Literature DB >> 28006679

A disposable amperometric dual-sensor for the detection of hemoglobin and glycated hemoglobin in a finger prick blood sample.

Jong-Min Moon1, Dong-Min Kim1, Moo Hyun Kim2, Jin-Yeong Han2, Dong-Keun Jung2, Yoon-Bo Shim3.   

Abstract

A disposable microfluidic amperometric dual-sensor was developed for the detection of glycated hemoglobin (HbA1C) and total hemoglobin (Hb), separately, in a finger prick blood sample. The accurate level of total Hb was determined through the measurements of the cathodic currents of total Hb catalyzed by a toluidine blue O (TBO)-modified working electrode. Subsequently, after washing unbound Hb in the fluidic channel of dual sensor with PBS, the cathodic current by only HbA1C captured on aptamer was monitored using another aptamer/TBO-modified working electrode in the channel. To modify the sensor probe, poly(2,2´:5´,5″-terthiophene-3´-p-benzoic acid) and a multi-wall carbon nanotube (MWCNT) composite layer (pTBA@MWCNT) was electropolymerized on a screen printed carbon electrode (SPCE), followed by immobilization of TBO for the total Hb probe and aptamer/TBO for the HbA1C probe, respectively. The characterization of each sensor surface was performed using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), X-ray photoelectron spectroscopy (XPS), quartz crystal microbalance (QCM), field-emission scanning electron microscopy (FE-SEM), and transmission electron microscopy (TEM). The experimental conditions affecting the analytical signal were optimized in terms of the amount of TBO, pH, temperature, binding time, applied potential, and the content ratio of monomer and MWCNT. The dynamic ranges of Hb and HbA1C were from 0.1 to 10µM and from 0.006 to 0.74µM, with detection limits of 82(±4.2)nM and 3.7(±0.8)nM, respectively. The reliability of the proposed microfluidic dual-sensor for a finger prick blood sample (1µL) was evaluated in parallel with a conventional method (HPLC) for point-of-care analysis.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Aptamer; Glycated hemoglobin; Hemoglobin; Microfluidic dual-sensor; Toluidine blue O

Mesh:

Substances:

Year:  2016        PMID: 28006679     DOI: 10.1016/j.bios.2016.12.038

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  11 in total

Review 1.  Microfluidic methods for aptamer selection and characterization.

Authors:  Sean K Dembowski; Michael T Bowser
Journal:  Analyst       Date:  2017-12-18       Impact factor: 4.616

Review 2.  Label-free electrochemical microfluidic biosensors: futuristic point-of-care analytical devices for monitoring diseases.

Authors:  Ghasem Ebrahimi; Parvin Samadi Pakchin; Amir Shamloo; Ali Mota; Miguel de la Guardia; Hossein Omidian; Yadollah Omidi
Journal:  Mikrochim Acta       Date:  2022-06-10       Impact factor: 5.833

Review 3.  Label-Free Physical Techniques and Methodologies for Proteins Detection in Microfluidic Biosensor Structures.

Authors:  Georgii Konoplev; Darina Agafonova; Liubov Bakhchova; Nikolay Mukhin; Marharyta Kurachkina; Marc-Peter Schmidt; Nikolay Verlov; Alexander Sidorov; Aleksandr Oseev; Oksana Stepanova; Andrey Kozyrev; Alexander Dmitriev; Soeren Hirsch
Journal:  Biomedicines       Date:  2022-01-18

Review 4.  Emerging Theranostic Nanomaterials in Diabetes and Its Complications.

Authors:  Yuntao Liu; Siqi Zeng; Wei Ji; Huan Yao; Lin Lin; Haiying Cui; Hélder A Santos; Guoqing Pan
Journal:  Adv Sci (Weinh)       Date:  2021-11-25       Impact factor: 16.806

5.  Development of a Soluble KIT Electrochemical Aptasensor for Cancer Theranostics.

Authors:  Saeromi Chung; Jason K Sicklick; Partha Ray; Drew A Hall
Journal:  ACS Sens       Date:  2021-05-19       Impact factor: 9.618

Review 6.  A Review of Electrochemical Sensors for the Detection of Glycated Hemoglobin.

Authors:  Zhikun Zhan; Yang Li; Yuliang Zhao; Hongyu Zhang; Zhen Wang; Boya Fu; Wen Jung Li
Journal:  Biosensors (Basel)       Date:  2022-04-08

Review 7.  Current Status of HbA1c Biosensors.

Authors:  Hua Lin; Jun Yi
Journal:  Sensors (Basel)       Date:  2017-08-04       Impact factor: 3.576

Review 8.  Recent Advances in Electrosynthesized Molecularly Imprinted Polymer Sensing Platforms for Bioanalyte Detection.

Authors:  Robert D Crapnell; Alexander Hudson; Christopher W Foster; Kasper Eersels; Bart van Grinsven; Thomas J Cleij; Craig E Banks; Marloes Peeters
Journal:  Sensors (Basel)       Date:  2019-03-09       Impact factor: 3.576

9.  A Carbon-Based Antifouling Nano-Biosensing Interface for Label-Free POCT of HbA1c.

Authors:  Zhenhua Li; Jianyong Li; Yanzhi Dou; Lihua Wang; Shiping Song
Journal:  Biosensors (Basel)       Date:  2021-04-12

10.  Direct and Label-Free Determination of Human Glycated Hemoglobin Levels Using Bacteriorhodopsin as the Biosensor Transducer.

Authors:  Ying-Chin Lin; Ching-Yu Lin; Hsiu-Mei Chen; Li-Pin Kuo; Cheng-En Hsieh; Xiang-He Wang; Chih-Wen Cheng; Chih-Yin Wu; Yi-Su Chen
Journal:  Sensors (Basel)       Date:  2020-12-18       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.