Literature DB >> 26020610

Sub-100 ps coincidence time resolution for positron emission tomography with LSO:Ce codoped with Ca.

Mythra Varun Nemallapudi1, Stefan Gundacker, Paul Lecoq, Etiennette Auffray, Alessandro Ferri, Alberto Gola, Claudio Piemonte.   

Abstract

The coincidence time resolution (CTR) becomes a key parameter of 511 keV gamma detection in time of flight positron emission tomography (TOF-PET). This is because additional information obtained through timing leads to a better noise suppression and therefore a better signal to noise ratio in the reconstructed image. In this paper we present the results of CTR measurements on two different SiPM technologies from FBK coupled to LSO:Ce codoped 0.4%Ca crystals. We compare the measurements performed at two separate test setups, i.e. at CERN and at FBK, showing that the obtained results agree within a few percent. We achieve a best CTR value of 85 ± 4 ps FWHM for 2 × 2 × 3 mm(3) LSO:Ce codoped 0.4%Ca crystals, thus breaking the 100 ps barrier with scintillators similar to LSO:Ce or LYSO:Ce. We also demonstrate that a CTR of 140 ± 5 ps can be achieved for longer 2 × 2 × 20 mm(3) crystals, which can readily be implemented in the current generation PET systems to achieve the desired increase in the signal to noise ratio.

Mesh:

Substances:

Year:  2015        PMID: 26020610     DOI: 10.1088/0031-9155/60/12/4635

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  24 in total

1.  Can PET be performed without an attenuation scan?

Authors:  Colin Jones; Ran Klein
Journal:  J Nucl Cardiol       Date:  2015-09-04       Impact factor: 5.952

Review 2.  Innovations in Instrumentation for Positron Emission Tomography.

Authors:  Eric Berg; Simon R Cherry
Journal:  Semin Nucl Med       Date:  2018-03-12       Impact factor: 4.446

3.  Improving timing performance of double-ended readout in TOF-PET detectors.

Authors:  L Guo; J Tian; P Chen; S E Derenzo; W-S Choong
Journal:  J Instrum       Date:  2020-01-02       Impact factor: 1.415

Review 4.  Photon counting detectors and their applications ranging from particle physics experiments to environmental radiation monitoring and medical imaging.

Authors:  Ryosuke Ota
Journal:  Radiol Phys Technol       Date:  2021-03-19

5.  Advances in imaging instrumentation for nuclear cardiology.

Authors:  Jae Sung Lee; Gil Kovalski; Tali Sharir; Dong Soo Lee
Journal:  J Nucl Cardiol       Date:  2017-07-17       Impact factor: 5.952

6.  An integrated model of scintillator-reflector properties for advanced simulations of optical transport.

Authors:  Emilie Roncali; Mariele Stockhoff; Simon R Cherry
Journal:  Phys Med Biol       Date:  2017-04-11       Impact factor: 3.609

7.  Reaching 200-ps timing resolution in a time-of-flight and depth-of-interaction positron emission tomography detector using phosphor-coated crystals and high-density silicon photomultipliers.

Authors:  Sun Il Kwon; Alessandro Ferri; Alberto Gola; Eric Berg; Claudio Piemonte; Simon R Cherry; Emilie Roncali
Journal:  J Med Imaging (Bellingham)       Date:  2016-11-23

8.  Two-crossed-polarizers based optical property modulation method for ionizing radiation detection for positron emission tomography.

Authors:  Yuli Wang; Yingjie Li; Fei Yi; Junyu Li; Siwei Xie; Qiyu Peng; Jianfeng Xu
Journal:  Phys Med Biol       Date:  2019-07-05       Impact factor: 3.609

Review 9.  Advances in PET/MR instrumentation and image reconstruction.

Authors:  Jorge Cabello; Sibylle I Ziegler
Journal:  Br J Radiol       Date:  2016-07-22       Impact factor: 3.039

10.  Using convolutional neural networks to estimate time-of-flight from PET detector waveforms.

Authors:  Eric Berg; Simon R Cherry
Journal:  Phys Med Biol       Date:  2018-01-11       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.