Micro computed tomography evaluation of Invisalign aligner thickness homogeneity.

Edoardo Mantovani, Simone Parrini, Emanuele Coda, Giovanni Cugliari, Nicola Scotti, Damiano Pasqualini, Andrea Deregibus, Tommaso Castroflorio.   

Abstract

OBJECTIVES: To measure the thickness homogeneity of Invisalign (Align Technology Inc, San José, Calif) aligners with micro-computed tomography (micro-CT) scans.
MATERIALS AND METHODS: Starting from micro-CT scanning of 20 different aligners, multiplanar reconstructions were obtained. An orthodontist blinded about the study measured aligner thickness in different regions (molar, canine, incisor) and in different sites (gingival-buccal, buccal, occlusal, lingual, and gingival-lingual). To assess various thicknesses in different aligner sites and regions, the sample was stratified into subgroups and linear regression analysis was performed.
RESULTS: Descriptive analysis showed that mean thickness of aligners in the incisor region ranged from 0.582 mm to 0.639 mm, in the canine region from 0.569 mm to 0.644 mm, and in the molar region from 0.566 mm to 0.634 mm. Student's t-tests showed no significant differences in the aligner thickness of different regions when data were stratified by different sites. Student's t-tests showed significant differences in thickness homogeneity for the molar region when the data were stratified by tooth (mean difference = 0.068 mm; 95% confidence interval, 0.009-0.126 mm; P = .024).
CONCLUSIONS: Invisalign aligner thickness is characterized by small differences. The only significant difference was revealed in the molar region where thickness of the gingival-lingual edge is significantly thinner than that measured at the occlusal aspect. From a clinical perspective, the results of the present study could be considered to explain the reduced predictability of several orthodontic tooth movements in the molar region.
© 2021 by The EH Angle Education and Research Foundation, Inc.

Entities:  

Keywords:  Aligners; Thickness

Mesh:

Year:  2021        PMID: 33476365      PMCID: PMC8084474          DOI: 10.2319/040820-265.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  30 in total

1.  Influence of thermoplastic appliance thickness on the magnitude of force delivered to a maxillary central incisor during tipping.

Authors:  Wolfram Hahn; Henning Dathe; Julia Fialka-Fricke; Susanne Fricke-Zech; Antonia Zapf; Dietmar Kubein-Meesenburg; Reza Sadat-Khonsari
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-07       Impact factor: 2.650

Review 2.  Efficacy of clear aligners in controlling orthodontic tooth movement: a systematic review.

Authors:  Gabriele Rossini; Simone Parrini; Tommaso Castroflorio; Andrea Deregibus; Cesare L Debernardi
Journal:  Angle Orthod       Date:  2014-11-20       Impact factor: 2.079

Review 3.  Forces and moments generated by aligner-type appliances for orthodontic tooth movement: A systematic review and meta-analysis.

Authors:  Anna Iliadi; Despina Koletsi; Theodore Eliades
Journal:  Orthod Craniofac Res       Date:  2019-07-09       Impact factor: 1.826

4.  Forces and moments delivered by the PET-G aligner to a maxillary central incisor for palatal tipping and intrusion.

Authors:  Lixia Gao; Andrea Wichelhaus
Journal:  Angle Orthod       Date:  2017-02-06       Impact factor: 2.079

5.  Mechanical properties of "two generations" of teeth aligners: Change analysis during oral permanence.

Authors:  Roberta Condo'; Luca Pazzini; Loredana Cerroni; Guido Pasquantonio; Giuseppina Lagana'; Alessandro Pecora; Valentina Mussi; Antonio Rinaldi; Barbara Mecheri; Silvia Licoccia; Luca Maiolo
Journal:  Dent Mater J       Date:  2018-07-12       Impact factor: 2.102

6.  In vitro cytotoxicity of different thermoplastic materials for clear aligners.

Authors:  Stefano Martina; Roberto Rongo; Rosaria Bucci; Armando Viviano Razionale; Rosa Valletta; Vincenzo D'Antò
Journal:  Angle Orthod       Date:  2019-04-04       Impact factor: 2.079

7.  Incidence of white spot lesions among patients treated with clear aligners and traditional braces.

Authors:  Peter H Buschang; David Chastain; Cameron L Keylor; Doug Crosby; Katie C Julien
Journal:  Angle Orthod       Date:  2018-12-17       Impact factor: 2.079

8.  Mechanical load exerted by PET-G aligners during mesial and distal derotation of a mandibular canine : An in vitro study.

Authors:  F Elkholy; B Mikhaiel; F Schmidt; B G Lapatki
Journal:  J Orofac Orthop       Date:  2017-09       Impact factor: 1.938

9.  Comparison of Pain Perception in Patients Affected by Cleft and Cranio Facial Anomalies Treated With Traditional Fixed Appliances or Invisalign.

Authors:  Maria Costanza Meazzini; Chiara Tortora; Fabio Mazzoleni; Luca Autelitano
Journal:  Cleft Palate Craniofac J       Date:  2019-07-15

10.  Patient satisfaction and quality of life status after 2 treatment modalities: Invisalign and conventional fixed appliances.

Authors:  Carlos Flores-Mir; Jeremy Brandelli; Camila Pacheco-Pereira
Journal:  Am J Orthod Dentofacial Orthop       Date:  2018-11       Impact factor: 2.650

View more
  2 in total

1.  Three-dimensional analysis of aligner gaps and thickness distributions, using hard x-ray tomography with micrometer resolution.

Authors:  Rémi Ammann; Christine Tanner; Georg Schulz; Bekim Osmani; Prasad Nalabothu; Tino Töpper; Bert Müller
Journal:  J Med Imaging (Bellingham)       Date:  2022-06-16

2.  Utilization of a 3D Printed Orthodontic Distalizer for Tooth-Borne Hybrid Treatment in Class II Unilateral Malocclusions.

Authors:  Andrej Thurzo; Wanda Urbanová; Bohuslav Novák; Iveta Waczulíková; Ivan Varga
Journal:  Materials (Basel)       Date:  2022-02-25       Impact factor: 3.623

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.