Literature DB >> 33500471

Metal artefact reduction of different alloys with dual energy computed tomography (DECT).

Anand John Vellarackal1, Achim Hermann Kaim2,3.   

Abstract

To evaluate the influence of dual-energy CT (DECT) and Virtual monochromatic spectral (VMS) imaging on: (1) the artefact size of geometrically identical orthopaedic implants consisting of three different compositions and (2) the image quality of the surrounding bone, three similar phantoms-each featuring one femoral stem composed of either titanium, chrome-cobalt or stainless steel surrounded by five calcium pellets (200 mg hydroxyapatite/calcium carbonate) to simulate bony tissue and one reference pellet located away from the femoral stem-were built. DECT with two sequential scans (80 kVp and 140 kVp; scan-to-scan technique) was performed, and VMS images were calculated between 40 and 190 keV. The artefact sizes were measured volumetrically by semiautomatic selection of regions of interest (ROIs), considering the VMS energies and the polychromatic spectres. Moreover, density and image noise within the pellets were measured. All three phantoms exhibit artefact size reduction as energy increases from 40 to 190 keV. Titanium exhibited a stronger reduction than chrome-cobalt and stainless steel. The artefacts were dependent on the diameter of the stem. Image quality increases with higher energies on VMS with a better depiction of surrounding structures. Monoenergetic energies 70 keV and 140 keV demonstrate superior image quality to those produced by spectral energies 80 kVp and 140 kVp.

Entities:  

Year:  2021        PMID: 33500471      PMCID: PMC7838173          DOI: 10.1038/s41598-021-81600-1

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.379


  22 in total

Review 1.  Dual-Energy CT: Basic Principles, Technical Approaches, and Applications in Musculoskeletal Imaging (Part 1).

Authors:  Patrick Omoumi; Fabio Becce; Damien Racine; Julien G Ott; Gustav Andreisek; Francis R Verdun
Journal:  Semin Musculoskelet Radiol       Date:  2015-12-22       Impact factor: 1.777

2.  Dual-energy (spectral) CT: applications in abdominal imaging.

Authors:  Alvin C Silva; Brian G Morse; Amy K Hara; Robert G Paden; Norio Hongo; William Pavlicek
Journal:  Radiographics       Date:  2011 Jul-Aug       Impact factor: 5.333

3.  Dual energy CT: how well can pseudo-monochromatic imaging reduce metal artifacts?

Authors:  Stefan Kuchenbecker; Sebastian Faby; Stefan Sawall; Michael Lell; Marc Kachelrieß
Journal:  Med Phys       Date:  2015-02       Impact factor: 4.071

Review 4.  Dual-energy CT-based monochromatic imaging.

Authors:  Lifeng Yu; Shuai Leng; Cynthia H McCollough
Journal:  AJR Am J Roentgenol       Date:  2012-11       Impact factor: 3.959

5.  Dual-energy CT: general principles.

Authors:  Thorsten R C Johnson
Journal:  AJR Am J Roentgenol       Date:  2012-11       Impact factor: 3.959

Review 6.  Virtual monochromatic spectral imaging with fast kilovoltage switching: reduction of metal artifacts at CT.

Authors:  Eric Pessis; Raphaël Campagna; Jean-Michel Sverzut; Fabienne Bach; Mathieu Rodallec; Henri Guerini; Antoine Feydy; Jean-Luc Drapé
Journal:  Radiographics       Date:  2013 Mar-Apr       Impact factor: 5.333

7.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

Review 8.  Reduction of Metal Artifact with Dual-Energy CT: Virtual Monospectral Imaging with Fast Kilovoltage Switching and Metal Artifact Reduction Software.

Authors:  Eric Pessis; Jean-Michel Sverzut; Raphaël Campagna; Henri Guerini; Antoine Feydy; Jean-Luc Drapé
Journal:  Semin Musculoskelet Radiol       Date:  2015-12-22       Impact factor: 1.777

Review 9.  Metal artifact reduction techniques in musculoskeletal CT-imaging.

Authors:  R H H Wellenberg; E T Hakvoort; C H Slump; M F Boomsma; M Maas; G J Streekstra
Journal:  Eur J Radiol       Date:  2018-08-12       Impact factor: 3.528

10.  Obtaining dual-energy computed tomography (CT) information from a single-energy CT image for quantitative imaging analysis of living subjects by using deep learning.

Authors:  Wei Zhao; Tianling Lv; Rena Lee; Yang Chen; Lei Xing
Journal:  Pac Symp Biocomput       Date:  2020
View more
  2 in total

Review 1.  Improving radiation physics, tumor visualisation, and treatment quantification in radiotherapy with spectral or dual-energy CT.

Authors:  Matthijs Ferdinand Kruis
Journal:  J Appl Clin Med Phys       Date:  2021-11-07       Impact factor: 2.102

2.  Dual-Energy Computed Tomography Imaging in Early-Stage Hepatocellular Carcinoma: A Preliminary Study.

Authors:  Jinping Li; Sheng Zhao; Zaisheng Ling; Daqing Li; Guangsheng Jia; Chenglei Zhao; Xue Lin; Yanmei Dai; Huijie Jiang; Song Wang
Journal:  Contrast Media Mol Imaging       Date:  2022-01-04       Impact factor: 3.161

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.