Literature DB >> 33510551

Recommended Practice for Thrust Measurement in Electric Propulsion Testing.

James E Polk1, Anthony Pancotti2, Thomas Haag3, Scott King4, Mitchell Walker5, Joseph Blakely6, John Ziemer7.   

Abstract

Accurate, direct measurement of thrust or impulse is one of the most critical elements of electric thruster characterization, and one of the most difficult measurements to make. This paper summarizes recommended practices for the design, calibration, and operation of pendulum thrust stands, which are widely recognized as the best approach for measuring μN- to mN-level thrust and μNs-level impulse bits. The fundamentals of pendulum thrust stand operation are reviewed, along with the implementation of hanging pendulum, inverted pendulum, and torsional balance configurations. Methods of calibration and recommendations for calibration processes are presented. Sources of error are identified and methods for data processing and uncertainty analysis are discussed. This review is intended to be the first step toward a recommended practices document to help the community produce high quality thrust measurements.

Entities:  

Year:  2017        PMID: 33510551      PMCID: PMC7839308          DOI: 10.2514/1.B35564

Source DB:  PubMed          Journal:  J Propuls Power        ISSN: 0748-4658            Impact factor:   1.500


  5 in total

1.  A torsion balance for impulse and thrust measurements of micro-Newton thrusters.

Authors:  Yuan-Xia Yang; Liang-Cheng Tu; Shan-Qing Yang; Jun Luo
Journal:  Rev Sci Instrum       Date:  2012-01       Impact factor: 1.523

2.  Comparison of electrostatic fins with piezoelectric impact hammer techniques to extend impulse calibration range of a torsional thrust stand.

Authors:  Anthony P Pancotti; Matthew Gilpin; Martin S Hilario
Journal:  Rev Sci Instrum       Date:  2012-03       Impact factor: 1.523

3.  Thrust stand for vertically oriented electric propulsion performance evaluation.

Authors:  Trevor Moeller; Kurt A Polzin
Journal:  Rev Sci Instrum       Date:  2010-11       Impact factor: 1.523

4.  High-power, null-type, inverted pendulum thrust stand.

Authors:  Kunning G Xu; Mitchell L R Walker
Journal:  Rev Sci Instrum       Date:  2009-05       Impact factor: 1.523

5.  Precision electromagnetic calibration technique for micro-Newton thrust stands.

Authors:  Zhen He; Jianjun Wu; Daixian Zhang; Gaofei Lu; Zejun Liu; Rui Zhang
Journal:  Rev Sci Instrum       Date:  2013-05       Impact factor: 1.523

  5 in total
  2 in total

1.  Crossing Frequency Method Applicable to Intermediate Pressure Plasma Diagnostics Using the Cutoff Probe.

Authors:  Si-Jun Kim; Jang-Jae Lee; Young-Seok Lee; Chul-Hee Cho; Shin-Jae You
Journal:  Sensors (Basel)       Date:  2022-02-08       Impact factor: 3.576

2.  Development of a High-Linearity Voltage and Current Probe with a Floating Toroidal Coil: Principle, Demonstration, Design Optimization, and Evaluation.

Authors:  Si-Jun Kim; In-Ho Seong; Young-Seok Lee; Chul-Hee Cho; Won-Nyoung Jeong; Ye-Bin You; Jang-Jae Lee; Shin-Jae You
Journal:  Sensors (Basel)       Date:  2022-08-05       Impact factor: 3.847

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.