Literature DB >> 33469702

The Use of Semi-Absorbable Mesh and its Impact on Donor-Site Morbidity and Patient-Reported Outcomes in DIEP Flap Breast Reconstruction.

L C Siegwart1, L Sieber1, S Fischer1, Y Diehm1, C Hirche1, U Kneser1, D Kotsougiani-Fischer2.   

Abstract

BACKGROUND: This study aimed to evaluate the impact of semi-absorbable mesh on donor-site morbidity and patient-reported outcomes in deep inferior epigastric perforator (DIEP) flap breast reconstruction.
METHODS: We conducted a retrospective cohort study of all patients who had DIEP flap breast reconstruction in our department from July 2007 to March 2019. Patients were invited to a comparative follow-up visit and grouped according to donor-site closure: primary fascial closure (the no-mesh group) and fascial reinforcement with semi-absorbable mesh in a subfascial position (the mesh group). The primary outcome of interest was donor-site morbidity, including bulging, hernia formation and rectus abdominis muscle strength. We also surveyed, surgical site complications and patient-reported outcomes using Patient and Observer Scar Assessment Scale v2.0 and BREAST-Q© version 2.0.
RESULTS: A total of 191 patients had received DIEP flap breast reconstruction. Eighty-five patients (44.5%) with 108 DIEP flaps (53 patients in the mesh group and 32 patients in the no-mesh group) were included in the study. The mean BMI of the patients was significantly higher in the mesh group (mesh group, 26.9 vs. no-mesh group, 25.0, with p = 0.03). The incidence of hernia was significantly reduced in the mesh group (mesh group, 2.8% vs. no-mesh group, 13.5%, with p = 0.03). The incidence of bulging and the extent of rectus abdominis muscle strength were similar for both groups. Operative surgical site complications were reduced in the mesh group (mesh group, 7.5% vs. no-mesh group, 18.8%). There was no difference in patients' physical well-being and satisfaction with the donor site between groups. Patient-reported scar outcome was significantly better in the no-mesh group (p < 0.001).
CONCLUSION: Our novel method of donor-site closure with semi-absorbable mesh in a subfascial position for reinforcement of the anterior rectus fascia on the DIEP donor site is safe. It has no negative impact on surgical site complications and patient-reported outcomes, while reducing the incidence of hernias on the donor-site in DIEP flap breast reconstruction. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

Entities:  

Keywords:  Breast reconstruction; DIEP; Donor-site morbidity; Hernia; Mesh

Mesh:

Year:  2021        PMID: 33469702     DOI: 10.1007/s00266-020-02096-0

Source DB:  PubMed          Journal:  Aesthetic Plast Surg        ISSN: 0364-216X            Impact factor:   2.326


  3 in total

Review 1.  The evolution of perforator flap breast reconstruction: twenty years after the first DIEP flap.

Authors:  Claragh Healy; Robert J Allen
Journal:  J Reconstr Microsurg       Date:  2013-10-25       Impact factor: 2.873

2.  A new classification system for muscle and nerve preservation in DIEP flap breast reconstruction.

Authors:  Bernard T Lee; Chen Chen; Minh-Doan Nguyen; Samuel J Lin; Adam M Tobias
Journal:  Microsurgery       Date:  2010       Impact factor: 2.425

3.  Mesh abdominal wall hernia surgery is safe and effective-the harm New Zealand media has done: response to Dr Steven Kelly's article.

Authors:  Robert Bendavid
Journal:  N Z Med J       Date:  2017-12-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.