| Literature DB >> 33437713 |
Bhavika Alpesh Bhavsar1, Michelle Vaz1, Kamei Neilalung1, Tanisha Das2, Swarnaditya Majumdar3, Jagriti Talukdar4.
Abstract
CONTEXT: Dentin hypersensitivity (DH) is a very common dilemma and often results in temporary relief by the conventional treatment method. An in vivo comparative study of various methods and materials helps in evaluation of a superior method to provide a long-lasting relief. AIM: The aim of this study was to evaluate the efficacy of diode laser (DL) and Clinpro XT Varnish for managing DH.Entities:
Keywords: Dentin hypersensitivity; diode laser; randomized clinical trial; varnish; visual analog pain scale (VAS)
Year: 2020 PMID: 33437713 PMCID: PMC7791592 DOI: 10.4103/jispcd.JISPCD_356_20
Source DB: PubMed Journal: J Int Soc Prev Community Dent ISSN: 2231-0762
Figure 1Group 1 where diode laser (iLase, Biolase) was used and was directed perpendicularly to the exposed tooth surface where area was irradiated for 30 s: (A) preoperative, (B) tactile stimulus, (C) air stimulus, (D) gingival barrier, (E) initiation, and (F) laser therapy
Figure 2Group 2 where a thin film of the varnish (Clinpro Xt Varnish, 3M ESPE) was used and was painted on the surface with a disposable applicator tip as per the manufacturer’s instructions: (A) preoperative, (B) tactile stimulus, (C) air stimulus, (D) dispense and mix, (E) application, and (F) light cure
Mean difference in VAS for airway syringe stimulus b/w diode laser and Clinpro XT varnish group treated teeth at different time intervals
| Time interval | Group | N | Mean | Standard deviation | Mean difference | ||
|---|---|---|---|---|---|---|---|
| Baseline (A) | DIODE LASER | 20 | 6.57 | 1.859 | 1.526 | 2.830 | .007* |
| CLINPRO XT VARNISH | 20 | 5.05 | 1.676 | ||||
| 15min after treatment (A) | DIODE LASER | 20 | 1.48 | 1.601 | .567 | 1.172 | .248 |
| CLINPRO XT VARNISH | 20 | .91 | 1.571 | ||||
| 1 week after treatment (A) | DIODE LASER | 20 | 1.24 | 1.300 | .420 | 1.076 | .288 |
| CLINPRO XT VARNISH | 20 | .82 | 1.259 | ||||
| 3 weeks after treatment (A) | DIODE LASER | 20 | .33 | .483 | .333 | 3.239 | .002* |
| CLINPRO XT VARNISH | 20 | .00 | .000 |
*P < 0.05 (significant)
Mean difference in VAS for tactile stimulus b/w diode laser and Clinpro XT varnish group treated teeth at different time intervals
| Time interval | Group | Mean | Standard deviation | Mean difference | |||
|---|---|---|---|---|---|---|---|
| Baseline (T) | DIODE LASER | 20 | 1.24 | 1.868 | 1.238 | 3.110 | .003* |
| CLINPRO XT VARNISH | 20 | .00 | .000 | ||||
| 15min after treatment (T) | DIODE LASER | 20 | .05 | .218 | .048 | 1.024 | .312 |
| CLINPRO XT VARNISH | 20 | .00 | .000 | ||||
| 1 week after treatment (T) | DIODE LASER | 20 | .05 | .218 | .048 | 1.024 | .312 |
| CLINPRO XT VARNISH | 20 | .00 | .000 | ||||
| 3 weeks after treatment (T) | DIODE LASER | 20 | .00 | .000a | 0.0 | 0.0 | NA** |
| CLINPRO XT VARNISH | 20 | .00 | .000a |
**It cannot be computed because the standard deviations of both groups are 0
*P < 0.05 (significant)