PURPOSE: An increasing number of implantable or external devices can impact whether patients can receive radiological imaging examinations. This study examines and tests the Neulasta (pegfilgrastim) Onpro on-body injector in multiple imaging environments. METHODS: The injector was analyzed for four imaging modalities with testing protocols and strategies developed for each modality. In x-ray and computed tomography (CT), scans with much higher exposure than clinical protocols were performed with the device attached to an anthropomorphic phantom. The device was monitored until the completion of drug delivery. For magnetic resonance imaging (MRI), the device was assessed using a hand-held magnet and underwent the magnetically induced displacement testing in a 1.5T clinical MRI scanner room. For ultrasound, magnetic field changes were measured around an ultrasound scanner system with three transducers. RESULTS: For x-ray and CT no sign of device error was identified during or after the high radiation exposure scans. Drug delivery was completed at expected timing with expected volume. For MRI the device showed significant attractive force towards the hand-held magnet and a 50-degree deflection angle at 50 cm from the opening of the scanner bore. No further assessment from the gradient or radiofrequency field was deemed necessary. For ultrasound the maximum magnetic field change from baseline was measured to be +11.7 μT in comparison to +74.2 μT at 4 inches from a working microwave. CONCLUSIONS: No device performance issue was identified under the extreme test conditions in x-ray or CT. The device was found to be MR Unsafe. Magnetic field changes around an ultrasound system met the limitation set by manufacture. Patient ultrasound scanning is considered safe as long as the transducers do not inadvertently loosen the device.
PURPOSE: An increasing number of implantable or external devices can impact whether patients can receive radiological imaging examinations. This study examines and tests the Neulasta (pegfilgrastim) Onpro on-body injector in multiple imaging environments. METHODS: The injector was analyzed for four imaging modalities with testing protocols and strategies developed for each modality. In x-ray and computed tomography (CT), scans with much higher exposure than clinical protocols were performed with the device attached to an anthropomorphic phantom. The device was monitored until the completion of drug delivery. For magnetic resonance imaging (MRI), the device was assessed using a hand-held magnet and underwent the magnetically induced displacement testing in a 1.5T clinical MRI scanner room. For ultrasound, magnetic field changes were measured around an ultrasound scanner system with three transducers. RESULTS: For x-ray and CT no sign of device error was identified during or after the high radiation exposure scans. Drug delivery was completed at expected timing with expected volume. For MRI the device showed significant attractive force towards the hand-held magnet and a 50-degree deflection angle at 50 cm from the opening of the scanner bore. No further assessment from the gradient or radiofrequency field was deemed necessary. For ultrasound the maximum magnetic field change from baseline was measured to be +11.7 μT in comparison to +74.2 μT at 4 inches from a working microwave. CONCLUSIONS: No device performance issue was identified under the extreme test conditions in x-ray or CT. The device was found to be MR Unsafe. Magnetic field changes around an ultrasound system met the limitation set by manufacture. Patient ultrasound scanning is considered safe as long as the transducers do not inadvertently loosen the device.
Authors: Barry Anthony Boilson; Anita Wokhlu; Nancy G Acker; Joel P Felmlee; Robert E Watson; Paul R Julsrud; Paul A Friedman; Yong-Mei Cha; Robert F Rea; David L Hayes; Win-Kuang Shen Journal: J Interv Card Electrophysiol Date: 2011-09-21 Impact factor: 1.900
Authors: T R Kohler; Y Langlois; G O Roederer; D J Phillips; K W Beach; J Primozich; R Lawrence; S C Nicholls; D E Strandness Journal: Ultrasound Med Biol Date: 1987-10 Impact factor: 2.998
Authors: Deepak Padmanabhan; Danesh K Kella; Ramila Mehta; Suraj Kapa; Abhishek Deshmukh; Siva Mulpuru; Allan S Jaffe; Joel P Felmlee; Mary L Jondal; Connie M Dalzell; Samuel J Asirvatham; Yong-Mei Cha; Robert E Watson; Paul A Friedman Journal: Heart Rhythm Date: 2017-10-16 Impact factor: 6.343
Authors: Ali McBride; Andriy Krendyukov; Nicola Mathieson; Kim Campbell; Sanjeev Balu; Maja Natek; Karen MacDonald; Ivo Abraham Journal: J Med Econ Date: 2019-09-03 Impact factor: 2.448
Authors: Glenn N Levine; Antoinette S Gomes; Andrew E Arai; David A Bluemke; Scott D Flamm; Emanuel Kanal; Warren J Manning; Edward T Martin; J Michael Smith; Norbert Wilke; Frank S Shellock Journal: Circulation Date: 2007-11-19 Impact factor: 29.690
Authors: Zaiyang Long; Michael R Bruesewitz; David R DeLone; Jonathan M Morris; Kimberly K Amrami; Mark C Adkins; Katrina N Glazebrook; James M Kofler; Shuai Leng; Cynthia H McCollough; Joel G Fletcher; Ahmed F Halaweish; Lifeng Yu Journal: J Appl Clin Med Phys Date: 2018-05-10 Impact factor: 2.102