Literature DB >> 3340659

Comparison of the reliability of the Orthoranger and the standard goniometer for assessing active lower extremity range of motion.

M P Clapper1, S L Wolf.   

Abstract

The purpose of this study were to determine 1) the reliability of the Orthoranger for assessing active lower extremity joint range of motion, 2) specific methods for applying the Orthoranger, and 3) whether a correlation exists between the measurements obtained with the Orthoranger and those obtained with a standard goniometer. Ten men and 10 women, mean ages 28.3 +/- 5.1 and 30.0 +/- 10.1 years, respectively, participated in the study. Random selection was used to determine testing sequences. The Orthoranger and the goniometer were used to measure each joint three times during the five sessions. Results indicated that both instruments were reliable for assessing active lower extremity joint ROM. The goniometer showed greater intraclass correlations and confidence levels for all movements except hip lateral rotation, which demonstrated a higher intraclass correlation for the Orthoranger. In addition, all motions except hip adduction and knee extension demonstrated a positive relationship between instruments. Compared with a manual goniometer, the added costs for purchase and use of the Orthoranger appear to be unnecessary until such time that factors enhancing its inherent reliability are identified.

Entities:  

Mesh:

Year:  1988        PMID: 3340659     DOI: 10.1093/ptj/68.2.214

Source DB:  PubMed          Journal:  Phys Ther        ISSN: 0031-9023


  12 in total

1.  Normative Functional Performance Values in High School Athletes: The Functional Pre-Participation Evaluation Project.

Authors:  James A Onate; Cambrie Starkel; Daniel R Clifton; Thomas M Best; James Borchers; Ajit Chaudhari; R Dawn Comstock; Nelson Cortes; Dustin R Grooms; Jay Hertel; Timothy E Hewett; Meghan Maume Miller; Xueliang Pan; Eric Schussler; Bonnie L Van Lunen
Journal:  J Athl Train       Date:  2018-01-09       Impact factor: 2.860

2.  The effects of cold whirlpool on power, speed, agility, and range of motion.

Authors:  Stephen M Patterson; Brian E Udermann; Scott T Doberstein; David M Reineke
Journal:  J Sports Sci Med       Date:  2008-09-01       Impact factor: 2.988

3.  Knee stability and movement coordination impairments: knee ligament sprain.

Authors:  David S Logerstedt; Lynn Snyder-Mackler; Richard C Ritter; Michael J Axe; Joseph J Godges
Journal:  J Orthop Sports Phys Ther       Date:  2010-04       Impact factor: 4.751

4.  Chiropractic care of a 70-year-old female patient with hip osteoarthritis.

Authors:  Richard G Strunk; Mark Hanses
Journal:  J Chiropr Med       Date:  2011-03

Review 5.  Knee pain and mobility impairments: meniscal and articular cartilage lesions.

Authors:  David S Logerstedt; Lynn Snyder-Mackler; Richard C Ritter; Michael J Axe
Journal:  J Orthop Sports Phys Ther       Date:  2010-06       Impact factor: 4.751

6.  THE RELIABILITY OF A NOVEL HEEL-RISE TEST VERSUS GONIOMETRY TO ASSESS PLANTARFLEXION RANGE OF MOTION.

Authors:  Brandon M Ness; Ramu G Sudhagoni; Hanz Tao; Olivia R Full; Lucas O Seehafer; Chelsie M Walder; Kory Zimney
Journal:  Int J Sports Phys Ther       Date:  2018-02

7.  Gender-Dependent Differences in Hip Range of Motion and Impingement Testing in Asymptomatic College Freshman Athletes.

Authors:  Sylvia Czuppon; Heidi Prather; Devyani M Hunt; Karen Steger-May; Nancy J Bloom; John C Clohisy; Richard Larsen; Marcie Harris-Hayes
Journal:  PM R       Date:  2016-11-10       Impact factor: 2.298

8.  Association of lower extremity range of motion and muscle strength with physical performance of community-dwelling older women.

Authors:  Hungu Jung; Masahiro Yamasaki
Journal:  J Physiol Anthropol       Date:  2016-12-08       Impact factor: 2.867

9.  Normative Values of Physical Examinations Commonly Used for Cerebral Palsy.

Authors:  Seung Jun Moon; Young Choi; Chin Youb Chung; Ki Hyuk Sung; Byung Chae Cho; Myung Ki Chung; Jaeyoung Kim; Mi Sun Yoo; Hyung Min Lee; Moon Seok Park
Journal:  Yonsei Med J       Date:  2017-11       Impact factor: 2.759

10.  Comparison of a New Inertial Sensor Based System with an Optoelectronic Motion Capture System for Motion Analysis of Healthy Human Wrist Joints.

Authors:  Michael Alexander Wirth; Gabriella Fischer; Jorge Verdú; Lisa Reissner; Simone Balocco; Maurizio Calcagni
Journal:  Sensors (Basel)       Date:  2019-12-01       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.