| Literature DB >> 33458662 |
Fatih BaĞcier1, Duygu Geler KÜlcÜ2, Elem Yorulmaz2, Elif Çiğdem Altunok3.
Abstract
OBJECTIVES: This study aims to evaluate the intra- and inter-rater reliability coefficients of the supraspinatus tendon thickness, acromiohumeral distance, and occupation ratio in patients with shoulder impingement syndrome. PATIENTS AND METHODS: The study included 83 patients (21 males, 62 females; mean age 51.6±11.0 years; range, 26 to 70 years) with shoulder impingement syndrome. The supraspinatus tendon thickness, acromiohumeral distance, and occupation ratio values were obtained one week apart by two observers. The intraclass correlation coefficient (ICC), minimum detectable change, and standard error of measurement were calculated.Entities:
Keywords: Reliability; shoulder impingement syndrome; ultrasound
Year: 2020 PMID: 33458662 PMCID: PMC7788650 DOI: 10.46497/ArchRheumatol.2020.7515
Source DB: PubMed Journal: Arch Rheumatol ISSN: 2148-5046 Impact factor: 1.472
Demographic parameters of participants (n=83)
| n | % | Mean±SD | |
| Age (year) | 51.6±11.0 | ||
| Body mass index (kg/m2) | 26.0±4.8 | ||
| Sex | |||
| Male | 21 | 25.3 | |
| Females | 62 | 74.7 | |
| Occupation | |||
| Housewife | 45 | 54.2 | |
| Civil servant | 22 | 26.5 | |
| Worker | 2 | 2.4 | |
| Retired | 4 | 4.8 | |
| Pain duration (month) | 12.0±4.2 | ||
| Dominant side | |||
| Right | 79 | 95.2 | |
| Left | 4 | 4.8 | |
| Symptomatic side | |||
| Right | 54 | 65.1 | |
| Left | 29 | 34.9 | |
| SD: Standard deviation. | |||
Ultrasonographic measurements
| Observer 1 | Observer 2 | |
| Mean±SD | Mean±SD | |
| SsT thickness-1 (mm) | 6.5±0.9 | 6.5±0.9 |
| SsT thickness 2 (mm) | 6.4±0.9 | 6.6±0.9 |
| AHD-1 (mm) | 11.8±1.4 | 11.8±1.53 |
| AHD-2 (mm) | 13.2±1.3 | 13.19±1.26 |
| Occupation ratio-1 | 0.5±0.1 | 0.54±0.09 |
| Occupation ratio-2 | 0.5±0.1 | 0.55±0.09 |
| SD: Standard deviation; Acromiohumeral distance. SsT: Supraspinatus tendon; AHD: | ||
Intraclass correlation coefficients and standard error of mean of intra- and inter-rater reliability measurements
| Comparison | Statistic | SsT thickness | AHD | Occupation ratio |
| Intra-rater | ||||
| ICC | 0.914 | 0.943 | 0.916 | |
| Observer 1 | 95% CI | 0.871-0.944 | 0.914-0.963 | 0.873-0.945 |
| SEM (mm) | 0.26 (4.13%) | 0.24 (2.07%) | 0.017 (3.2%) | |
| MDC (mm) | 0.740 | 0.665 | 0.047 | |
| ICC | 0.929 | 0.933 | 0.882 | |
| Observer 2 | 95% CI | 0.892-0.953 | 0.899-0.956 | 0.824-0.923 |
| SEM (mm) | 0.18 (2.77%) | 0.28 (2.37%) | 0.022 (4%) | |
| MDC (mm) | 0.498 | 0.770 | 0.060 | |
| ICC | 0.916 | 0.943 | 0.790 | |
| Inter-rater | 95% CI | 0.873-0.945 | 0.914-0.963 | 0.693-0.853 |
| SEM (mm) | 0.19 (2.13%) | 0.243 (2.06%) | 0.028 (5.18%) | |
| MDC (mm) | 0.526 | 0.673 | 0.077 | |
| SsT: Supraspinatus tendon; AHD: Acromiohumeral distance; ICC: Intraclass correlation coefficients; CI: Confidence interval; SEM: Standard error of mean; MDC: Minimum detectable change. | ||||