Literature DB >> 29484238

THE RELIABILITY OF A NOVEL HEEL-RISE TEST VERSUS GONIOMETRY TO ASSESS PLANTARFLEXION RANGE OF MOTION.

Brandon M Ness1, Ramu G Sudhagoni1, Hanz Tao1, Olivia R Full1, Lucas O Seehafer1, Chelsie M Walder1, Kory Zimney1.   

Abstract

BACKGROUND: Ankle plantarflexion (PF) active range of motion (ROM) is traditionally assessed in a non-weight-bearing (NWB) position with a universal goniometer. However, a convenient, reliable, low-cost means of assessing functional PF active ROM in a weight-bearing (WB) position has yet to be established.
PURPOSE: To compare the intra- and interrater reliability of PF active ROM measurements obtained from a goniometric NWB assessment, and a functional heel-rise test (FHRT) performed in WB. STUDY
DESIGN: Reliability study.
METHODS: Two physical therapy student examiners, blinded to each other's measurements, assessed PF active ROM through a NWB goniometric technique and a FHRT on all subjects within the same test session. Intra- and interrater reliability values were calculated using an intraclass correlation coefficient (ICC2,1, ICC2,k) and 95% confidence intervals. Standard error of measurement (SEM) and minimal detectable change (MDC) were recorded for each method.
RESULTS: 43 healthy participants (mean ± SD, age: 22.7 ± 1.7 years, height: 1.7 ± 0.1 m, mass: 77.8 ± 17.2 kg) completed testing procedures. The within-session intrarater reliability (ICC2,1) estimates were observed for goniometry (right: 0.96, left: 0.95 - 0.97) and FHRT (right: 0.99, left: 0.99), as well as the interrater reliability (ICC2,k) of goniometry (right: 0.79, left: 0.79) and FHRT (right: 0.79, left: 0.87). Goniometry SEM (3.3 - 3.6 °) and MDC (9.2 - 9.8 °) were observed, in addition to FHRT SEM (0.6 cm) and MDC (1.6 - 1.7 cm). A weak correlation was found between FHRT and goniometric measurements (r = -0.03 - 0.13).
CONCLUSIONS: The FHRT was found to have good to excellent intra- and interrater reliability, similar to goniometric measurement. The lack of agreement between these measurements requires further exploration of a WB assessment of ankle PF active ROM. LEVEL OF EVIDENCE: 2b.

Entities:  

Keywords:  Ankle; functional; heel-rise; plantarflexion; range of motion

Year:  2018        PMID: 29484238      PMCID: PMC5808010     

Source DB:  PubMed          Journal:  Int J Sports Phys Ther        ISSN: 2159-2896


  27 in total

1.  Intra-rater and inter-rater reliability of a weight-bearing lunge measure of ankle dorsiflexion.

Authors:  Kim L Bennell; Richard C Talbot; Henry Wajswelner; Wassana Techovanich; David H Kelly; Andrew J Hall
Journal:  Aust J Physiother       Date:  1998

Review 2.  Posterior ankle impingement in athletes: Pathogenesis, imaging features and differential diagnoses.

Authors:  Daichi Hayashi; Frank W Roemer; Pieter D'Hooghe; Ali Guermazi
Journal:  Eur J Radiol       Date:  2015-07-17       Impact factor: 3.528

Review 3.  A review of intraexaminer and interexaminer reliability of static spinal palpation: a literature synthesis.

Authors:  Michael T Haneline; Morgan Young
Journal:  J Manipulative Physiol Ther       Date:  2009-06       Impact factor: 1.437

4.  A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research.

Authors:  Terry K Koo; Mae Y Li
Journal:  J Chiropr Med       Date:  2016-03-31

5.  Comparison of the reliability of the Orthoranger and the standard goniometer for assessing active lower extremity range of motion.

Authors:  M P Clapper; S L Wolf
Journal:  Phys Ther       Date:  1988-02

6.  Risk factors and prognostic indicators for medial tibial stress syndrome.

Authors:  M H Moen; T Bongers; E W Bakker; W O Zimmermann; A Weir; J L Tol; F J G Backx
Journal:  Scand J Med Sci Sports       Date:  2010-06-18       Impact factor: 4.221

7.  Reliability and validity of the standing heel-rise test.

Authors:  Allison Yocum; Sarah Westcott McCoy; Kristie F Bjornson; Pamela Mullens; Gay Naganuma Burton
Journal:  Phys Occup Ther Pediatr       Date:  2010-08       Impact factor: 2.360

Review 8.  Reliability of physical examination tests for the diagnosis of knee disorders: Evidence from a systematic review.

Authors:  Simon Décary; Philippe Ouellet; Pascal-André Vendittoli; François Desmeules
Journal:  Man Ther       Date:  2016-09-23

9.  Weakness in end-range plantar flexion after Achilles tendon repair.

Authors:  Michael J Mullaney; Malachy P McHugh; Timothy F Tyler; Stephen J Nicholas; Steven J Lee
Journal:  Am J Sports Med       Date:  2006-02-13       Impact factor: 6.202

10.  Calf-raise senior: a new test for assessment of plantar flexor muscle strength in older adults: protocol, validity, and reliability.

Authors:  Helô-Isa André; Filomena Carnide; Edgar Borja; Fátima Ramalho; Rita Santos-Rocha; António P Veloso
Journal:  Clin Interv Aging       Date:  2016-11-15       Impact factor: 4.458

View more
  2 in total

1.  Study protocol for a prospective cohort study identifying risk factors for sport injury in adolescent female football players: the Karolinska football Injury Cohort (KIC).

Authors:  Ulrika Tranaeus; Nathan Weiss; Victor Lyberg; Martin Hagglund; Markus Waldén; Urban Johnson; Martin Asker; Eva Skillgate
Journal:  BMJ Open       Date:  2022-01-12       Impact factor: 2.692

2.  THE MANAGEMENT OF PLANTAR FASCIITIS WITH A MUSCULOSKELETAL ULTRASOUND IMAGING GUIDED APPROACH FOR INSTRUMENT ASSISTED SOFT TISSUE MOBILIZATION IN A RUNNER: A CASE REPORT.

Authors:  Rob Sillevis; Eric Shamus; Brittany Mouttet
Journal:  Int J Sports Phys Ther       Date:  2020-04
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.