Cyclic testing of pullout sutures and micro-mitek suture anchors in flexor digitorum profundus tendon distal fixation.

K Latendresse1, E Dona, P J Scougall, F B Schreuder, Emma Puchert, William R Walsh.   

Abstract

PURPOSE: Little data exist comparing the strength of traditional methods of fixation in a flexor digitorum profundus tendon with the use of a suture anchor. In vitro cyclic testing simulating a passive mobilization protocol was used to compare the repair of a flexor digitorum profundus tendon using a single micro-Mitek anchor (Mitek, Westwood, MA) or a modified Bunnell 2-strand pullout technique using a monofilament or a braided polyester suture.
METHODS: Twenty-four fresh-frozen cadaveric fingers were divided randomly into 4 repair groups (n = 6 each): a micro-Mitek with a 3-0 braided polyester suture or a 3-0 monofilament suture, or a modified Bunnell technique with a 3-0 braided polyester suture or a 3-0 monofilament suture. After repair the specimens were loaded cyclically from 2 to 15 N at 5 N/s, for a total of 500 cycles. Gap formation at the tendon-bone interface was assessed every 100 cycles. Samples were tested to failure at the completion of 500 cycles.
RESULTS: No specimens failed catastrophically during cyclic testing. A significantly greater gap formed using the monofilament sutures compared with the braided polyester sutures with both repair techniques. Load to failure in the modified Bunnell technique was superior to the micro-Mitek with both suture types. The modified Bunnell technique using a braided polyester suture was superior to the monofilament suture whereas the suture type did not alter the properties of the micro-Mitek repair.
CONCLUSIONS: Significant gap formation with the use of a monofilament suture may be of concern. The use of a braided polyester suture when removal of the pullout suture is required as in the Bunnell technique also needs to be considered.

Mesh:

Substances:

Year:  2005        PMID: 15925154     DOI: 10.1016/j.jhsa.2004.10.014

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  5 in total

1.  Inflammatory response with osteolysis related to a bioabsorbable anchor in the finger: a case report.

Authors:  Gregory J Galano; Kevin N Jiang; Robert J Strauch; Melvin P Rosenwasser; Peter Tang
Journal:  Hand (N Y)       Date:  2009-11-07

2.  Mechanical properties of the flexor digitorum profundus tendon attachment.

Authors:  Jerrod J Felder; Loredana M Guseila; Archana Saranathan; Timothy J Shary; Steven B Lippitt; John J Elias
Journal:  J Hand Microsurg       Date:  2013-06-02

Review 3.  Finger Injuries in Football and Rugby.

Authors:  Kate E Elzinga; Kevin C Chung
Journal:  Hand Clin       Date:  2017-02       Impact factor: 1.907

4.  Initial Experience With a Bioresorbable Polymer Anchor.

Authors:  Robert R Burnham; Jayanth Kumar; Michael Pinzur; Adam Schiff
Journal:  Cureus       Date:  2020-12-29

5.  Introduction of a new repair technique in bony avulsion of the FDP tendon: A biomechanical study.

Authors:  Gabriel Halát; Lukas L Negrin; Ewald Unger; Thomas Koch; Johannes Streicher; Jochen Erhart; Patrick Platzer; Stefan Hajdu
Journal:  Sci Rep       Date:  2018-07-02       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.