Risk of target coverage loss for stereotactic body radiotherapy treatment of synchronous lung lesions via single-isocenter volumetric modulated arc therapy.

Lana C Critchfield1, Mark E Bernard1, Marcus E Randall1, Ronald C McGarry1, Damodar Pokhrel1.   

Abstract

Treating multiple lung lesions synchronously via single-isocenter volumetric modulated arc therapy (VMAT) stereotactic body radiation therapy (SBRT) improves treatment efficiency and patient compliance. However, aligning multiple lung tumors accurately on single pretreatment cone beam CTs (CBCTs) can be problematic. Tumors misaligned could lead to target coverage loss. To quantify this potential target coverage loss due to small, clinically realistic setup errors, a novel simulation method was developed. This method was used on 26 previously treated patients with two metastatic lung lesions. Patients were treated with 4D CT-based, highly conformal noncoplanar VMAT plans (clinical VMAT) with 6MV-flattening filter free (FFF) beam using AcurosXB dose calculation algorithm with heterogeneity corrections. A single isocenter was placed approximately between the lesions to improve patient convenience and clinic workflow. Average isocenter to tumor distance was 5.9 cm. Prescription dose was 54 Gy/50 Gy in 3/5 fractions. For comparison, a plan summation (simulated VMAT) was executed utilizing randomly simulated, clinically relevant setup errors, obtained from pretreatment setup, per treatment fraction, in Eclipse treatment planning system for each of the six degrees of freedom within ± 5.0 mm and ± 2°. Simulations yielded average deviations of 27.4% (up to 72% loss) (P < 0.001) from planned target coverage when treating multiple lung lesions using a single-isocenter plan. The largest deviations from planned coverage and desired biological effective dose (BED10, with α/β = 10 Gy) were seen for the smallest targets (<10 cc), some of which received < 100 Gy BED10. Patient misalignment resulted in substantial decrease in conformity and increase in the gradient index, violating major characteristics of SBRT. Statistically insignificant differences were seen for normal tissue dose. Although, clinical follow-up of these patients is ongoing, the authors recommend an alternative treatment planning strategy to minimize the probability of a geometric miss when treating small lung lesions synchronously with single-isocenter VMAT SBRT plans.
© 2020 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, LLC on behalf of American Association of Physicists in Medicine.

Entities:  

Keywords:  BED10; coverage loss; lung SBRT; setup errors; single-Isocenter VMAT; synchronous

Mesh:

Year:  2020        PMID: 33342042      PMCID: PMC7856510          DOI: 10.1002/acm2.13145

Source DB:  PubMed          Journal:  J Appl Clin Med Phys        ISSN: 1526-9914            Impact factor:   2.102


  25 in total

1.  Validation of a new grid-based Boltzmann equation solver for dose calculation in radiotherapy with photon beams.

Authors:  Oleg N Vassiliev; Todd A Wareing; John McGhee; Gregory Failla; Mohammad R Salehpour; Firas Mourtada
Journal:  Phys Med Biol       Date:  2010-01-07       Impact factor: 3.609

2.  Safety and Efficacy of a Five-Fraction Stereotactic Body Radiotherapy Schedule for Centrally Located Non-Small-Cell Lung Cancer: NRG Oncology/RTOG 0813 Trial.

Authors:  Andrea Bezjak; Rebecca Paulus; Laurie E Gaspar; Robert D Timmerman; William L Straube; William F Ryan; Yolanda I Garces; Anthony T Pu; Anurag K Singh; Gregory M Videtic; Ronald C McGarry; Puneeth Iyengar; Jason R Pantarotto; James J Urbanic; Alexander Y Sun; Megan E Daly; Inga S Grills; Paul Sperduto; Daniel P Normolle; Jeffrey D Bradley; Hak Choy
Journal:  J Clin Oncol       Date:  2019-04-03       Impact factor: 44.544

3.  Cone-beam computed tomography for on-line image guidance of lung stereotactic radiotherapy: localization, verification, and intrafraction tumor position.

Authors:  Thomas G Purdie; Jean-Pierre Bissonnette; Kevin Franks; Andrea Bezjak; David Payne; Fanny Sie; Michael B Sharpe; David A Jaffray
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-02-27       Impact factor: 7.038

4.  Time dependence of intrafraction patient motion assessed by repeat stereoscopic imaging.

Authors:  Mischa S Hoogeman; Joost J Nuyttens; Peter C Levendag; Ben J M Heijmen
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-11-08       Impact factor: 7.038

5.  Quantifying interfraction and intrafraction tumor motion in lung stereotactic body radiotherapy using respiration-correlated cone beam computed tomography.

Authors:  Jean-Pierre Bissonnette; Kevin N Franks; Thomas G Purdie; Douglas J Moseley; Jan-Jakob Sonke; David A Jaffray; Laura A Dawson; Andrea Bezjak
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-04-22       Impact factor: 7.038

6.  Dosimetric effect of translational and rotational errors for patients undergoing image-guided stereotactic body radiotherapy for spinal metastases.

Authors:  He Wang; Almon Shiu; Congjun Wang; Jennifer O'Daniel; Anita Mahajan; Shiao Woo; Praimakorn Liengsawangwong; Radhe Mohan; Eric L Chang
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-05-15       Impact factor: 7.038

7.  Potential reduction of lung dose via VMAT with jaw tracking in the treatment of single-isocenter/two-lesion lung SBRT.

Authors:  Damodar Pokhrel; Lana Sanford; Matthew Halfman; Janelle Molloy
Journal:  J Appl Clin Med Phys       Date:  2019-04-05       Impact factor: 2.102

8.  Improving treatment efficiency via photon optimizer (PO) MLC algorithm for synchronous single-isocenter/multiple-lesions VMAT lung SBRT.

Authors:  Lana Sanford; Damodar Pokhrel
Journal:  J Appl Clin Med Phys       Date:  2019-09-20       Impact factor: 2.102

9.  Treatment Plan Technique and Quality for Single-Isocenter Stereotactic Ablative Radiotherapy of Multiple Lung Lesions with Volumetric-Modulated Arc Therapy or Intensity-Modulated Radiosurgery.

Authors:  Kimmen Quan; Karen M Xu; Ron Lalonde; Zachary D Horne; Mark E Bernard; Chuck McCoy; David A Clump; Steven A Burton; Dwight E Heron
Journal:  Front Oncol       Date:  2015-10-06       Impact factor: 6.244

10.  Frameless stereotactic body radiation therapy for multiple lung metastases.

Authors:  Qilin Li; Jinming Mu; Wendong Gu; Yuan Chen; Zhonghua Ning; Jianxue Jin; Honglei Pei
Journal:  J Appl Clin Med Phys       Date:  2014-07-08       Impact factor: 2.102

View more
  2 in total

1.  Feasibility of using ring-mounted Halcyon Linac for single-isocenter/two-lesion lung stereotactic body radiation therapy.

Authors:  Damodar Pokhrel; Aaron Webster; Richard Mallory; Justin Visak; Mark E Bernard; Ronald C McGarry; Mahesh Kudrimoti
Journal:  J Appl Clin Med Phys       Date:  2022-02-07       Impact factor: 2.243

2.  Automation and integration of a novel restricted single-isocenter stereotactic body radiotherapy (a-RESIST) method for synchronous two lung lesions.

Authors:  Lana Sanford Critchfield; Justin Visak; Mark E Bernard; Marcus E Randall; Ronald C McGarry; Damodar Pokhrel
Journal:  J Appl Clin Med Phys       Date:  2021-05-25       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.