Literature DB >> 22425590

Flow characteristics of the SAPIEN aortic valve: the importance of recognizing in-stent flow acceleration for the echocardiographic assessment of valve function.

Sofia Shames1, Agnes Koczo, Rebecca Hahn, Zhezhen Jin, Michael H Picard, Linda D Gillam.   

Abstract

BACKGROUND: The percutaneously implanted Edwards SAPIEN valve (Edwards Lifesciences, Irvine, CA) consists of cusps mounted within a stent. The individual impact of the stent and cusps on transvalvular flow and its implications for the echocardiographic assessment of valve function have not been previously reported.
METHODS: The study group consisted of 40 patients who underwent successful implantation with the SAPIEN valve. Pulsed Doppler was recorded with sample volumes immediately proximal to the stent (prestent), within the stent but proximal to the cusps (in-stent precusp), and distal to the cusps (in-stent postcusp). The Doppler velocity index and effective orifice area were calculated using both prestent and in-stent precusp velocities to represent "subvalvular" flow and continuous-wave recordings of the left ventricular outflow tract and aortic valve to represent postvalvular flow.
RESULTS: In all patients, there was flow acceleration at two levels: in-stent precusp and in-stent postcusp. The mean in-stent precusp peak velocities were significantly higher than the prestent values (1.5 ± 0.2 vs 1.0 ± 0.2 m/sec, P < .0001). Effective orifice area and Doppler velocity index calculated using the prestent versus in-stent precusp velocities were also significantly different (1.79 ± 0.34 vs 2.54 ± 0.46 cm(2), P < .0001, and 0.48 ± 0.12 vs 0.73 ± 0.13, P < .0001, respectively).
CONCLUSIONS: The SAPIEN valve demonstrates flow acceleration at two levels, representing contributions of both the stent and valve cusps to the total valve gradient. Failure to recognize this phenomenon may result in inappropriate selection of the in-stent precusp pulsed Doppler spectrum to represent "subvalvular" flow, thereby overestimating the effective orifice area and Doppler velocity index.
Copyright © 2012 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22425590     DOI: 10.1016/j.echo.2012.02.013

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  7 in total

Review 1.  Guidance of transcatheter aortic valve replacement by echocardiography.

Authors:  Rebecca T Hahn
Journal:  Curr Cardiol Rep       Date:  2014-01       Impact factor: 2.931

2.  Realistic Vascular Replicator for TAVR Procedures.

Authors:  Oren M Rotman; Brandon Kovarovic; Chander Sadasivan; Luis Gruberg; Baruch B Lieber; Danny Bluestein
Journal:  Cardiovasc Eng Technol       Date:  2018-04-13       Impact factor: 2.495

Review 3.  The most important publications of the past year in echocardiography.

Authors:  A Farkhooy; F A Flachskampf
Journal:  Herz       Date:  2013-02       Impact factor: 1.443

Review 4.  Prosthesis-Patient Mismatch After Aortic Valve Replacement.

Authors:  Abdellaziz Dahou; Haïfa Mahjoub; Philippe Pibarot
Journal:  Curr Treat Options Cardiovasc Med       Date:  2016-11

5.  Validation of methods for effective orifice area measurement of prosthetic valves by two-dimensional and Doppler echocardiography following transcatheter self-expanding aortic valve implantation.

Authors:  Ming-Hu Xiao; Yong-Jian Wu; Jing-Jin Wang; Guang-Yuan Song; Jian-De Wang; Zhen-Hui Zhu; Xu Wang; Zhen-Yan Zhao; Hao Wang
Journal:  J Geriatr Cardiol       Date:  2020-12-28       Impact factor: 3.327

6.  Effective Orifice Area of Balloon-Expandable and Self-Expandable Transcatheter Aortic Valve Prostheses: An Echo Doppler Comparative Study.

Authors:  Mohamad Kanso; Marion Kibler; Sebastien Hess; Jérome Rischner; Philoktimon Plastaras; Michel Kindo; Minh Hoang; Fabien De Poli; Pierre Leddet; Hélène Petit; Floriane Zeyons; Annie Trinh; Kensuke Matsushita; Olivier Morel; Patrick Ohlmann
Journal:  J Clin Med       Date:  2021-01-07       Impact factor: 4.241

7.  Gradient and pressure recovery of a self-expandable transcatheter aortic valve depends on ascending aorta size: In vitro study.

Authors:  Milad Samaee; Hoda Hatoum; Michael Biersmith; Breandan Yeats; Shelley C Gooden; Vinod H Thourani; Rebecca T Hahn; Scott Lilly; Ajit Yoganathan; Lakshmi Prasad Dasi
Journal:  JTCVS Open       Date:  2022-01-22
  7 in total