Literature DB >> 33353006

Direct and Label-Free Determination of Human Glycated Hemoglobin Levels Using Bacteriorhodopsin as the Biosensor Transducer.

Ying-Chin Lin1,2,3, Ching-Yu Lin4, Hsiu-Mei Chen5, Li-Pin Kuo5, Cheng-En Hsieh5, Xiang-He Wang5, Chih-Wen Cheng5, Chih-Yin Wu3, Yi-Su Chen3.   

Abstract

Glycated hemoglobin (HbA1c) levels are an important index for the diagnosis and long-term control of diabetes. This study is the first to use a direct and label-free photoelectric biosensor to determine HbA1c using bacteriorhodopsin-embedded purple membranes (PM) as a transducer. A biotinylated PM (b-PM) coated electrode that is layered with protein A-oriented antibodies against hemoglobin (Hb) readily captures non-glycated Hb (HbA0) and generates less photocurrent. The spectra of bacteriorhodopsin and Hb overlap so the photocurrent is reduced because of the partial absorption of the incident light by the captured Hb molecules. Two HbA0 and HbA1c aptasensors that are prepared by conjugating specific aptamers on b-PM coated electrodes single-step detect HbA0 and HbA1c in 15 min, without cross reactivity, with detection limits of ≤0.1 μg/mL and a dynamic range of 0.1-100 μg/mL. Both aptasensors exhibit high selectivity and long-term stability. For the clinical samples, HbA0 concentrations and HbA1c levels that are measured with aptasensors correlate well with total Hb concentrations and the HbA1c levels that are determined using standard methods (correlation gradient = 0.915 ± 0.004 and 0.981 ± 0.001, respectively). The use of these aptasensors for diabetes care is demonstrated.

Entities:  

Keywords:  bacteriorhodopsin; glycated hemoglobin; photoelectric biosensor; purple membrane

Mesh:

Substances:

Year:  2020        PMID: 33353006      PMCID: PMC7765918          DOI: 10.3390/s20247274

Source DB:  PubMed          Journal:  Sensors (Basel)        ISSN: 1424-8220            Impact factor:   3.576


  33 in total

1.  Image sensing and processing by a bacteriorhodopsin-based artificial photoreceptor.

Authors:  T Miyasaka; K Koyama
Journal:  Appl Opt       Date:  1993-11-01       Impact factor: 1.980

2.  Effect of graphene oxide on affinity-immobilization of purple membranes on solid supports.

Authors:  Hsiu-Mei Chen; Chi-Jung Lin; Kai-Ru Jheng; Aline Kosasih; Jia-Yaw Chang
Journal:  Colloids Surf B Biointerfaces       Date:  2014-01-31       Impact factor: 5.268

3.  Selection of aptamers specific for glycated hemoglobin and total hemoglobin using on-chip SELEX.

Authors:  Hsin-I Lin; Ching-Chu Wu; Ching-Hsuan Yang; Ko-Wei Chang; Gwo-Bin Lee; Shu-Chu Shiesh
Journal:  Lab Chip       Date:  2015-01-21       Impact factor: 6.799

4.  An integrated microfluidic system for measurement of glycated hemoglobin levels by using an aptamer-antibody assay on magnetic beads.

Authors:  Ko-Wei Chang; Jinglun Li; Ching-Hsuan Yang; Shu-Chu Shiesh; Gwo-Bin Lee
Journal:  Biosens Bioelectron       Date:  2015-01-13       Impact factor: 10.618

5.  Structure of hemoglobin AIc: nature of the N-terminal beta chain blocking group.

Authors:  R M Bookchin; P M Gallop
Journal:  Biochem Biophys Res Commun       Date:  1968-07-11       Impact factor: 3.575

6.  A disposable amperometric dual-sensor for the detection of hemoglobin and glycated hemoglobin in a finger prick blood sample.

Authors:  Jong-Min Moon; Dong-Min Kim; Moo Hyun Kim; Jin-Yeong Han; Dong-Keun Jung; Yoon-Bo Shim
Journal:  Biosens Bioelectron       Date:  2016-12-15       Impact factor: 10.618

Review 7.  HbA1c: a review of analytical and clinical aspects.

Authors:  Cas Weykamp
Journal:  Ann Lab Med       Date:  2013-10-17       Impact factor: 3.464

Review 8.  Recent Progress in Electrochemical HbA1c Sensors: A Review.

Authors:  Baozhen Wang; Jun-Ichi Anzai
Journal:  Materials (Basel)       Date:  2015-03-17       Impact factor: 3.623

9.  Versatile Protein-A Coated Photoelectric Immunosensors with a Purple-Membrane Monolayer Transducer Fabricated by Affinity-Immobilization on a Graphene-Oxide Complexed Linker and by Shear Flow.

Authors:  Hsueh-Hsia Wu; Xin-Quan Liao; Xin-Ying Wu; Cheng-De Lin; Kai-Ru Jheng; Hong-Ren Chen; Yong-Yi Wang; Hsiu-Mei Chen
Journal:  Sensors (Basel)       Date:  2018-12-18       Impact factor: 3.576

10.  An In-Vitro Optical Sensor Designed to Estimate Glycated Hemoglobin Levels.

Authors:  Sanghamitra Mandal; M O Manasreh
Journal:  Sensors (Basel)       Date:  2018-04-04       Impact factor: 3.576

View more
  4 in total

1.  The Combination Clinical Value of Plasma Brain Natriuretic Peptide and Serum HbAlc in the Diagnosis of Chronic Pulmonary Heart Disease.

Authors:  Enxia Jia
Journal:  Comput Math Methods Med       Date:  2022-06-20       Impact factor: 2.809

2.  A Light-Driven Integrated Bio-Capacitor with Single Nano-Channel Modulation.

Authors:  Jie Lin; Yu-Jia Lv; Lei Han; Kuan Sun; Yan Xiang; Xiao-Xing Xing; Yu-Tao Li
Journal:  Nanomaterials (Basel)       Date:  2022-02-09       Impact factor: 5.076

Review 3.  Recent Advances in Electrochemical Aptasensors for Detection of Biomarkers.

Authors:  Marjan Majdinasab; Jean Louis Marty
Journal:  Pharmaceuticals (Basel)       Date:  2022-08-12

4.  Glycated Hemoglobin and Methods for Its Point of Care Testing.

Authors:  Miroslav Pohanka
Journal:  Biosensors (Basel)       Date:  2021-03-04
  4 in total