Literature DB >> 20599193

Optimal design of thread height and width on an immediately loaded cylinder implant: a finite element analysis.

Jianhua Ao1, Tao Li, Yanpu Liu, Yin Ding, Guofeng Wu, Kaijin Hu, Liang Kong.   

Abstract

In this study, we used a finite element method to evaluate the maximum Von Mises stresses in jaw bones of immediately loaded implant with different thread heights and widths, and the maximum displacements in implant-abutment complex. The implant thread height ranged from 0.20 to 0.60 mm, and the thread width ranged from 0.10 to 0.40 mm. Compared to those in standard designed implants, the maximum Von Mises stresses in cortical and cancellous bones with axially loaded implants decreased by 18.85% and 47.46%, respectively, and by 16.38% and 63.46%, respectively in buccolingually loaded implants. The maximum displacement of implant-abutment complex loaded axially and buccolingually decreased by 13.78% and 6.97%, respectively. These results indicated that thread height played more important roles in affecting bone stresses and implant-abutment complex stability than thread width. Immediately loaded cylinder implants with thread height exceeding 0.44 mm and width ranging from 0.19 to 0.23 mm caused the lowest stresses to the type B/2 bone. Copyright 2009 Elsevier Ltd. All rights reserved.

Mesh:

Substances:

Year:  2010        PMID: 20599193     DOI: 10.1016/j.compbiomed.2009.10.007

Source DB:  PubMed          Journal:  Comput Biol Med        ISSN: 0010-4825            Impact factor:   4.589


  8 in total

1.  Macroscopic and microscopic evaluation of a new implant design supporting immediately loaded full arch rehabilitation.

Authors:  Stefano Tetè; Vincenzo Zizzari; Alessandro De Carlo; Bruna Sinjari; Enrico Gherlone
Journal:  Ann Stomatol (Roma)       Date:  2012-08-09

2.  The influence of thread geometry on implant osseointegration under immediate loading: a literature review.

Authors:  Hyo-Sook Ryu; Cheol Namgung; Jong-Ho Lee; Young-Jun Lim
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

3.  The effect of the thread depth on the mechanical properties of the dental implant.

Authors:  Sun-Young Lee; Sung-Jun Kim; Hyun-Wook An; Hyun-Seung Kim; Dong-Guk Ha; Kyung-Ho Ryo; Kwang-Bum Park
Journal:  J Adv Prosthodont       Date:  2015-04-23       Impact factor: 1.904

4.  Finite Element Analysis of Bone Stress around Micro-Implants of Different Diameters and Lengths with Application of a Single or Composite Torque Force.

Authors:  Ying-juan Lu; Shao-hai Chang; Jian-tao Ye; Yu-shan Ye; Yan-song Yu
Journal:  PLoS One       Date:  2015-12-14       Impact factor: 3.240

5.  Assessing the Effect of Dental Implants Thread Design on Distribution of Stress in Impact Loadings Using Three Dimensional Finite Element Method.

Authors:  Zarei I; Khajehpour S; Sabouri A; Haghnegahdar Az; Jafari K
Journal:  J Dent Biomater       Date:  2016-06

6.  Relevant Design Aspects to Improve the Stability of Titanium Dental Implants.

Authors:  M Herrero-Climent; P López-Jarana; B F Lemos; F J Gil; C Falcão; J V Ríos-Santos; B Ríos-Carrasco
Journal:  Materials (Basel)       Date:  2020-04-18       Impact factor: 3.623

7.  Comparative analysis of stress distribution in one-piece and two-piece implants with narrow and extra-narrow diameters: A finite element study.

Authors:  Fabricia Teixeira Barbosa; Luiz Carlos Silveira Zanatta; Edélcio de Souza Rendohl; Sergio Alexandre Gehrke
Journal:  PLoS One       Date:  2021-02-04       Impact factor: 3.240

8.  Influence of Implant Thread Morphology on Primary Stability: A Prospective Clinical Study.

Authors:  Maria Menini; Francesco Bagnasco; Ivan Calimodio; Nicolò Di Tullio; Francesca Delucchi; Domenico Baldi; Francesco Pera
Journal:  Biomed Res Int       Date:  2020-08-05       Impact factor: 3.411

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.