Literature DB >> 29798778

Comparison of a Novel Biodegradable Polymer Sirolimus-Eluting Stent With a Durable Polymer Everolimus-Eluting Stent: 5-Year Outcomes of the Randomized BIOFLOW-II Trial.

Thierry Lefèvre1, Michael Haude2, Franz-Josef Neumann3, Karl Stangl4, Carsten Skurk5, Ton Slagboom6, Manel Sabaté7, Javier Goicolea8, Paul Barragan9, Stéphane Cook10, Jean-Christophe Macia11, Stephan Windecker12.   

Abstract

OBJECTIVES: The authors aimed to compare long-term data of an ultrathin cobalt-chromium stent with passive silicon carbide coating and an active biodegradable polymer that releases sirolimus (O-SES) (Orsiro, BIOTRONIK, Bülach, Switzerland) with the durable polymer-based Xience Prime everolimus-eluting stent (X-EES) (Abbott Vascular, Santa Clara, California).
BACKGROUND: Biodegradable polymer stents have been developed aiming to overcome long-term detrimental effects of durable polymer stents, ultimately leaving a bare-metal stent in the vessel.
METHODS: This multicenter, assessor-blinded trial randomized 452 patients with 505 lesions to either O-SES or X-EES in a 2:1 fashion. Endpoints at 5 years were target lesion failure (TLF), its components, and stent thrombosis.
RESULTS: TLF occurred in 10.4% (n = 30) of O-SES patients versus 12.7% (n = 19) of X-EES patients (p = 0.473), overall stent thrombosis occurred in 0.7% (n = 2) versus 2.8% (n = 4) (p = 0.088), and definite stent thrombosis in 0% versus 0.7% (n = 1) (p = 0.341). Post hoc analysis was performed in diabetic patients (n = 128) and vessels ≤2.75 mm (n = 259). In diabetic patients, the O-SES group had numerically more target lesion revascularizations (13.5% vs. 4.5%; p = 0.138), but fewer cardiac deaths (1.3% vs. 6.9%; p = 0.089) and stent thrombosis (0% vs. 6.9%; p = 0.039). In small vessels, the O-SES group had a significantly lower 5-year mortality (3.7% vs. 11.3%; p = 0.022).
CONCLUSIONS: At 5 years, the biodegradable polymer O-SES demonstrated low TLF rates comparable to the durable polymer X-EES, confirming its long-term safety and performance. Particularly encouraging is the absence of definite stent thrombosis.
Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  biodegradable polymer; coronary artery disease; drug-eluting stent(s); sirolimus

Mesh:

Substances:

Year:  2018        PMID: 29798778     DOI: 10.1016/j.jcin.2018.04.014

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  11 in total

1.  The year in cardiology 2018: coronary interventions.

Authors:  Dariusz Dudek; Artur Dziewierz; Gregg Stone; William Wijns
Journal:  Eur Heart J       Date:  2019-01-07       Impact factor: 29.983

2.  Outcomes in Patients Treated With Thin-Strut, Very Thin-Strut, or Ultrathin-Strut Drug-Eluting Stents in Small Coronary Vessels: A Prespecified Analysis of the Randomized BIO-RESORT Trial.

Authors:  Rosaly A Buiten; Eline H Ploumen; Paolo Zocca; Carine J M Doggen; Liefke C van der Heijden; Marlies M Kok; Peter W Danse; Carl E Schotborgh; Martijn Scholte; Frits H A F de Man; Gerard C M Linssen; Clemens von Birgelen
Journal:  JAMA Cardiol       Date:  2019-07-01       Impact factor: 14.676

3.  Outcomes of patients treated with a biodegradable-polymer sirolimus-eluting stent versus durable-polymer everolimus-eluting stents after rotational atherectomy.

Authors:  Nader Mankerious; Rayyan Hemetsberger; Hussein Traboulsi; Ralph Toelg; Mohamed Abdel-Wahab; Gert Richardt; Abdelhakim Allali
Journal:  Clin Res Cardiol       Date:  2021-04-16       Impact factor: 5.460

4.  Long-term follow-up after ultrathin vs. conventional 2nd-generation drug-eluting stents: a systematic review and meta-analysis of randomized controlled trials.

Authors:  Mahesh V Madhavan; James P Howard; Azim Naqvi; Ori Ben-Yehuda; Bjorn Redfors; Megha Prasad; Bahira Shahim; Martin B Leon; Sripal Bangalore; Gregg W Stone; Yousif Ahmad
Journal:  Eur Heart J       Date:  2021-07-15       Impact factor: 29.983

5.  Thin and crush: The new mantra in left main stenting?

Authors:  Gianluca Rigatelli; Marco Zuin; Debradata Dash
Journal:  World J Cardiol       Date:  2018-11-26

6.  Five-year clinical outcomes of the first Korean-made sirolimus-eluting coronary stent with abluminal biodegradable polymer.

Authors:  Kyoung-Woo Seo; Hyoung-Mo Yang; Junghan Yoon; Hyo-Soo Kim; Kiyuk Chang; Hong-Seok Lim; Byoung-Joo Choi; So-Yeon Choi; Myeong-Ho Yoon; Seung-Hwan Lee; Sung Gyun Ahn; Young Jin Youn; Jun-Won Lee; Bon-Kwon Koo; Kyung Woo Park; Han-Mo Yang; Jung-Kyu Han; Wook-Sung Chung; Hun-Jun Park; Byung-Hee Hwang; Eun-Ho Choo; Gyu-Chul Oh; Seung-Jea Tahk
Journal:  Medicine (Baltimore)       Date:  2021-05-14       Impact factor: 1.889

Review 7.  Understanding the Impact of Stent and Scaffold Material and Strut Design on Coronary Artery Thrombosis from the Basic and Clinical Points of View.

Authors:  Atsushi Sakamoto; Hiroyuki Jinnouchi; Sho Torii; Renu Virmani; Aloke V Finn
Journal:  Bioengineering (Basel)       Date:  2018-09-04

8.  Biodegradable polymer drug-eluting stents versus second-generation drug-eluting stents in patients with and without diabetes mellitus: a single-center study.

Authors:  Xiao-Fang Tang; Yuan-Liang Ma; Ying Song; Jing-Jing Xu; Yi Yao; Chen He; Huan-Huan Wang; Ping Jiang; Lin Jiang; Ru Liu; Zhan Gao; Xue-Yan Zhao; Shu-Bin Qiao; Yue-Jin Yang; Run-Lin Gao; Bo Xu; Jin-Qing Yuan
Journal:  Cardiovasc Diabetol       Date:  2018-08-14       Impact factor: 9.951

9.  Ultrathin-strut biodegradable polymer versus durable polymer drug-eluting stents: a meta-analysis.

Authors:  Mohammad Riashad Monjur; Christian F Said; Paul Bamford; Michael Parkinson; Richard Szirt; Thomas Ford
Journal:  Open Heart       Date:  2020-10

10.  Cardiovascular outcomes associated with Ultrathin bioresorbable polymer sirolimus eluting stents versus thin, durable polymer everolimus eluting stents following percutaneous coronary intervention in patients with type 2 diabetes mellitus: A meta-analysis of published studies.

Authors:  Shibing Deng; Xuying Yi; Zhiming Tian
Journal:  Medicine (Baltimore)       Date:  2020-12-24       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.