| Literature DB >> 33475827 |
Young-Kyun Kim1,2, So-Hyun Kim3, Tae-Hyun Choi3, Edwin H Yen4, Bingshuang Zou4, Yonsoo Shin3, Nam-Ki Lee5.
Abstract
OBJECTIVES: The purpose of this retrospective study was to evaluate the accuracy of intraoral scan (IOS) images in the maxillary and mandibular arches with orthodontic brackets.Entities:
Keywords: Accuracy; Digital impression; Intraoral scan images; Orthodontic brackets
Mesh:
Year: 2021 PMID: 33475827 PMCID: PMC8342351 DOI: 10.1007/s00784-021-03792-0
Source DB: PubMed Journal: Clin Oral Investig ISSN: 1432-6981 Impact factor: 3.573
Fig. 1Cohort diagram showing selection of intraoral scan images
Fig. 2Study workflow of intraoral scan (IOS) images taking, their superimposition, and analysis using the Geomagic software program. To evaluate the reproducibility of IOS images, IOS1 and IOS2 images scanned twice at 2-week intervals, were superimposed, and average surface errors between them [Δ IOS (1, 2)] were measured based on the first region of interest (ROI-1), which were established as the bucco-lingual surfaces of the entire teeth above the gingival line
Fig. 3Study workflow of intraoral scan (IOS) images taking, their superimposition, and analysis using the Geomagic software program. To assess trueness of the IOS after bracket bonding (IOSb) images, IOS1 and IOSb images were superimposed, and average surface errors [Δ IOS (1c, b)] were obtained based on the second ROI (ROI-2), which was the occluso-buccal surfaces of the teeth above the upper-most margin of the bracket bases and the lingual surfaces of the teeth. Also, the superimposed IOS1 and IOS2 images were cut according to ROI-2 and defined as IOSc images (IOS1c and IOS2c, respectively) for the comparison of the surface errors [Δ IOS (1c, 2c)]
Characteristics of IOS1, IOS2, and IOSb images
| IOS images | |||
|---|---|---|---|
| Dentition | IOS1 | IOS2 | IOSb |
| Maxilla ( | 14 | 14 | 14 |
| Mandible ( | 14 | 14 | 14 |
IOS1 first intraoral scan as pre-orthodontic digital impression; IOS2 second intraoral scan before bracket bonding; IOSb IOS with orthodontic brackets after bonding
Average surface errors and their reliability between repeated IOS images
| Dentition | Region | Average surface errors [Δ IOS (1, 2); unit, μm] | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Mean | SD | Max | Min | 95% CI | ICC [95% CI] | ||||
| Lower | Upper | ||||||||
| Maxilla | Total | 57 | 8 | 77 | 48 | 53 | 62 | n/a | 0.991 [0.934/0.999] |
| Anterior | 54 | 11 | 72 | 33 | 48 | 60 | 0.201 | 0.944 [0.580/0.994] | |
| Premolar | 54 | 12 | 71 | 18 | 47 | 61 | 0.447 [−1.715/0.936] | ||
| Molar | 63 | 13 | 86 | 46 | 56 | 71 | 0.435 [−4.091/0.941] | ||
| Mandible | Total | 59 | 14 | 82 | 35 | 51 | 67 | n/a | 0.907 [0.290/0.990] |
| Anterior | 55 | 14 | 81 | 38 | 47 | 63 | 0.262 | 0.983 [0.831/0.998] | |
| Premolar | 48 | 11 | 70 | 31 | 42 | 54 | 0.914 [0.373/0.991] | ||
| Molar | 61 | 21 | 97 | 33 | 49 | 73 | 0.911 [−0.013/0.991] | ||
Δ IOS (1, 2) the average surface errors, representing image difference obtained after superimposition and cutting of ISO1 and IOS2 images according to ROI-1; IOS1 first intraoral scan as pre-orthodontic digital impression; IOS2 second intraoral scan before bracket bonding; Total whole dentition; anterior, premolar, and molar regions were divided by contact points in the dentition after superimposition of the two images; Max maximum; Min minimum; CI confidence interval
*Kruskal Wallis test; n/a; not applicable; ICC, intraclass correlation coefficients; ICC > 0.8/0.6/0.4/0.2 represent almost perfect, substantial, moderate, or mediocre reliability, respectively
Reliability and conformity of the average surface errors among IOS1c, IOS2c, and IOSb images
| Reliability | Conformity | ||||
|---|---|---|---|---|---|
| ICC [95% CI] | CCC [95% CI] | ||||
| Δ IOS (1c, 2c) | Δ IOS (1c, b) | Δ IOS (2c, b) | Δ IOS (1c, 2c) | ||
| Maxilla | Total | 1.000 [0.997/1.000] | 0.013 [−0.457/0.478] | 0.014 [−0.458/0.479] | 0.999 [0.994/1.000] |
| Anterior | 0.999 [0.991/1.000] | 0.307 [−0.662/0.892] | 0.331 [−0.651/−0.535] | 0.997 [0.975/1.000] | |
| Premolar | 0.999 [0.996/1.000] | −0.342 [−0.882/0.586] | −0.330 [−0.877/0.591] | 0.999 [0.990/1.000] | |
| Molar | 0.995 [0.889/0.999] | −0.033 [−0.502/0.451] | −0.045 [−0.550/0.484] | 0.987 [0.948/0.997] | |
| Mandible | Total | 0.994 [0.878/0.999] | −0.641 [−0.894/−0.076] | −0.577 [−0.867/0.004] | 0.984 [0.923/0.997] |
| Anterior | 1.000 [0.998/1.000] | 0.538 [0.198/0.762] | 0.550 [0.207/0.773] | 1.000 [0.999/1.000] | |
| Premolar | 1.000 [1.000/1.000] | 0.600 [−0.115/0.905] | 0.604 [−0.102/0.906] | 1.000 [0.999/1.000] | |
| Molar | 0.989 [0.906/0.999] | −0.476 [−0.916/0.484] | −0.607 [−0.947/0.372] | 0.972 [0.785/0.843] | |
Δ IOS (1c, 2c) [or Δ IOS (1c, b), or Δ IOS (2c, b)] the average surface errors, representing image difference obtained after superimposition and cutting of the two IOS images according to ROI-2; ICC intraclass correlation coefficients; ICC > 0.8/0.6/0.4/0.2 represent almost perfect, substantial, moderate, or mediocre reliability, respectively; CCC Lin’s concordance correlation coefficients; CCC of > 0.8/0.6/0.4/0.2 or ≤ 0.2 represent almost perfect, substantial, moderate, mediocre, or low conformity, respectively; CI confidence interval
Fig. 4Bland-Altman plot of average surface errors among IOS1c, IOS2c, and IOSb images
Average surface errors among IOS1c, IOS2c, and IOSb images and their comparisons in the maxillary/mandibular dentition
| Dentition | Region | Average surface errors [Δ IOS (1c, 2c); unit, μm) | Average surface errors [Δ IOS (1c, b); unit, μm] | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mean | SD | Max | Min | 95% CI | Mean | SD | Max | Min | 95% CI | |||||||
| Lower | Upper | Lower | Upper | |||||||||||||
| Maxilla | Total | 55 | 10 | 69 | 40 | 49 | 60 | n/a | 97 | 28 | 150 | 57 | 81 | 112 | n/a | < 0.001 |
| Anterior | 45 | 9 | 61 | 34 | 39 | 50 | 0.274 | 93 | 40 | 209 | 44 | 70 | 117 | 0.944 | < 0.001 | |
| Premolar | 47 | 9 | 66 | 37 | 42 | 53 | 96 | 36 | 157 | 38 | 75 | 117 | < 0.001 | |||
| Molar | 53 | 14 | 77 | 38 | 45 | 61 | 91 | 39 | 159 | 10 | 68 | 113 | < 0.001 | |||
| Mandible | Total | 58 | 13 | 82 | 42 | 51 | 66 | n/a | 95 | 29 | 159 | 53 | 78 | 112 | n/a | < 0.001 |
| Anterior | 54 | 24 | 122 | 36 | 40 | 68 | 0.310 | 94 | 27 | 132 | 32 | 78 | 109 | 0.805 | < 0.001 | |
| Premolar | 45 | 12 | 74 | 31 | 38 | 52 | 101 | 63 | 294 | 35 | 65 | 138 | < 0.001 | |||
| Molar | 54 | 17 | 83 | 33 | 44 | 64 | 95 | 27 | 144 | 59 | 79 | 110 | < 0.001 | |||
Δ IOS (1c, 2c) [or Δ IOS (1c, b)] the average surface errors, representing image difference obtained after superimposition and cutting of the two IOS images according to ROI-2; Max maximum; Min minimum; CI confidence interval
*Kruskal Wallis test
†Mann Whitney U test; n/a not applicable
Average surface errors of IOS1c and 2c or IOSb and 1c images between maxillary and mandibular arches
| Region | Average surface errors [Δ IOS (1c, 2c); unit, μm] | Average surface errors [Δ IOS (1c, b); unit, μm] | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Maxilla | Mandible | Maxilla | Mandible | |||||||
| Mean | SD | Mean | SD | Mean | SD | Mean | SD | |||
| Total | 55 | 10 | 58 | 13 | 0.635 | 97 | 28 | 95 | 29 | 0.701 |
| Anterior | 45 | 9 | 54 | 24 | 0.352 | 93 | 40 | 94 | 27 | 0.401 |
| Premolar | 47 | 9 | 45 | 12 | 0.285 | 96 | 36 | 101 | 63 | 0.839 |
| Molar | 53 | 14 | 54 | 17 | 0.946 | 91 | 39 | 95 | 27 | 0.874 |
Δ IOS (1c, 2c) [or Δ IOS (1c, b)] the average surface errors, representing image difference obtained after superimposition and cutting of the two IOS images according to ROI-2
†Mann Whitney U test