Literature DB >> 33510931

Effect of Sample Volume Variation and Delay in Analysis on Plasma Glucose Concentration in Sri Lankan Healthy Adults.

Isuru Anupama Dharmasena1, Deepani Siriwardhana2, Anoja Priyadarshani Attanayake3.   

Abstract

The correct volume of sample and time of storing prior to the analysis are important considerations in the estimation of plasma glucose concentration of patients. The present study was to determine the effect of sample volume variation and time delay in the analysis of plasma glucose results in healthy adults. A total of 30 individuals aged between 20 and 30 years were selected for the study. Blood samples were collected into three fluoride-oxalate collection tubes separately. The results revealed that the sample volume variation from 2.0 mL fluoride-oxalate tube to 1.0 mL and 3.0 mL did not significantly affect the plasma glucose concentration (p > 0.05). However, the plasma glucose concentration in the sample significantly decreased upon delaying the analysis. The mean fasting plasma glucose concentration of analysis after one hour of collection and analysis after three hours of collection was not significantly different (p > 0.05). The mean fasting plasma glucose concentrations between one hour and five hours timepoints after collection (p < 0.001) and between three hours and five hours after collection (p = 0.014) were significantly different. In conclusion, overfilling and underfilling (2.0 ± 1.0 mL) of fluoride-oxalate tubes did not affect the plasma glucose results significantly. If the samples are analyzed within three hours of collection, the time dependent change too is not statistically significant.
Copyright © 2021 Isuru Anupama Dharmasena et al.

Entities:  

Year:  2021        PMID: 33510931      PMCID: PMC7822684          DOI: 10.1155/2021/6061206

Source DB:  PubMed          Journal:  Scientifica (Cairo)        ISSN: 2090-908X


  10 in total

1.  METHODS FOR ESTIMATION OF BLOOD GLUCOSE : A COMPARATIVE EVALUATION.

Authors:  Vivek N Ambade; Y V Sharma; B L Somani
Journal:  Med J Armed Forces India       Date:  2017-06-26

2.  Exploring the initial steps of the testing process: frequency and nature of pre-preanalytic errors.

Authors:  Paolo Carraro; Tatiana Zago; Mario Plebani
Journal:  Clin Chem       Date:  2011-12-28       Impact factor: 8.327

3.  Stabilization of glucose in blood samples: out with the old, in with the new.

Authors:  Raymond Gambino; David E Bruns
Journal:  Clin Chem Lab Med       Date:  2013-10       Impact factor: 3.694

Review 4.  Pre-analytical and analytical aspects affecting clinical reliability of plasma glucose results.

Authors:  Sara Pasqualetti; Federica Braga; Mauro Panteghini
Journal:  Clin Biochem       Date:  2017-03-11       Impact factor: 3.281

Review 5.  Diabetes Mellitus: Screening and Diagnosis.

Authors:  Karly Pippitt; Marlana Li; Holly E Gurgle
Journal:  Am Fam Physician       Date:  2016-01-15       Impact factor: 3.292

6.  Determination of blood glucose using an oxidase-peroxidase system with a non-carcinogenic chromogen.

Authors:  P Trinder
Journal:  J Clin Pathol       Date:  1969-03       Impact factor: 3.411

7.  Glycolysis inhibitors negatively bias blood glucose measurements: potential impact on the reported prevalence of diabetes mellitus.

Authors:  W S Waring; L E Evans; C T Kirkpatrick
Journal:  J Clin Pathol       Date:  2007-07       Impact factor: 3.411

8.  What is the most suitable blood collection tube for glucose estimation?

Authors:  Goce Dimeski; Kong S Yow; Nigel N Brown
Journal:  Ann Clin Biochem       Date:  2014-07-07       Impact factor: 2.057

9.  The impact of differences in plasma glucose between glucose oxidase and hexokinase methods on estimated gestational diabetes mellitus prevalence.

Authors:  Lynnsay M Dickson; Eckhart J Buchmann; Charl Janse Van Rensburg; Shane A Norris
Journal:  Sci Rep       Date:  2019-05-10       Impact factor: 4.379

10.  Impact of blood sample collection and processing methods on glucose levels in community outreach studies.

Authors:  Michael Turchiano; Cuong Nguyen; Arthur Fierman; Mark Lifshitz; Antonio Convit
Journal:  J Environ Public Health       Date:  2013-01-10
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.