Literature DB >> 33426801

Spectral CT quantification stability and accuracy for pediatric patients: A phantom study.

Nadav Shapira1, Kai Mei1, Peter B Noël1,2.   

Abstract

BACKGROUND: Spectral computed tomography (spectral CT) provides access to clinically relevant measures of endogenous and exogenous materials in patients. For pediatric patients, current spectral CT applications include lesion characterization, quantitative vascular imaging, assessments of tumor response to treatment, and more.
OBJECTIVE: The aim of this study is a comprehensive investigation of the accuracy and stability of spectral quantifications from a spectral detector-based CT system with respect to different patient sizes and radiation dose levels relevant for the pediatric population.
MATERIALS AND METHODS: A spectral CT phantom with tissue-mimicking materials and iodine concentrations relevant for pediatric imaging was scanned on a spectral detector CT system using a standard pediatric abdominal protocol at 100%, 67%, 33% and 10% of the nominal radiation dose level. Different pediatric patient sizes were simulated using supplemental 3D-printed extension rings. Virtual mono-energetic, iodine density, effective atomic number, and electron density results were analyzed for stability with respect to radiation dose and patient size.
RESULTS: Compared to conventional CT imaging, a pronounced improvement in the stability of attenuation measurements across patient size was observed when using virtual mono-energetic images. Iodine densities were within 0.1 mg/ml, effective atomic numbers were within 0.26 atomic numbers and electron density quantifications were within ±1.0% of their respective nominal values. Relative to the nominal dose clinical protocol, differences in attenuation of all tissue-mimicking materials were maintained below 1.6 HU for a 33% dose reduction, below 2.7 HU for a 67% dose reduction and below 3.7 HU for a 90% dose reduction, for all virtual mono-energetic energies equal to or greater than 50 keV. Iodine, and effective atomic number quantifications were stable to within 0.1 mg/ml and 0.06 atomic numbers, respectively, across all measured dose levels.
CONCLUSION: Spectral CT provides accurate and stable material quantification with respect to radiation dose reduction (up to 90%) and differing pediatric patient size. The observed consistency is an important step towards quantitative pediatric imaging at low radiation exposure levels.
© 2021 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine.

Entities:  

Keywords:  dual energy CT; pediatric imagining; quantitative imaging; spectral CT

Mesh:

Substances:

Year:  2021        PMID: 33426801      PMCID: PMC7984483          DOI: 10.1002/acm2.13161

Source DB:  PubMed          Journal:  J Appl Clin Med Phys        ISSN: 1526-9914            Impact factor:   2.102


  29 in total

1.  First performance evaluation of a dual-source CT (DSCT) system.

Authors:  Thomas G Flohr; Cynthia H McCollough; Herbert Bruder; Martin Petersilka; Klaus Gruber; Christoph Süss; Michael Grasruck; Karl Stierstorfer; Bernhard Krauss; Rainer Raupach; Andrew N Primak; Axel Küttner; Stefan Achenbach; Christoph Becker; Andreas Kopp; Bernd M Ohnesorge
Journal:  Eur Radiol       Date:  2005-12-10       Impact factor: 5.315

2.  Trends in radiation dose and image quality for pediatric patients with a multidetector CT and a third-generation dual-source dual-energy CT.

Authors:  Andrea Agostini; Alberto Mari; Cecilia Lanza; Nicolo' Schicchi; Alessandra Borgheresi; Stefania Maggi; Andrea Giovagnoni
Journal:  Radiol Med       Date:  2019-04-19       Impact factor: 3.469

3.  Image Gently: A Decade of International Collaborations to Promote Appropriate Imaging for Children.

Authors:  Kimberly E Applegate; Donald P Frush
Journal:  J Am Coll Radiol       Date:  2017-07       Impact factor: 5.532

Review 4.  Pediatric CT radiation exposure: where we were, and where we are now.

Authors:  Thomas R Goodman; Adel Mustafa; Erin Rowe
Journal:  Pediatr Radiol       Date:  2019-03-29

5.  Effects of Dual-Energy Technique on Radiation Exposure and Image Quality in Pediatric Body CT.

Authors:  Marilyn J Siegel; Will A Curtis; Juan C Ramirez-Giraldo
Journal:  AJR Am J Roentgenol       Date:  2016-08-04       Impact factor: 3.959

6.  Can dual-energy computed tomography improve visualization of hypoenhancing liver lesions in portal venous phase? Assessment of advanced image-based virtual monoenergetic images.

Authors:  Damiano Caruso; Carlo N De Cecco; U Joseph Schoepf; Amanda R Schaefer; Parker W Leland; Dustin Johnson; Andrea Laghi; Andrew D Hardie
Journal:  Clin Imaging       Date:  2016-10-19       Impact factor: 1.605

Review 7.  Dual-Energy CT of Pediatric Abdominal Oncology Imaging: Private Tour of New Applications of CT Technology.

Authors:  Shawn E Kamps; Jeffrey P Otjen; A Luana Stanescu; Achille Mileto; Edward Y Lee; Grace S Phillips
Journal:  AJR Am J Roentgenol       Date:  2020-03-04       Impact factor: 3.959

Review 8.  Dual-Energy CT in Children: Imaging Algorithms and Clinical Applications.

Authors:  Marilyn J Siegel; Juan Carlos Ramirez-Giraldo
Journal:  Radiology       Date:  2019-03-26       Impact factor: 11.105

9.  Population-based waist circumference and waist-to-height ratio reference values in preschool children.

Authors:  Josefine Roswall; Stefan Bergman; Gerd Almqvist-Tangen; Bernt Alm; Aimon Niklasson; Andreas F M Nierop; Jovanna Dahlgren
Journal:  Acta Paediatr       Date:  2009-07-14       Impact factor: 2.299

10.  Bone mineral density measurements in vertebral specimens and phantoms using dual-layer spectral computed tomography.

Authors:  Kai Mei; Benedikt J Schwaiger; Felix K Kopp; Sebastian Ehn; Alexandra S Gersing; Jan S Kirschke; Daniela Muenzel; Alexander A Fingerle; Ernst J Rummeny; Franz Pfeiffer; Thomas Baum; Peter B Noël
Journal:  Sci Rep       Date:  2017-12-13       Impact factor: 4.379

View more