| Literature DB >> 36033175 |
Sean B Sequeira1, Casey Imbergamo1, Heath P Gould1.
Abstract
Purpose: To systematically review the literature to evaluate the biomechanical properties of the interference screw (IS) versus suture anchor (SA) techniques for patellar and femoral fixation of medial patellofemoral ligament (MPFL) reconstruction.Entities:
Year: 2022 PMID: 36033175 PMCID: PMC9402472 DOI: 10.1016/j.asmr.2022.05.003
Source DB: PubMed Journal: Arthrosc Sports Med Rehabil ISSN: 2666-061X
Fig 1Preferred Reporting Items for Systematic Reviews and Meta-Analyses flowchart detailing the database search and inclusion/exclusion process. (MPFL, medial patellofemoral ligament.)
Fixation Details of Included Studies
| Study | Anatomic Fixation | Techniques Compared | Anchors Used | Number of Screws | Number of Anchors | Screws Used | Age, y | Ultimate Load to Failure (N) | Stiffness (N/m) | |
|---|---|---|---|---|---|---|---|---|---|---|
| Raoulis et al., 2021 | Patella | IS, SA | Stryker 3 mm | 2 | 2 | Stryker 6 mm | 16 – 8;8 | 63.66 ± 9.0 y | + | + |
| Joyner et al., 2017 | Patella | IS, SA, suspensory cortical | Bioabsorbable SA, not otherwise specified | 2 | 2 | 6.25 mm × 15 mm or 5.5 mm × 15 mm PEEK | 18 – 9;9 | NR | + | – |
| Mehta et al., 2017 | Patella | Bone tunnels, IS, SA | 2.9-mm PushLock | 2 | 2 | Arthrex 4.75 mm × 15 mm | 30 – 15;15 | NR | + | + |
| Russ et al., 2015 | Patella | IS, SA | 3.0-mm Biocomposite SutureTak SAs, Arthrex | 2 | 2 | 4.75-mm Biocomposite SwiveLock, Arthrex | 16 – 8;8 | 55.8 ± 7.7 y | + | + |
| Lenschow et al., 2013 | Patella | SA, transosseous suture, IS, bone bridge, transpatellar tunnel | 4.75- × 15- mm SwiveLock, Arthrex | 2 | 2 | 6- × 19-mm MegaFix IS | 20 – 10;10 | 28 ± 2 wk | + | + |
| Russo et al., 2016 | Patella | IS, SA, converging tunnel, bone tunnel | 3.5- × 12- mm titanium | 2 | 2 | 4- × 15-mm polyetheretherketone (PEEK) IS | 14 – 7;7 | NR | + | + |
| Johnston et al., 2020 | Femoral | IS, SA | 4.5-mm biocomposite SA, Arthrex | 1 | 1 | 7- × 23-mm biocomposite IS, Arthrex | 18 – 9;9 | NR | + | + |
| Gould et al., 2021 | Femoral | IS, SA | 5.5-mm biocomposite, Arthrex Inc | 1 | 1 | 6-mm biocomposite IS, Arthrex Inc | 12 – 6;6 | 52.8 y | + | + |
| Dobke et al., 2020 | Femoral | IS, SA, adductor tenodesis | 5-mm titanium SA | 1 | 1 | 7 × 25 mm IS | 20 – 10;10 | 8-9 mo | + | – |
IS, interference screw; NR, not reported; PEEK, polyether ether ketone; SA, suture anchor.
Summary of the Methodologic Quality Assessment of Included Studies
| Study | MQAT (%) |
|---|---|
| Raoulis et al., 2021 | 84.6 |
| Joyner et al., 2017 | 84.6 |
| Mehta et al., 2017 | 76.9 |
| Russ et al., 2015 | 84.6 |
| Lenschow et al., 2013 | 84.6 |
| Russo et al., 2016 | 76.9 |
| Johnston et al., 2020 | 84.6 |
| Gould et al., 2021 | 92.3 |
| Dobke et al., 2020 | 76.9 |
MQAT, Methodologic Quality Assessment Tool.
Fig 2Forest plot demonstrating a standardized mean difference of ultimate load to failure in favor of IS MPFL patellar fixation compared with SA. (C.I., confidence interval; IS, interference screw; MPFL, medial patellofemoral ligament; SA, suture anchor.)
Fig 3Forest plot demonstrating a standardized mean difference of stiffness in favor of IS MPFL patellar fixation compared with SA. (C.I., confidence interval; IS, interference screw; MPFL, medial patellofemoral ligament; SA, suture anchor.)
Fig 4Forest plot demonstrating a standardized mean difference of ultimate load to failure in favor of IS MPFL femoral fixation compared with SA. (C.I., confidence interval; IS, interference screw; MPFL, medial patellofemoral ligament; SA, suture anchor.)
Fig 5Forest plot demonstrating a standardized mean difference of stiffness in favor of IS MPFL femoral fixation compared with SA. (C.I., confidence interval; IS, interference screw; MPFL, medial patellofemoral ligament; SA, suture anchor.)