Literature DB >> 33399473

Is D-dimer a reliable biomarker compared to ESR and CRP in the diagnosis of periprosthetic joint infection?

Xi Chen1, Hairui Li2, Shibai Zhu1, Yiou Wang1, Wenwei Qian1.   

Abstract

AIMS: The diagnosis of periprosthetic joint infection (PJI) has always been challenging. Recently, D-dimer has become a promising biomarker in diagnosing PJI. However, there is controversy regarding its diagnostic value. We aim to investigate the diagnostic value of D-dimer in comparison to ESR and CRP.
METHODS: PubMed, Embase, and the Cochrane Library were searched in February 2020 to identify articles reporting on the diagnostic value of D-dimer on PJI. Pooled analysis was conducted to investigate the diagnostic value of D-dimer, CRP, and ESR.
RESULTS: Six studies with 1,255 cases were included (374 PJI cases and 881 non-PJI cases). Overall D-dimer showed sensitivity of 0.80 (95% confidence interval (CI) 0.69 to 0.87) and specificity of 0.76 (95% CI 0.63 to 0.86). Sub-group analysis by excluding patients with thrombosis and hyper-coagulation disorders showed sensitivity of 0.82 (95% CI 0.70 to 0.90) and specificity of 0.80 (95% CI 0.70 to 0.88). Serum D-dimer showed sensitivity of 0.85 (95% CI 0.76 to 0.92), specificity of 0.83 (95% CI 0.74 to 0.90). Plasma D-dimer showed sensitivity of 0.67 (95% CI 0.60 to 0.73), specificity of 0.58 (95% CI 0.45 to 0.72). CRP showed sensitivity of 0.78 (95% CI 0.72 to 0.83), specificity of 0.81 (95% CI 0.72 to 0.87). ESR showed sensitivity of 0.68 (95% CI 0.63 to 0.73), specificity of 0.83 (95% CI 0.78 to 0.87).
CONCLUSION: In patients without thrombosis or a hyper-coagulation disorder, D-dimer has a higher diagnostic value compared to CRP and ESR. In patients with the aforementioned conditions, D-dimer has higher sensitivity but lower specificity compared to ESR and CRP. We do not recommend the use of serum D-dimer in patients with thrombosis and hyper-coagulation disorders for diagnosing PJI. Serum D-dimer may perform better than plasma D-dimer. Further studies are needed to compare serum D-dimer and plasma D-dimer in arthroplasty patients. Cite this article: Bone Joint Res 2020;9(10):701-708.

Entities:  

Keywords:  D-dimer; Periprosthetic joint infection

Year:  2020        PMID: 33399473     DOI: 10.1302/2046-3758.910.BJR-2020-0172.R2

Source DB:  PubMed          Journal:  Bone Joint Res        ISSN: 2046-3758            Impact factor:   5.853


  6 in total

1.  Limited value of coagulation parameters in diagnosing periprosthetic joint infection.

Authors:  Xia Chen; Jie Xie; Yanming Li; Zijuan Jian; Hongling Li; Qun Yan
Journal:  Int Orthop       Date:  2022-07-05       Impact factor: 3.479

2.  Application of 68Ga-citrate PET/CT for differentiating periprosthetic joint infection from aseptic loosening after joint replacement surgery.

Authors:  Tingting Xu; Yalan Zeng; Xiao Yang; Guangfu Liu; Taiyong Lv; Hongbin Yang; Fei Jiang; Yue Chen
Journal:  Bone Joint Res       Date:  2022-06       Impact factor: 4.410

3.  Different diagnostic performance of plasma fibrinogen and D-dimer in periprosthetic joint infection: a propensity score matched study.

Authors:  Xi Chen; Wenwei Qian; Xisheng Weng; Jin Lin; Jin Jin; Yiou Wang; Shibai Zhu
Journal:  BMC Musculoskelet Disord       Date:  2021-05-07       Impact factor: 2.362

4.  The poor accuracy of D-dimer for the diagnosis of prosthetic joint infection but its potential usefulness in early postoperative infections following revision arthroplasty for aseptic loosening.

Authors:  M Fernandez-Sampedro; I Sanlés-González; C García-Ibarbia; N Fañanás-Rodríquez; M Fakkas-Fernández; M C Fariñas
Journal:  BMC Infect Dis       Date:  2022-01-27       Impact factor: 3.090

5.  Combination of Synovial Fluid IL-4 and Polymorphonuclear Cell Percentage Improves the Diagnostic Accuracy of Chronic Periprosthetic Joint Infection.

Authors:  Jiaxing Huang; Jiawei Wang; Leilei Qin; Bo Zhu; Wei Huang; Ning Hu
Journal:  Front Surg       Date:  2022-03-09

6.  Diagnostic value of platelet indices in infected nonunion: a retrospective study.

Authors:  Zhen Wang; Hai-Jun Mao; Xu-Sheng Qiu; Yi-Xin Chen; Guang-Yue Xu
Journal:  J Orthop Surg Res       Date:  2022-04-04       Impact factor: 2.359

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.