What is the most suitable blood collection tube for glucose estimation?

Goce Dimeski1, Kong S Yow2, Nigel N Brown2.   

Abstract

OBJECTIVES: Glucose is one of the most frequently measured analytes in laboratories. Most recent studies on glucose stabilities confirm that the sodium fluoride/potassium oxalate (NaF/KOx) tube is far from the gold standard. Citrate tubes have been suggested as the preferred tube type by many institutions. Greiner has introduced a glucose-specific tube (Glucomedics) containing NaF/KOx, citrate, and EDTA to minimise glycolysis. The aim was to determine which tube would be the most suitable for accurate glucose estimation in a routine laboratory setting. DESIGN AND METHODS: The study process involved three experiments: (a) participant comparison using lithium heparin plasma as the comparative sample; (b) stability study (0, 1, 2 and 4 h); and (c) minimal fill volume for the citrate and the Glucomedics tubes.
RESULTS: The patient comparison study of lithium heparin plasma showed that EDTA, NaF/KOx, and both citrate and Glucomedics if corrected for dilutional factors produced acceptable results. The stability study up to 4 h showed that the Glucomedics tube was most effective in preventing clinically significant change in glucose concentration at a room temperature. Both citrate and Glucomedics need to be filled within 0.5 mL of the recommended fill volume for acceptable results.
CONCLUSION: The Glucomedics tube is the most suitable for minimising glycolysis. Further improvements to it (use of correct dilutional factor and the addition of gel separator) would make this tube the benchmark for the most accurate estimation, best diagnosis and patient care decisions.
© The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

Entities:  

Keywords:  Glucomedics; Glucose; NaF/KOx; citrate

Mesh:

Substances:

Year:  2014        PMID: 25002707     DOI: 10.1177/0004563214544708

Source DB:  PubMed          Journal:  Ann Clin Biochem        ISSN: 0004-5632            Impact factor:   2.057


  7 in total

Review 1.  Approach to hypoglycemia in infants and children.

Authors:  Kajal Gandhi
Journal:  Transl Pediatr       Date:  2017-10

2.  Overcoming preanalytical issues for diagnosing diabetes with fasting plasma glucose.

Authors:  Martina Montagnana; Giuseppe Lippi
Journal:  Ann Transl Med       Date:  2017-06

3.  Effectiveness of citrate buffer-fluoride mixture in Terumo tubes as an inhibitor of in vitro glycolysis.

Authors:  Graziella Bonetti; Mariarosa Carta; Martina Montagnana; Claudia Lo Cascio; Anna Rita Bonfigli; Andrea Mosca; Roberto Testa
Journal:  Biochem Med (Zagreb)       Date:  2016       Impact factor: 2.313

4.  Comparison of Three Blood Collection Tubes for 35 Biochemical Analytes: The Becton Dickinson Barricor Tube, Serum Separating Tube, and Plasma Separating Tube.

Authors:  Sunghwan Shin; Jongwon Oh; Hyung-Doo Park
Journal:  Ann Lab Med       Date:  2020-08-25       Impact factor: 3.464

5.  Effect of Sample Volume Variation and Delay in Analysis on Plasma Glucose Concentration in Sri Lankan Healthy Adults.

Authors:  Isuru Anupama Dharmasena; Deepani Siriwardhana; Anoja Priyadarshani Attanayake
Journal:  Scientifica (Cairo)       Date:  2021-01-15

Review 6.  Validation of biomarkers of food intake-critical assessment of candidate biomarkers.

Authors:  L O Dragsted; Q Gao; A Scalbert; G Vergères; M Kolehmainen; C Manach; L Brennan; L A Afman; D S Wishart; C Andres Lacueva; M Garcia-Aloy; H Verhagen; E J M Feskens; G Praticò
Journal:  Genes Nutr       Date:  2018-05-30       Impact factor: 5.523

7.  The new Greiner FC-Mix tubes equal the old Terumo ones and are useful as glucose stabilizer after prolonged storage of samples.

Authors:  Graziella Bonetti; Mariarosa Carta
Journal:  Biochem Med (Zagreb)       Date:  2017-08-28       Impact factor: 2.313

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.