Literature DB >> 33430206

Effective Orifice Area of Balloon-Expandable and Self-Expandable Transcatheter Aortic Valve Prostheses: An Echo Doppler Comparative Study.

Mohamad Kanso1, Marion Kibler1, Sebastien Hess1, Jérome Rischner2, Philoktimon Plastaras2, Michel Kindo1, Minh Hoang1, Fabien De Poli3, Pierre Leddet3, Hélène Petit1, Floriane Zeyons1, Annie Trinh1, Kensuke Matsushita1, Olivier Morel1, Patrick Ohlmann1.   

Abstract

Published data on the size-specific effective orifice area (EOA) of transcatheter heart valves (THVs) remain scarce. Here, we sought to investigate the intra-individual changes in EOA and mean transvalvular aortic gradient (MG) of the Sapien 3 (S3), CoreValve (CV), and Evolut R (EVR) prostheses both at short-term and at 1-year follow-up. The study sample consisted of 260 consecutive patients with severe aortic stenosis who underwent transcatheter aortic valve implantation (TAVI). EOAs and MGs were measured with Doppler echocardiography for the following prostheses: S3 23 mm (n = 74; 28.5%), S3 26 mm (n = 67; 25.8%), S3 29 mm (n = 20; 7.7%), CV 23 mm (n = 2; 0.8%), CV 26 mm (n = 15; 5.8%), CV 29 mm (n = 24; 9.2%), CV 31 mm (n = 9; 3.5%), EVR 26 mm (n = 22; 8.5%), and EVR 29 mm (n = 27; 10.4%). Values were obtained at discharge, 1 month, 6 months, and 1 year from implantation. At discharge, EOAs were larger and MGs lower for larger-size prostheses, regardless of being balloon-expandable or self-expandable. In patients with small aortic annulus size, the hemodynamic performances of CV and EVR prostheses were superior to those of S3. However, we did not observe significant differences in terms of all-cause mortality according to THV type or size. Both balloon-expandable and self-expandable new-generation THVs show excellent hemodynamic performances without evidence of very early valve degeneration.

Entities:  

Keywords:  CoreValve; Doppler echocardiography; Edwards Sapien 3; TAVI; effective orifice area; transvalvular gradient

Year:  2021        PMID: 33430206      PMCID: PMC7825656          DOI: 10.3390/jcm10020186

Source DB:  PubMed          Journal:  J Clin Med        ISSN: 2077-0383            Impact factor:   4.241


  22 in total

1.  Flow characteristics of the SAPIEN aortic valve: the importance of recognizing in-stent flow acceleration for the echocardiographic assessment of valve function.

Authors:  Sofia Shames; Agnes Koczo; Rebecca Hahn; Zhezhen Jin; Michael H Picard; Linda D Gillam
Journal:  J Am Soc Echocardiogr       Date:  2012-03-17       Impact factor: 5.251

2.  Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice.

Authors:  Helmut Baumgartner; Judy Hung; Javier Bermejo; John B Chambers; Arturo Evangelista; Brian P Griffin; Bernard Iung; Catherine M Otto; Patricia A Pellikka; Miguel Quiñones
Journal:  J Am Soc Echocardiogr       Date:  2009-01       Impact factor: 5.251

3.  Long-term Doppler hemodynamics and effective orifice areas of Edwards SAPIEN and medtronic CoreValve prostheses after TAVI.

Authors:  Sebastian Spethmann; Henryk Dreger; Gerd Baldenhofer; Eyleen Pflug; Wasiem Sanad; Verena Stangl; Gert Baumann; Herko Grubitzsch; Michael Sander; Karl Stangl; Michael Laule; Fabian Knebel
Journal:  Echocardiography       Date:  2013-09-24       Impact factor: 1.724

4.  Effective orifice area and hemodynamic performance of the transcatheter Edwards Sapien 3 prosthesis: short-term and 1-year follow-up.

Authors:  Mischa Külling; Jeremy Külling; Christophe Wyss; David Hürlimann; Ivano Reho; Sacha Salzberg; Ines Bühler; Georg Noll; Jürg Grünenfelder; Roberto Corti; Patric Biaggi
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2018-01-01       Impact factor: 6.875

5.  Early Clinical Outcomes After Transcatheter Aortic Valve Replacement Using a Novel Self-Expanding Bioprosthesis in Patients With Severe Aortic Stenosis Who Are Suboptimal for Surgery: Results of the Evolut R U.S. Study.

Authors:  Jeffrey J Popma; Michael J Reardon; Kamal Khabbaz; J Kevin Harrison; G Chad Hughes; Susheel Kodali; Isaac George; G Michael Deeb; Stan Chetcuti; Robert Kipperman; John Brown; Hongyan Qiao; James Slater; Mathew R Williams
Journal:  JACC Cardiovasc Interv       Date:  2017-02-13       Impact factor: 11.195

6.  Incidence and clinical outcome of prosthesis-patient mismatch after transcatheter aortic valve implantation with the CoreValve prosthesis.

Authors:  Antonio J Muñoz-García; Manuel Muñoz-García; Fernando Carrasco-Chinchilla; María J Molina-Mora; Isabel Rodríguez-Bailón; Antonio J Domínguez-Franco; Manuel F Jiménez-Navarro; Juan H Alonso-Briales; Juan J Gómez-Doblas; José M Hernández-García; Eduardo de Teresa-Galván
Journal:  Int J Cardiol       Date:  2012-11-17       Impact factor: 4.164

7.  2017 ESC/EACTS Guidelines for the management of valvular heart disease.

Authors:  Helmut Baumgartner; Volkmar Falk; Jeroen J Bax; Michele De Bonis; Christian Hamm; Per Johan Holm; Bernard Iung; Patrizio Lancellotti; Emmanuel Lansac; Daniel Rodriguez Muñoz; Raphael Rosenhek; Johan Sjögren; Pilar Tornos Mas; Alec Vahanian; Thomas Walther; Olaf Wendler; Stephan Windecker; Jose Luis Zamorano
Journal:  Eur Heart J       Date:  2017-09-21       Impact factor: 29.983

8.  1-Year Outcomes With the Evolut R Self-Expanding Transcatheter Aortic Valve: From the International FORWARD Study.

Authors:  Ganesh Manoharan; Nicolas M Van Mieghem; Stephan Windecker; Johan Bosmans; Sabine Bleiziffer; Thomas Modine; Axel Linke; Werner Scholtz; Bernard Chevalier; Robert Gooley; Cathy Zeng; Jae K Oh; Eberhard Grube
Journal:  JACC Cardiovasc Interv       Date:  2018-11-26       Impact factor: 11.195

9.  Validation and characterization of transcatheter aortic valve effective orifice area measured by Doppler echocardiography.

Authors:  Marie-Annick Clavel; Josep Rodés-Cabau; Éric Dumont; Rodrigo Bagur; Sébastien Bergeron; Robert De Larochellière; Daniel Doyle; Eric Larose; Jean G Dumesnil; Philippe Pibarot
Journal:  JACC Cardiovasc Imaging       Date:  2011-10

10.  Comparison of the hemodynamic performance of percutaneous and surgical bioprostheses for the treatment of severe aortic stenosis.

Authors:  Marie-Annick Clavel; John G Webb; Philippe Pibarot; Lukas Altwegg; Eric Dumont; Chris Thompson; Robert De Larochellière; Daniel Doyle; Jean-Bernard Masson; Sebastien Bergeron; Olivier F Bertrand; Josep Rodés-Cabau
Journal:  J Am Coll Cardiol       Date:  2009-05-19       Impact factor: 24.094

View more
  2 in total

1.  Hemodynamics of self-expanding versus balloon-expandable transcatheter heart valves in relation to native aortic annulus anatomy.

Authors:  Matti Adam; Victor Mauri; Sarah Schmidt; Vera Fortmeier; Sebastian Ludwig; Hendrik Wienemann; Maria Isabel Körber; Samuel Lee; Max Meertens; Sascha Macherey; Christos Iliadis; Elmar Kuhn; Kaveh Eghbalzadeh; Sabine Bleiziffer; Stephan Baldus; Niklas Schofer; Tanja Katharina Rudolph
Journal:  Clin Res Cardiol       Date:  2022-06-15       Impact factor: 5.460

2.  Procedural Safety and Device Performance of the Portico™ Valve from Experienced TAVI Centers: 30-Day Outcomes in the Multicenter CONFIDENCE Registry.

Authors:  Helge Mollmann; Axel Linke; Luis Nombela-Franco; Martin Sluka; Juan Francisco Oteo Dominguez; Matteo Montorfano; Won-Keun Kim; Martin Arnold; Mariuca Vasa-Nicotera; Lenard Conradi; Anthony Camuglia; Francesco Bedogni; Ganesh Manoharan
Journal:  J Clin Med       Date:  2022-08-18       Impact factor: 4.964

  2 in total