Literature DB >> 23278128

The relationship between resonance frequency analysis (RFA) and lateral displacement of dental implants: an in vitro study.

L Pagliani1, L Sennerby, A Petersson, D Verrocchi, S Volpe, P Andersson.   

Abstract

This in vitro investigation was conducted to study the relationship between resonance frequency analysis (RFA) and lateral displacement measurements of dental implants. A total of 30 implant sites were prepared in nine fresh bovine bone specimens. The bone density around each preparation was determined by using cone beam computerized tomography (CBCT) and imaging software. Dental implants were then inserted during continuous registration of insertion torque. RFA measurements were performed in perpendicular and parallel to the long axis of the specimens. The bone blocks were embedded in plaster and fixated in a specially designed rig for displacement measurements. A lateral force of 25 N was applied via an abutment perpendicular and parallel to each implant and the displacement measured in μm. In addition, a flex constant (μm N(-1) ) was calculated for each measurement. There was a significant inverse correlation between RFA and lateral implant displacement (μm) measurements and between RFA measurements and the flex constant in both perpendicular and parallel directions in bone (P ≤ 0·001). Moreover, both RFA and displacement measurements correlated with bone density (P ≤ 0·001). It is concluded that RFA measurements reflect the micromobility of dental implants, which in turn is determined by the bone density at the implant site.
© 2012 Blackwell Publishing Ltd.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23278128     DOI: 10.1111/joor.12024

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  22 in total

1.  Comparison of the primary stability of orthodontic miniscrews after repeated insertion cycles.

Authors:  Felipe Nenen; Nicolás Garnica; Víctor Rojas; Rodrigo Oyonarte
Journal:  Angle Orthod       Date:  2021-05-01       Impact factor: 2.079

2.  Peri-implant osseointegration after low-level laser therapy: micro-computed tomography and resonance frequency analysis in an animal model.

Authors:  Luciano Mayer; Fernando Vacilotto Gomes; Marília Gerhardt de Oliveira; João Feliz Duarte de Moraes; Lennart Carlsson
Journal:  Lasers Med Sci       Date:  2016-08-17       Impact factor: 3.161

3.  Evaluation of the primary stability in dental implants placed in low density bone with a new drilling technique, Osseodensification: an in vitro study.

Authors:  J Barberá-Millán; C Larrazábal-Morón; J-J Enciso-Ripoll; E Pérez-Pevida; D Chávarri-Prado; M-D Gómez-Adrián
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2021-05-01

4.  Biomechanical evaluation of oversized drilling technique on primary implant stability measured by insertion torque and resonance frequency analysis.

Authors:  Gorka Santamaría-Arrieta; Aritza Brizuela-Velasco; Felipe J Fernández-González; David Chávarri-Prado; Yelko Chento-Valiente; Eneko Solaberrieta; Markel Diéguez-Pereira; José-Antonio Vega; Jaime Yurrebaso-Asúa
Journal:  J Clin Exp Dent       Date:  2016-07-01

Review 5.  Clinical evaluation of osseointegration using resonance frequency analysis.

Authors:  Parth Satwalekar; Sandeep Nalla; Ramaswamy Reddy; Sheeba Glory Chowdary
Journal:  J Indian Prosthodont Soc       Date:  2015 Jul-Sep

6.  A One-year Follow-up Study of a Tapered Hydrophilic Implant Design Using Various Placement Protocols in the Maxilla.

Authors:  Jakob Zwaan; Leonardo Vanden Bogaerde; Herman Sahlin; Lars Sennerby
Journal:  Open Dent J       Date:  2016-12-09

7.  Correlation between Primary, Secondary Stability, Bone Density, Percentage of Vital Bone Formation and Implant Size.

Authors:  Vasilena Ivanova; Ivan Chenchev; Stefan Zlatev; Eitan Mijiritsky
Journal:  Int J Environ Res Public Health       Date:  2021-06-30       Impact factor: 3.390

8.  An ex vivo model in human femoral heads for histopathological study and resonance frequency analysis of dental implant primary stability.

Authors:  Pedro Hernández-Cortés; Alberto Monje; Pablo Galindo-Moreno; Andrés Catena; Inmaculada Ortega-Oller; José Salas-Pérez; Francisco Mesa; Rafael Gómez-Sánchez; Mariano Aguilar; David Aguilar; Francisco O'Valle
Journal:  Biomed Res Int       Date:  2014-06-04       Impact factor: 3.411

9.  A Randomized Case-Series Study Comparing the Stability of Implant with Two Different Surfaces Placed in Fresh Extraction Sockets and Immediately Loaded.

Authors:  Leonardo Vanden Bogaerde; Lars Sennerby
Journal:  Int J Dent       Date:  2016-03-03

10.  ISQ calculation evaluation of in vitro laser scanning vibrometry-captured resonance frequency.

Authors:  Stijn Debruyne; Nicolas Grognard; Gino Verleye; Korneel Van Massenhove; Dimitrios Mavreas; Bart Vande Vannet
Journal:  Int J Implant Dent       Date:  2017-10-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.