Literature DB >> 3335087

Alignment and long-term clinical results of a semiconstrained knee prosthesis.

B Jonsson1, J Aström.   

Abstract

In knee arthroplasty, component malpositioning seems to be a fundamental cause for failure. The degree of malpositioning is important. To investigate this degree, 86 of 137 knee arthroplasties performed with the Townley semiconstrained bicondylar prosthesis were examined after a mean follow-up period of 6.5 years (range, 5.0-8.5 years). Five arthroplasties were excluded because of aseptic loosening, but none of these showed malalignment in postoperative roentgenograms. Clinical results and the patients' reports on deterioration of prosthetic function were correlated with positioning of the prosthetic components. Total alignment between 6 degrees of varus and 7 degrees of valgus was associated with good clinical results. Total alignment of more than 7 degrees of valgus, anterior tilting of the tibial component, or positioning of the femoral component in more than 12 degrees of valgus correlated with relatively poor clinical results.

Entities:  

Mesh:

Year:  1988        PMID: 3335087

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  6 in total

1.  [Minimally invasive and navigated implantation for total knee arthroplasty: X-ray analysis and early clinical results].

Authors:  R Hart; M Janecek; I Cizmár; V Stipcák; B Kucera; P Filan
Journal:  Orthopade       Date:  2006-05       Impact factor: 1.087

2.  Assessment and validation of CT scanogram to compare per-operative and post-operative mechanical axis after navigated total knee replacement.

Authors:  Paraskumar Mohanlal; Sunil Jain
Journal:  Int Orthop       Date:  2008-08-12       Impact factor: 3.075

Review 3.  Navigation knee replacement.

Authors:  Rupen Dattani; Surendra Patnaik; Avadhoot Kantak; Georgis Tselentakis
Journal:  Int Orthop       Date:  2008-10-29       Impact factor: 3.075

4.  Efficacy of extramedullary femoral component alignment guide system for blood saving after total knee arthroplasty.

Authors:  Suk Ha Jeon; Ji Hun Kim; Jung Myung Lee; Eun Seok Seo
Journal:  Knee Surg Relat Res       Date:  2012-05-31

5.  Alignment evaluation using different distal reference points after total knee arthroplasty.

Authors:  Yoshinori Ishii; Hideo Noguchi; Junko Sato; Ikuko Takahashi; Hana Ishii; Ryo Ishii; Kei Ishii; Shin-Ichi Toyabe
Journal:  J Orthop       Date:  2021-05-12

6.  Radiologic Outcomes According to Varus Deformity in Minimally Invasive Surgery Total Knee Arthroplasty.

Authors:  Ju Hyung Yoo; Sang Hoon Park; Chang Dong Han; Hyun Cheol Oh; Jun Young Park; Seung Jin Choi
Journal:  Yonsei Med J       Date:  2016-01       Impact factor: 2.759

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.