Initial Experience With a Bioresorbable Polymer Anchor.

Robert R Burnham1, Jayanth Kumar2, Michael Pinzur1, Adam Schiff1.   

Abstract

Background Anchors are frequently used in reconstructive orthopedic surgery to achieve fixation of soft tissue to bone. Anchors vary with respect to material composition, configuration, and methods of fixation at the site of attachment. The fixation component of anchoring devices has generally evolved from metal-fabricated implants to various types of bioresorbable anchors. The SonicAnchorTM (Stryker, Kalamazoo, MI USA) polymer implant provides a unique form of anchor fixation using SonicFusionTM technology to achieve interdigitation within cancellous bone while being radiolucent and providing a small footprint. Methods During a four-year period, 116 patients underwent a reconstructive orthopedic foot and ankle surgical procedure with the use of at least one bioresorbable polymer anchor (SonicAnchor implant). There were 59 males and 57 females, with an average age of 42 years (range: 12-83 years). Results A total of 233 bioresorbable anchor (SonicAnchor) implants were used in 116 patients. Of the 116 patients, 108 (93.1%) achieved successful clinical healing of their surgery at their most recent follow-up. The average follow-up duration was 309 days (range: 14-1,429 days). Eight (6.9%) patients were lost to follow-up prior to clinical healing. Two (1.7%) patients underwent reoperation. Also, 65 (56%) patients had at least six months of follow-up and 36 (31%) had at least one year of follow-up. Conclusions This preliminary clinical trial of patients undergoing soft tissue repair or reconstruction with a bioresorbable polymer appears to perform comparably to other commercially available devices. The lack of adverse events, mechanical failures, or infections further supports the safety of this device.
Copyright © 2020, Burnham et al.

Entities:  

Keywords:  bioresorbable implant; deltoid ligament repair; lateral ankle ligament instability; polymer implant; soft tissue fixation; sonicanchor

Year:  2020        PMID: 33527051      PMCID: PMC7842253          DOI: 10.7759/cureus.12370

Source DB:  PubMed          Journal:  Cureus        ISSN: 2168-8184


  21 in total

Review 1.  Fixation of Soft Tissue to Bone: Techniques and Fundamentals.

Authors:  Brian J Cole; Eli T Sayegh; Adam B Yanke; Peter N Chalmers; Rachel M Frank
Journal:  J Am Acad Orthop Surg       Date:  2016-02       Impact factor: 3.020

2.  Cyclic testing of pullout sutures and micro-mitek suture anchors in flexor digitorum profundus tendon distal fixation.

Authors:  K Latendresse; E Dona; P J Scougall; F B Schreuder; Emma Puchert; William R Walsh
Journal:  J Hand Surg Am       Date:  2005-05       Impact factor: 2.230

3.  Comparison between different femoral fixation devices for ACL reconstruction with doubled hamstring tendon graft: a biomechanical analysis.

Authors:  Giuseppe Milano; Pier Damiano Mulas; Fabio Ziranu; Stefano Piras; Andrea Manunta; Carlo Fabbriciani
Journal:  Arthroscopy       Date:  2006-06       Impact factor: 4.772

4.  Biomechanical evaluation of rotator cuff repairs in a sheep model: suture anchors using arthroscopic Mason-Allen stitches compared with transosseous sutures using traditional modified Mason-Allen stitches.

Authors:  Hans-Michael Klinger; Gottfried H Buchhorn; Gabert Heidrich; Enrico Kahl; Mike H Baums
Journal:  Clin Biomech (Bristol, Avon)       Date:  2007-12-03       Impact factor: 2.063

5.  Structural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts.

Authors:  H E Magen; S M Howell; M L Hull
Journal:  Am J Sports Med       Date:  1999 Jan-Feb       Impact factor: 6.202

6.  Cyclic loading biomechanical analysis of the pullout strengths of rotator cuff and glenoid anchors: 2013 update.

Authors:  F Alan Barber; Morley A Herbert
Journal:  Arthroscopy       Date:  2013-04-02       Impact factor: 4.772

7.  Better outcome for suture button compared with single syndesmotic screw for syndesmosis injury: five-year results of a randomized controlled trial.

Authors:  Benedikte W Ræder; Wender Figved; Jan E Madsen; Frede Frihagen; Silje B Jacobsen; Mette Renate Andersen
Journal:  Bone Joint J       Date:  2020-02       Impact factor: 5.082

8.  Liquifying PLDLLA Anchor Fixation in Achilles Reconstruction for Insertional Tendinopathy.

Authors:  Stephanie A Boden; Allison L Boden; Danielle Mignemi; Jason T Bariteau
Journal:  Foot Ankle Spec       Date:  2017-11-14

9.  Use of Ultrasonically Interdigitated Anchors in Haglund's Deformity Correction Surgery.

Authors:  Brittney Warren; Natalie Black; Laura Linscheid; Vinod Panchbhavi; Cory Janney
Journal:  Foot Ankle Spec       Date:  2020-03-04

10.  Arthroscopic anterior talofibular ligament repair for chronic ankle instability with a suture anchor technique.

Authors:  Eung Soo Kim; Kyung Tai Lee; Jun Sic Park; Young Koo Lee
Journal:  Orthopedics       Date:  2011-04-11       Impact factor: 1.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.