Evaluation of diffusion-weighted MRI and geometric distortion on a 0.35T MR-LINAC at multiple gantry angles.

Benjamin Lewis1, Anamaria Guta1, Stacie Mackey2, H Michael Gach1,3,4, Sasa Mutic1, Olga Green1, Taeho Kim1.   

Abstract

Diffusion-weighted imaging (DWI) provides a valuable diagnostic tool for tumor evaluation. Yet, it is difficult to acquire daily MRI data sets in the traditional radiotherapy clinical setting due to patient burden and limited resources. However, integrated MRI radiotherapy treatment systems facilitate daily functional MRI acquisitions like DWI during treatment exams. Before ADC values from MR-RT systems can be used clinically their reproducibility and accuracy must be quantified. This study used a NIST traceable DWI phantom to verify ADC values acquired on a 0.35 T MR-LINAC system at multiple gantry angles. A diffusion-weighted echo planar imaging sequence was used for all image acquisitions, with b-values of 0, 500, 900, 2000 s/mm2 for the 1.5 T and 3.0 T systems and 0, 200, 500, 800 s/mm2 for the 0.35 T system. Images were acquired at multiple gantry angles on the MR-LINAC system from 0° to 330° in 30° increments to assess the impact of gantry angle on geometric distortion and ADC values. CT images, and three fiducial markers were used as ground truth for geometric distortion measurements. The distance between fiducial markers increased by as much as 7.2 mm on the MR-LINAC at gantry angle 60°. ADC values of deionized water vials from the 1.5 T and 3.0 T systems were 8.30 × 10-6  mm2 /s and -0.85 × 10-6  mm2 /s off, respectively, from the expected value of 1127 × 10-6  mm2 /s. The MR-LINAC system provided an ADC value of the pure water vials that was -116.63 × 10-6  mm2 /s off from the expected value of 1127 × 10-6  mm2 /s. The MR-LINAC also showed a variation in ADC across all gantry angles of 33.72 × 10-6  mm2 /s and 20.41 × 10-6  mm2 /s for the vials with expected values of 1127 × 10-6  mm2 /s and 248 × 10-6  mm2 /s, respectively. This study showed that variation of the ADC values and geometric information on the 0.35 T MR-LINAC system was dependent on the gantry angle at acquisition.
© 2021 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

Entities:  

Keywords:  DWI; MR-LINAC; MRgRT

Mesh:

Year:  2021        PMID: 33450146      PMCID: PMC7882099          DOI: 10.1002/acm2.13135

Source DB:  PubMed          Journal:  J Appl Clin Med Phys        ISSN: 1526-9914            Impact factor:   2.102


  25 in total

1.  Role of conventional and diffusion weighted MRI in predicting treatment response after low dose radiation and chemotherapy in locally advanced carcinoma cervix.

Authors:  Saikat Das; Anuradha Chandramohan; Jeba Karunya Rami Reddy; Sramana Mukhopadhyay; Ramani Manoj Kumar; Rajesh Isiah; Subhashini John; Regi Oommen; Visalakshi Jeyaseelan
Journal:  Radiother Oncol       Date:  2015-10-20       Impact factor: 6.280

2.  Feasibility and accuracy of quantitative imaging on a 1.5 T MR-linear accelerator.

Authors:  Ernst S Kooreman; Petra J van Houdt; Marlies E Nowee; Vivian W J van Pelt; Rob H N Tijssen; Eric S Paulson; Oliver J Gurney-Champion; Jihong Wang; Folkert Koetsveld; Laurens D van Buuren; Leon C Ter Beek; Uulke A van der Heide
Journal:  Radiother Oncol       Date:  2019-01-28       Impact factor: 6.280

3.  The diffusion-weighted magnetic resonance imaging (DWI) predicts the early response of esophageal squamous cell carcinoma to concurrent chemoradiotherapy.

Authors:  Lan Wang; Lihong Liu; Chun Han; Shutang Liu; Hua Tian; Zhensheng Li; Xuejiao Ren; Gaofeng Shi; Qi Wang; Guangda Wang
Journal:  Radiother Oncol       Date:  2016-11-09       Impact factor: 6.280

4.  MRI guided stereotactic radiotherapy for locally advanced pancreatic cancer.

Authors:  Hanne D Heerkens; Marco van Vulpen; Beth Erickson; Onne Reerink; Martijn Pw Intven; Cornelis At van den Berg; I Quintus Molenaar; Frank P Vleggaar; Gert J Meijer
Journal:  Br J Radiol       Date:  2018-07-31       Impact factor: 3.039

5.  The value of diffusion-weighted MRI to evaluate the response to radiochemotherapy for cervical cancer.

Authors:  Fei Kuang; Ziping Yan; Jian Wang; Ziyuan Rao
Journal:  Magn Reson Imaging       Date:  2013-12-27       Impact factor: 2.546

6.  Impact of measurement parameters on apparent diffusion coefficient quantification in diffusion-weighted-magnetic resonance imaging.

Authors:  Holger Schmidt; Sergios Gatidis; Nina F Schwenzer; Petros Martirosian
Journal:  Invest Radiol       Date:  2015-01       Impact factor: 6.016

7.  The ViewRay system: magnetic resonance-guided and controlled radiotherapy.

Authors:  Sasa Mutic; James F Dempsey
Journal:  Semin Radiat Oncol       Date:  2014-07       Impact factor: 5.934

8.  Diffusion changes in a tumor and peritumoral tissue after stereotactic irradiation for brain tumors: possible prediction of treatment response.

Authors:  Noriaki Tomura; Komei Narita; Jun-ichi Izumi; Akira Suzuki; Akira Anbai; Takahiro Otani; Ikuo Sakuma; Satoshi Takahashi; Kazuo Mizoi; Jiro Watarai
Journal:  J Comput Assist Tomogr       Date:  2006 May-Jun       Impact factor: 1.826

9.  MRI-guided tumor tracking in lung cancer radiotherapy.

Authors:  Laura I Cerviño; Jiang Du; Steve B Jiang
Journal:  Phys Med Biol       Date:  2011-05-31       Impact factor: 3.609

10.  Diffusion-weighted magnetic resonance imaging for predicting and detecting early response to chemoradiation therapy of squamous cell carcinomas of the head and neck.

Authors:  Sungheon Kim; Laurie Loevner; Harry Quon; Eric Sherman; Gregory Weinstein; Alex Kilger; Harish Poptani
Journal:  Clin Cancer Res       Date:  2009-02-01       Impact factor: 12.531

View more
  1 in total

Review 1.  Transformational Role of Medical Imaging in (Radiation) Oncology.

Authors:  Catherine Coolens; Matt N Gwilliam; Paula Alcaide-Leon; Isabella Maria de Freitas Faria; Fabio Ynoe de Moraes
Journal:  Cancers (Basel)       Date:  2021-05-23       Impact factor: 6.639

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.