of Stress Distribution in Zirconia and Titanium Dental Implants.

Authors:  Camilo Andres Villabona Lopez; Marco Antônio Amorin Vasco; Edwin Ruales; Karin Apaza Bedoya; Cesar Magalhaes Benfatti; Osvaldo Luis Bezzon; Tatiana Miranda Deliberador
Journal:  J Oral Implantol       Date:  2018-05-15       Impact factor: 1.779

7.  Fracture strength and probability of survival of narrow and extra-narrow dental implants after fatigue testing: In vitro and in silico analysis.

Authors:  Dimorvan Bordin; Edmara T P Bergamo; Vinicius P Fardin; Paulo G Coelho; Estevam A Bonfante
Journal:  J Mech Behav Biomed Mater       Date:  2017-03-27

8.  Long-Term Retrospective Evaluation of Success of Narrow-Diameter Implants in Esthetic Areas: A Consecutive Case Series with 3 to 14 Years Follow-up.

Authors:  Stuart J Froum; Ye Shi; Francois Fisselier; Sang-Choon Cho
Journal:  Int J Periodontics Restorative Dent       Date:  2017 Sep/Oct       Impact factor: 1.840

9.  Biomechanical finite element analysis of a single implant threaded in anterior and posterior regions of maxilla bone.

Authors:  Laith A Sabri; Falah A Hussein; Abdulsalam R Al-Zahawi; Besaran Y Abdulrahman; Kareem N Salloomi
Journal:  Indian J Dent Res       Date:  2020 Mar-Apr

10.  A New Model to Study Fatigue in Dental Implants Based on Probabilistic Finite Elements and Cumulative Damage Model.

Authors:  María Prados-Privado; José Antonio Bea; Rosa Rojo; Sérgio A Gehrke; José Luis Calvo-Guirado; Juan Carlos Prados-Frutos
Journal:  Appl Bionics Biomech       Date:  2017-07-05       Impact factor: 1.781

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.