Literature DB >> 33350767

Cardiovascular outcomes associated with Ultrathin bioresorbable polymer sirolimus eluting stents versus thin, durable polymer everolimus eluting stents following percutaneous coronary intervention in patients with type 2 diabetes mellitus: A meta-analysis of published studies.

Shibing Deng1, Xuying Yi2, Zhiming Tian1.   

Abstract

BACKGROUND: Percutaneous coronary intervention with the new generation drug eluting stents (DES) is 1 among the revascularization procedures required to treat patients with coronary artery disease (CAD). Since late stent thrombosis and silent myocardial infarction are highly associated with type 2 diabetes mellitus (T2DM), an analysis comparing the newer generation DES in this specific subgroup of patients would be scientifically relevant.In this analysis, we aimed to systematically compare the cardiovascular outcomes observed with the ultrathin bioresorbable polymer sirolimus eluting stents (SES) versus thin, durable polymer everolimus eluting stents (EES) following percutaneous coronary intervention in patients with T2DM.
METHODS: Through online databases, relevant studies comparing ultrathin bioresorbable polymer SES versus the durable polymer EES were carefully searched. The cardiovascular outcomes were assessed during a follow-up time period of 1 year and more than 1 year (1-5 years) respectively. This meta-analysis was carried out by the latest version of the RevMan software. Following analysis, the results were represented by odds ratios (OR) with 95% confidence intervals (CI).
RESULTS: A total number of 1967 patients with T2DM were included in this analysis. During a 1 year follow-up time period, target lesion failure (TLF) (OR: 0.59, 95% CI: 0.34-1.02; P = .06, target vessel revascularization (TVR) (OR: 0.97, 95% CI: 0.55-1.70; P = .91) and target lesion revascularization (TLR) (OR: 0.91, 95% CI: 0.44-1.87; P = .79) were similarly observed with ultrathin bioresorbable polymer SES versus the thin, durable polymer EES in these patients with T2DM. Other cardiovascular outcomes including myocardial infarction (MI), major adverse cardiac events, all-cause mortality (OR: 0.72, 95% CI: 0.37-1.40; P = .34), cardiac death and stent thrombosis (OR: 0.85, 95% CI: 0.45-1.62; P = .63) were also similarly observed with these 2 types of new stents. During a follow-up time period above 1 year (1-5 years), still no significant difference was observed in TLF, TVR, TLR, major adverse cardiac events, MI, all-cause mortality, cardiac death and stent thrombosis (OR: 0.62, 95% CI: 0.33-1.16; P = .14).
CONCLUSIONS: The ultrathin bioresorbable polymer SES were similar to the durable polymer EES in these patients with T2DM. These 2 types of new generation stents were comparable in terms of cardiovascular outcomes. Hence, they might be recommended in patients with T2DM. Upcoming trials should be able to confirm this hypothesis.
Copyright © 2020 the Author(s). Published by Wolters Kluwer Health, Inc.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 33350767      PMCID: PMC7769319          DOI: 10.1097/MD.0000000000023810

Source DB:  PubMed          Journal:  Medicine (Baltimore)        ISSN: 0025-7974            Impact factor:   1.817


  18 in total

1.  Critical evaluation of the Newcastle-Ottawa scale for the assessment of the quality of nonrandomized studies in meta-analyses.

Authors:  Andreas Stang
Journal:  Eur J Epidemiol       Date:  2010-07-22       Impact factor: 8.082

Review 2.  A Review on the Effects of New Anti-Diabetic Drugs on Platelet Function.

Authors:  Habib Yaribeygi; Stephen L Atkin; Tannaz Jamialahmadi; Amirhossein Sahebkar
Journal:  Endocr Metab Immune Disord Drug Targets       Date:  2020       Impact factor: 2.895

3.  Comparison of a Novel Biodegradable Polymer Sirolimus-Eluting Stent With a Durable Polymer Everolimus-Eluting Stent: 5-Year Outcomes of the Randomized BIOFLOW-II Trial.

Authors:  Thierry Lefèvre; Michael Haude; Franz-Josef Neumann; Karl Stangl; Carsten Skurk; Ton Slagboom; Manel Sabaté; Javier Goicolea; Paul Barragan; Stéphane Cook; Jean-Christophe Macia; Stephan Windecker
Journal:  JACC Cardiovasc Interv       Date:  2018-05-28       Impact factor: 11.195

4.  Comparison of efficacy and safety between ultrathin bioresorbable polymer sirolimus-eluting stents and thin durable polymer drug-eluting stents: a systematic review and meta-analysis of the literature.

Authors:  Zhen-Yu Zhai; Ju-Xiang Li
Journal:  Coron Artery Dis       Date:  2019-12       Impact factor: 1.439

5.  Ultrathin-strut, biodegradable-polymer, sirolimus-eluting stents versus thin-strut, durable-polymer, everolimus-eluting stents for percutaneous coronary revascularisation: 5-year outcomes of the BIOSCIENCE randomised trial.

Authors:  Thomas Pilgrim; Raffaele Piccolo; Dik Heg; Marco Roffi; David Tüller; Olivier Muller; Igal Moarof; George C M Siontis; Stéphane Cook; Daniel Weilenmann; Christoph Kaiser; Florim Cuculi; Lukas Hunziker; Franz R Eberli; Peter Jüni; Stephan Windecker
Journal:  Lancet       Date:  2018-08-28       Impact factor: 79.321

6.  Unselected Use of Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent for Coronary Revascularization.

Authors:  Kyohei Yamaji; Thomas Zanchin; Christian Zanchin; Stefan Stortecky; Konstantinos C Koskinas; Lukas Hunziker; Fabien Praz; Stefan Blöchlinger; Christina Moro; Aris Moschovitis; Christian Seiler; Marco Valgimigli; Michael Billinger; Thomas Pilgrim; Dik Heg; Stephan Windecker; Lorenz Räber
Journal:  Circ Cardiovasc Interv       Date:  2018-09       Impact factor: 6.546

7.  Subgroup Analysis Comparing Ultrathin, Bioresorbable Polymer Sirolimus-Eluting Stents Versus Thin, Durable Polymer Everolimus-Eluting Stents in Acute Coronary Syndrome Patients.

Authors:  Ariel Roguin; David E Kandzari; Erez Marcusohn; Jacques J Koolen; Gheorghe Doros; Joseph M Massaro; Hector M Garcia-Garcia; Johan Bennett; Elie G Gharib; Donald E Cutlip; Ron Waksman
Journal:  Circ Cardiovasc Interv       Date:  2018-10       Impact factor: 6.546

8.  The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate healthcare interventions: explanation and elaboration.

Authors:  Alessandro Liberati; Douglas G Altman; Jennifer Tetzlaff; Cynthia Mulrow; Peter C Gøtzsche; John P A Ioannidis; Mike Clarke; P J Devereaux; Jos Kleijnen; David Moher
Journal:  BMJ       Date:  2009-07-21

9.  Comparison of the Absorbable Polymer Sirolimus-Eluting Stent (MiStent) to the Durable Polymer Everolimus-Eluting Stent (Xience) (from the DESSOLVE I/II and ISAR-TEST-4 Studies).

Authors:  Alexandra J Lansky; Adnan Kastrati; Elazer R Edelman; Helen Parise; Vivian G Ng; John Ormiston; William Wijns; Robert A Byrne
Journal:  Am J Cardiol       Date:  2015-12-07       Impact factor: 2.778

10.  Revascularisation versus medical treatment in patients with stable coronary artery disease: network meta-analysis.

Authors:  Stephan Windecker; Stefan Stortecky; Giulio G Stefanini; Bruno R da Costa; Bruno R daCosta; Anne Wilhelmina Rutjes; Marcello Di Nisio; Maria G Silletta; Maria G Siletta; Ausilia Maione; Fernando Alfonso; Peter M Clemmensen; Jean-Philippe Collet; Jochen Cremer; Volkmar Falk; Gerasimos Filippatos; Christian Hamm; Stuart Head; Arie Pieter Kappetein; Adnan Kastrati; Juhani Knuuti; Ulf Landmesser; Günther Laufer; Franz-Joseph Neumann; Dimitri Richter; Patrick Schauerte; Miguel Sousa Uva; David P Taggart; Lucia Torracca; Marco Valgimigli; William Wijns; Adam Witkowski; Philippe Kolh; Peter Jüni; Peter Juni
Journal:  BMJ       Date:  2014-06-23
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.