Literature DB >> 33386885

Biomechanical evaluation of three patellar fixation techniques for MPFL reconstruction: Load to failure did not differ but interference screw stabilization was stiffer than suture anchor and suture-knot fixation.

Vasilios A Raoulis1,2, Aristidis Zibis1, Maria Dimitra Chiotelli3, Alexis T Kermanidis3, Konstantinos Banios1, Philipp Schuster4,5, Michael E Hantes6.   

Abstract

PURPOSE: The purpose of this study was to compare the maximum load to failure and stiffness of three medial patella-femoral ligament (MPFL) reconstruction techniques: (i) suture anchor fixation (SA), (ii) interference screw fixation (SF), and (iii) suture knot (SK) patellar fixation. The null hypothesis was that the comparison between these three different patella fixation techniques would show no difference in the ultimate failure load and stiffness.
METHODS: Reconstruction of the MPFL with gracilis tendon autograft was performed in 12 pairs of fresh-frozen cadaveric knees (24 knees total; mean age, 63.6 [Formula: see text] 8.0 years). The specimens were randomly distributed into 3 groups of 8 specimens; SA reconstruction was completed with two 3.0-mm metal suture anchors; (SF) fixation was accomplished by two 6-mm bio-composite interference screws; SK fixation at the lateral side of the patella was accomplished after drilling two semi-patellar tunnels with a diameter of 4.5 mm. The reconstructions were subjected to cyclic loading for 10 cycles to 30 N and tested to failure at a constant displacement rate of 15 mm/min using a materials-testing machine (MTS 810 Universal Testing System). The final load of failure (N), stiffness (N / mm) and failure mode was recorded in each specimen and followed by statistical analysis.
RESULTS: There was no significant difference in mean ultimate failure load among the three groups. The SK group failed at a mean ([Formula: see text] SD) ultimate load of 253.5 [Formula: see text] 38.2 N, the SA group failed at 243 [Formula: see text] 41.9 N and the SF group at 263.2 [Formula: see text] 9.06 N. The SF group had a mean stiffness of 37.8 [Formula: see text] 5.7 N/mm. This was significantly higher (p < 0.05) than the mean stiffness value achieved for the SK group 21.4 [Formula: see text] 9.5 N/mm and the SA group 18.7 [Formula: see text] 3.4 N/mm. The most common mode of failure in the SA group was anchor pullout, and in the SK group was failure at the graft-suture interface. All the reconstructions in the SF group failed due to tendon graft slippage from the tunnel.
CONCLUSION: Load to failure was not significantly different between the 3 techniques. However, screw fixation was found to be significantly stronger than the anchor and the suture knot fixation in terms of rigidity of the reconstruction. From a clinical point of view, all methods of fixation can be used reliably for MPFL reconstruction, since they were found to be stronger than the native MPFL.

Entities:  

Keywords:  Biomechanical evaluation; Human cadaver specimens; Medial patellofemoral ligament; Patellar fixation

Year:  2021        PMID: 33386885     DOI: 10.1007/s00167-020-06389-4

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  5 in total

1.  [Comparative study of transosseous suture and suture anchor technique in medial patellofemoral ligament double bundle reconstruction].

Authors:  Rui Sun; Mingyi Duan; Xunqi Liu; Siqi Chen; Junyuan Wang; Hangzhou Zhang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2022-01-15

2.  A computed tomography cadaveric study of the radiological anatomy of the patella: the size of the patella correlates with bone bridge between tunnels and R angles are introduced for safe tunnel drilling during MPFL reconstruction.

Authors:  Vasileios Raoulis; Ioannis Tsifountoudis; Apostolos Fyllos; Michael Hantes; Michael-Alexander Malahias; Apostolos Karantanas; Aristeidis Zibis
Journal:  J Exp Orthop       Date:  2021-04-17

3.  Biomechanical Comparison of 2 Patellar Fixation Techniques in Medial Patellofemoral Ligament Reconstruction: Transosseous Sutures vs Suture Anchors.

Authors:  Xin Zhao; Hangzhou Zhang
Journal:  Orthop J Sports Med       Date:  2021-10-19

Review 4.  Hardware-free MPFL reconstruction in patients with recurrent patellofemoral instability is safe and effective.

Authors:  Theodorakys Marín Fermín; Filippo Migliorini; Giorgos Kalifis; Bashir Ahmed Zikria; Pieter D'Hooghe; Khalid Al-Khelaifi; Emmanouil T Papakostas; Nicola Maffulli
Journal:  J Orthop Surg Res       Date:  2022-02-22       Impact factor: 2.359

Review 5.  Interference Screws Are Biomechanically Superior to Suture Anchors for Medial Patellofemoral Ligament Reconstruction: A Systematic Review and Meta-Analysis.

Authors:  Sean B Sequeira; Casey Imbergamo; Heath P Gould
Journal:  Arthrosc Sports Med Rehabil       Date:  2022-06-15
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.