Can maxilla and mandible bone quality explain differences in orthodontic mini-implant failures?

Omar Melendres Ugarte1, Ivan Onone Gialain1, Naor Maldonado de Carvalho1, Gisele Lie Fukuoka1, Rafael Yague Ballester1, Paolo Maria Cattaneo2, Marina Guimarães Roscoe1, Josete Barbosa Cruz Meira1.   

Abstract

Purpose: This study aimed to compare the risk of orthodontic mini-implant (OMI) failure between maxilla and mandible. A critical analysis of finite-element studies was used to explain the contradiction of the greatest clinical success for OMIs placed in the maxilla, despite the higher quality bone of mandible. Materials and
Methods: Four tridimensional FE models were built, simulating an OMI inserted in a low-dense maxilla, control maxilla, control mandible, and high-dense mandible. A horizontal force was applied to simulate an anterior retraction of 2 N (clinical scenario) and 10 N (overloading condition). The intra-bone OMI displacement and the major principal bone strains were used to evaluate the risk of failure due to insufficient primary stability or peri-implant bone resorption.
Results: The OMI displacement was far below the 50-100 µm threshold, suggesting that the primary stability would be sufficient in all models. However, the maxilla was more prone to lose its stability due to overload conditions, especially in the low-dense condition, in which major principal bone strains surpassed the pathologic bone resorption threshold of 3000 µstrain. Conclusions: The differences in orthodontic mini-implant failures cannot be explained by maxilla and mandible bone quality in finite-element analysis that does not incorporate the residual stress due to OMI insertion.
© 2020 The Author(s). Published by Informa UK Limited, trading as Taylor & Francis Group.

Entities:  

Keywords:  Orthodontic mini-implants; finite-element analysis; peri-implant bone resorption; primary stability

Year:  2021        PMID: 33521649      PMCID: PMC7808375          DOI: 10.1080/26415275.2020.1863155

Source DB:  PubMed          Journal:  Biomater Investig Dent        ISSN: 2641-5275


  30 in total

1.  Recommended placement torque when tightening an orthodontic mini-implant.

Authors:  Mitsuru Motoyoshi; Masayuki Hirabayashi; Miwa Uemura; Noriyoshi Shimizu
Journal:  Clin Oral Implants Res       Date:  2006-02       Impact factor: 5.977

2.  Mechanical characteristics of various orthodontic mini-screws in relation to artificial cortical bone thickness.

Authors:  Young-Youn Song; Jung-Yul Cha; Chung-Ju Hwang
Journal:  Angle Orthod       Date:  2007-11       Impact factor: 2.079

3.  Three-dimensional finite element analysis of the stability of mini-implants close to the roots of adjacent teeth upon application of bite force.

Authors:  Guanjun Zhou; Xiaoli Zhang; Hui Qie; Chenxi Li; Lin Lu; Lihua Shan
Journal:  Dent Mater J       Date:  2018-09-14       Impact factor: 2.102

4.  Success rates of a skeletal anchorage system in orthodontics: A retrospective analysis.

Authors:  Raymond Lam; Mithran S Goonewardene; Brent P Allan; Junji Sugawara
Journal:  Angle Orthod       Date:  2017-10-20       Impact factor: 2.079

Review 5.  Considerations preliminary to the application of early and immediate loading protocols in dental implantology.

Authors:  S Szmukler-Moncler; A Piattelli; G A Favero; J H Dubruille
Journal:  Clin Oral Implants Res       Date:  2000-02       Impact factor: 5.977

6.  Insertion Torques of Self-Drilling Mini-Implants in Simulated Mandibular Bone: Assessment of Potential for Implant Fracture.

Authors:  Yara K Hosein; Angie Smith; Cynthia E Dunning; Ali Tassi
Journal:  Int J Oral Maxillofac Implants       Date:  2016 May-Jun       Impact factor: 2.804

Review 7.  Failure rates and associated risk factors of orthodontic miniscrew implants: a meta-analysis.

Authors:  Spyridon N Papageorgiou; Ioannis P Zogakis; Moschos A Papadopoulos
Journal:  Am J Orthod Dentofacial Orthop       Date:  2012-11       Impact factor: 2.650

8.  Treatment outcome with orthodontic aligners and fixed appliances: a systematic review with meta-analyses.

Authors:  Spyridon N Papageorgiou; Despina Koletsi; Anna Iliadi; Timo Peltomaki; Theodore Eliades
Journal:  Eur J Orthod       Date:  2020-06-23       Impact factor: 3.075

9.  Comparison of Anchorage Efficiency of Orthodontic Mini-implant and Conventional Anchorage Reinforcement in Patients Requiring Maximum Orthodontic Anchorage: A Systematic Review and Meta-analysis.

Authors:  Yan Liu; Zhen-Jin Yang; Jing Zhou; Ping Xiong; Quan Wang; Yan Yang; Yu Hu; Jiang-Tian Hu
Journal:  J Evid Based Dent Pract       Date:  2020-01-29       Impact factor: 5.267

10.  Investigation of the optimal design of orthodontic mini-implants based on the primary stability: A finite element analysis.

Authors:  Amir Hooman Sadr Haghighi; Vahid Pouyafar; Ali Navid; Mahsa Eskandarinezhad; Tannaz Abdollahzadeh Baghaei
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2019-08-14
View more