Mikkel Brabrand1,2,3, Søren Bie Bogh4, Marianne Fløjstrup5,6, John Kellett5, Tim Cooksley7, Christian H Nickel8. 1. Department of Emergency Medicine, Hospital of South West Jutland, Finsensgade 35, 6700, Esbjerg, Denmark. mikkel.brabrand@rsyd.dk. 2. Department of Regional Health Research, University of Southern Denmark, Odense, Denmark. mikkel.brabrand@rsyd.dk. 3. Department of Emergency Medicine, Odense University Hospital, Odense, Denmark. mikkel.brabrand@rsyd.dk. 4. Odense Patient Exploratory Network (OPEN), University of Southern Denmark and Odense University Hospital, Odense, Denmark. 5. Department of Emergency Medicine, Hospital of South West Jutland, Finsensgade 35, 6700, Esbjerg, Denmark. 6. Department of Regional Health Research, University of Southern Denmark, Odense, Denmark. 7. Department of Acute Medicine, University Hospital of South Manchester, Manchester, UK. 8. Emergency Department, University Hospital Basel, Basel, Switzerland.
Dear Editor,A normal d-dimer has been advocated as a strong predictor for favorable outcome in unselected patients with a medical emergency [1, 2] and patients with nonspecific complaints [3]. However, there is concern that if d-dimer was measured routinely, there would be an inappropriate increase in investigations to rule-out venous thromboembolic disease (VTE), notwithstanding the increased risk of VTE in COVID-19 [4, 5]. During the current SARS-CoV2 pandemic, 8 out of 22 Danish hospitals have routinely been measuring d-dimer on all patients with suspected SARS-CoV2 infection. This provided an opportunity to explore if this policy resulted in a marked increase in ultrasonography for deep venous thrombosis in the lower extremity, and CT pulmonary angiograms (CTA) and ventilation/perfusion (VQ) scans for pulmonary emboli.Data were obtained from the Danish National Patient Registry on all hospital visits and procedures nationally for patients 18 years or older for the first 17 weeks of 2020 [6]. Difference-in-differences analyses with negative binomial regression models were used to determine if the incidence rate ratios of VTE investigations changed after routine d-dimer measurement was introduced. These analyses accounted for heterogeneity between hospitals and were adjusted for whether they were performed during the pandemic, sex, age, Charlson co-morbidity index, and suspected SARS-CoV2 infection (coded at discharge).The study was approved by the Danish Patient Safety Authority (file no. 20/18426). No informed consent was required.We included 500,873 hospital visits (Table 1). Crude and adjusted differences in incidence rate ratios for changes in use of lower extremity ultrasound were 0.88 (95% CI 0.69–1.12) and 0.89 (95% CI 0.70–1.15), for CTA 0.94 (95% CI 0.76–1.16) and 0.99 (95% CI 0.80–1.21), and for VQ scan 1.33 (95% CI 0.69–2.60) and 1.44 (95%CI 0.74–2.70), respectively.
Table 1
Demographic information on included hospital visits. Data presented as number (%)
D-dimer not routinely measured on hospital level
D-dimer routinely measured on hospital level
n = 300803
n = 200070
Female
170187 (57%)
109804 (55%)
Age
18–49
143191 (48%)
81875 (41%)
50–69
79276 (26%)
56987 (29%)
70 +
78336 (26%)
61208 (31%)
Charlson co-morbidity score
0
180039 (60%)
114815 (57%)
1–2
80843 (27%)
56862 (28%)
3 +
39906 (13%)
28388 (14%)
Suspected SARS-CoV2 infection
20831 (7%)
17510 (9%)
Demographic information on included hospital visits. Data presented as number (%)Our data show that implementing routine measurement of d-dimer on patients suspected of SARS-CoV2 infection did not lead to increased downstream radiological investigations in a population highly representative of those attending Danish emergency departments [7]. There are two potential explanations for this. First, Danish clinicians could be aware of the limitations of d-dimer as stand-alone test and thus only use it is conjunction with a pre-test probability decision rule such as Wells’ criteria [8, 9]. Second, d-dimer was reported as part of a routine panel of tests and could have been used as a marker of disease severity and not just as a screening tool for VTE [10].Yao et al. have shown d-dimer to be a strong prognostic factor in COVID-19 patients in China [11]. We suspect that the same would be the case in our population, but unfortunately, the values of the d-dimer tests were not available to us.This study’s limitation is that the number of d-dimer results reported contemporaneously to the treating physician is unknown. Although, d-dimers were drawn in patients with suspected SARS-CoV2 infection, the incidence of this condition was very low at the time and, therefore, probably did not influence the response to the d-dimer results. Nevertheless, since there was an increase—albeit insignificant—in the number of VQ scans ordered, some physicians must have at least considered the possibility of venous thromboembolic events, which may have been based on awareness of the increased risk of emboli in COVID-19 patients recently reported [6].These results suggest that routine measurement of d-dimers on all-comers to an acute unit will probably not result in an unnecessary increase of radiological investigations.
Authors: Christian H Nickel; John Kellett; Tim Cooksley; Roland Bingisser; Daniel P Henriksen; Mikkel Brabrand Journal: Resuscitation Date: 2016-06-20 Impact factor: 5.262
Authors: P S Wells; D R Anderson; M Rodger; I Stiell; J F Dreyer; D Barnes; M Forgie; G Kovacs; J Ward; M J Kovacs Journal: Ann Intern Med Date: 2001-07-17 Impact factor: 25.391
Authors: Philip S Wells; David R Anderson; Marc Rodger; Melissa Forgie; Clive Kearon; Jonathan Dreyer; George Kovacs; Michael Mitchell; Bernard Lewandowski; Michael J Kovacs Journal: N Engl J Med Date: 2003-09-25 Impact factor: 91.245
Authors: Christian H Nickel; John Kellett; Tim Cooksley; Le E Lyngholm; Simon Chang; Stephan Imfeld; Roland Bingisser; Mikkel Brabrand Journal: Am J Med Date: 2020-07-12 Impact factor: 4.965
Authors: Morten Schmidt; Sigrun Alba Johannesdottir Schmidt; Jakob Lynge Sandegaard; Vera Ehrenstein; Lars Pedersen; Henrik Toft Sørensen Journal: Clin Epidemiol Date: 2015-11-17 Impact factor: 4.790