Literature DB >> 21263329

Quantification of liver fat in the presence of iron and iodine: an ex-vivo dual-energy CT study.

Michael A Fischer1, Ralph Gnannt, Dimitri Raptis, Caecilia S Reiner, Pierre-Alain Clavien, Bernhard Schmidt, Sebastian Leschka, Hatem Alkadhi, Robert Goetti.   

Abstract

PURPOSE: Iodinated contrast media (CM) and iron in the liver are known to hinder an accurate quantification of liver fat content (LFC) with single-energy computed tomography (SECT). The purpose of this study was to evaluate the feasibility and accuracy of dual-energy CT (DECT) for ex vivo quantification of LFC, in the presence of iron and CM, compared with SECT.
MATERIALS AND METHODS: Sixteen phantoms with a defined LFC of 0%, 10%, 30%, and 50% fat and with varying iron content (0, 1.5, 3, and 6 mg/mL wet weight liver) were scanned with a second-generation dual-source 128-slice CT system. Phantoms were scanned unenhanced and contrast-enhanced after adding 1.0 mg/mL iodine to each phantom. Both SECT (120 kV) and DECT (tube A: 140 kV, using a tin filter 228 mAs; tube B: 80 kV, 421 mAs) data were acquired. An iron-specific dual-energy 3-material decomposition algorithm providing virtual noniron images (VNI) was used to subtract iron and CM from the data. CT numbers (Hounsfield units) were measured in all data sets, including 120 kV from SECT, as well as 140 kV, 80 kV, 50%:50% weighted 80 kV/140 kV, and VNI derived from DECT. The dual-energy index was calculated from 80 kV and 140 kV data. SECT and DECT measurements (Hounsfield units) including the dual-energy index of unenhanced and contrast-enhanced phantoms were compared with the known titrated LFC, using Pearson correlation analysis and Student t test for related samples.
RESULTS: Inter-reader agreement was excellent for all measurements of CT numbers in both SECT and DECT data (Pearson r, 0.965-1.0). For fat quantification in the absence of iron and CM, CT numbers were similar in SECT and DECT (all, P > 0.05), showing a linear correlation with titrated LFC (r ranging from 0.981 to 0.999; P < 0.01). For fat quantification in the presence of iron but without CM, significant underestimation of LFC was observed for all measurements in SECT and DECT (P < 0.05), except for VNI. Measurements in VNI images allowed for an accurate LFC estimation, with no significant differences compared with measurements in iron-free phantoms (all, P > 0.25). For fat quantification in the presence of iron and CM, further underestimation of LFC was seen for measurements in SECT and DECT (P < 0.015), except for VNI. Measurements in VNI images showed a high accuracy for estimating the LFC, with no significant difference compared with measurements in iron- and CM-free phantoms (P > 0.2).
CONCLUSIONS: Our ex vivo phantom study indicates that DECT with the use of a dedicated, iron-specific 3-material decomposition algorithm allows for the accurate quantification of LFC, even in the presence of iron and iodinated CM. VNI images reconstructed from DECT data equal nonenhanced SECT data of liver without CM by eliminating iron and iodine from the images. No added value was seen for DECT as compared with SECT for quantification of LFC in the absence of iron and iodine.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21263329     DOI: 10.1097/RLI.0b013e31820e1486

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  32 in total

Review 1.  Newer CT applications and their alternatives: what is appropriate in children?

Authors:  R Paul Guillerman
Journal:  Pediatr Radiol       Date:  2011-08-17

Review 2.  Imaging of Cholangiocarcinoma.

Authors:  Susann-Cathrin Olthof; Ahmed Othman; Stephan Clasen; Christina Schraml; Konstantin Nikolaou; Malte Bongers
Journal:  Visc Med       Date:  2016-12-06

3.  Dual-energy CT for liver iron quantification in patients with haematological disorders.

Authors:  Sebastian Werner; Bernhard Krauss; Ulrike Haberland; Malte Bongers; Uwe Starke; Tamam Bakchoul; Sigrid Enkel; Konstantin Nikolaou; Marius Horger
Journal:  Eur Radiol       Date:  2018-11-07       Impact factor: 5.315

Review 4.  Peering through the glare: using dual-energy CT to overcome the problem of metal artefacts in bone radiology.

Authors:  Tyler M Coupal; Paul I Mallinson; Patrick McLaughlin; Savvas Nicolaou; Peter L Munk; Hugue Ouellette
Journal:  Skeletal Radiol       Date:  2014-01-17       Impact factor: 2.199

5.  Specificity of unenhanced CT for non-invasive diagnosis of hepatic steatosis: implications for the investigation of the natural history of incidental steatosis.

Authors:  Perry J Pickhardt; Seong Ho Park; Luke Hahn; Sung-Gyu Lee; Kyongtae T Bae; Eun Sil Yu
Journal:  Eur Radiol       Date:  2011-12-04       Impact factor: 5.315

6.  The correlation between hepatic fat fraction evaluated by dual-energy computed tomography and high-risk coronary plaques in patients with non-alcoholic fatty liver disease.

Authors:  Rui Zhan; Rongxing Qi; Sheng Huang; Yang Lu; Xiaoyu Wang; Jiashen Jiang; Xiwu Ruan; Anyi Song
Journal:  Jpn J Radiol       Date:  2021-04-05       Impact factor: 2.374

Review 7.  Liver fat imaging-a clinical overview of ultrasound, CT, and MR imaging.

Authors:  Yingzhen N Zhang; Kathryn J Fowler; Gavin Hamilton; Jennifer Y Cui; Ethan Z Sy; Michelle Balanay; Jonathan C Hooker; Nikolaus Szeverenyi; Claude B Sirlin
Journal:  Br J Radiol       Date:  2018-06-06       Impact factor: 3.039

Review 8.  Opportunities for new CT contrast agents to maximize the diagnostic potential of emerging spectral CT technologies.

Authors:  Benjamin M Yeh; Paul F FitzGerald; Peter M Edic; Jack W Lambert; Robert E Colborn; Michael E Marino; Paul M Evans; Jeannette C Roberts; Zhen J Wang; Margaret J Wong; Peter J Bonitatibus
Journal:  Adv Drug Deliv Rev       Date:  2016-09-09       Impact factor: 15.470

9.  Quantification of hepatic steatosis with dual-energy computed tomography: comparison with tissue reference standards and quantitative magnetic resonance imaging in the ob/ob mouse.

Authors:  Nathan S Artz; Catherine D G Hines; Stephen T Brunner; Rashmi M Agni; Jens-Peter Kühn; Alejandro Roldan-Alzate; Guang-Hong Chen; Scott B Reeder
Journal:  Invest Radiol       Date:  2012-10       Impact factor: 6.016

Review 10.  Dual-energy CT in diffuse liver disease: is there a role?

Authors:  Khaled Y Elbanna; Bahar Mansoori; Achille Mileto; Patrik Rogalla; Luís S Guimarães
Journal:  Abdom Radiol (NY)       Date:  2020-08-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.